Frequently asqued questions, answers and 

connection diagram for  PNI MAB300  

 

1. Does the battery connect directly to board connectors 8 & 9 ?  What type 
of battery is compatible? Does the board charge battery? 
A: 

You can connect 2 pcs. 12V 7AH, 9AH or other Ah back up battery that are compatible 

with the board. When board  is conected to a 230 V power supply it will keep battery charged. 
When 230V power failure, battery will power the board.  

 
2. What is the connection diagram between Board and IR sensor/photocell ( 
5, 6, 7 connector) 
A: 

You can find diagram below 

 
3. What is the 10 connector from PCB used for? 
A:

 10 connector VCC port is one output power supply terminal with about 24 – 27 V. 

 
4. Maiboard has  COM  and  GND descriptions . Are they the same?  
A:

 Yes  COM = GND 

 
5. How does the 1 & 2 input ports work ? What type of external device can 
control gate through this ports? 
A:

 port 1, 2,3 are for input signal for other open devices, such as push button, GSM module, 

external receiver etc. 
Port 1 --- 2SIDE, this  is the terminal where you can connect an external device to trigger both 
gates  open-stop-close cycle. 
Port 2--  COM  
Port 3-- 1 SIDE, this is the terminal where you can connect an external device to trigger  a 
single gate open-stop-close cycle.  
 

6. Is there a difference between port 1 input and port 4 input ? What type 
of device can be connected to port 4? 
A: 

2SIDE terminal input is for connecting many external devices that will control both gates. 

Port 4  input can receive command from a swipe card terminal, a wired keypad and can also 
only control both gates and  it has a self-close timer.  

 
7. How does port 14 and 16  output work? We need example of NF and NA 
terminal . 
A: 

Port 14 and port 16 is dedicated for you to connect a magnet lock or electric lock. 

COM + port 14 = 24 V Energized when trigered   
COM + port 16 = 24 V Continuous that will be disconected when trigered  
 
 

8. What does the menu: 

"8. Setting the lock time (Pb)"  

refer to? What is it 

used for?   
A:

 It means the lock control time for both outputs 14 and 16 

 
9.  What is the Duty Cycle specification for this device? 
A: 

80% or  around 42000 times / cycles 

 