background image

SE-001 

 
Serial Extender  

User Guide 

 
 

 

 

 

 

 

 

 

 

 

 

F966 
Rev. 20120821 
 

 

 

Customer Service Department 

Summary of Contents for Colorado time systems SE-001

Page 1: ...SE 001 Serial Extender User Guide F966 Rev 20120821 Customer Service Department ...

Page 2: ...www coloradotime com Email customerservice coloradotime com Phone 970 667 1000 x256 Toll Free U S Canada 800 287 0653 x256 Fax 970 667 1032 ...

Page 3: ... 1032 Web www coloradotime com Email customerservice coloradotime com Information in this manual is subject to change without notice Pictures and illustrations may not accurately depict your version Please check our website for the most current information our user manuals are available online in the customer service section of our website F966 Rev 20120821 2012 Colorado Time Systems All rights re...

Page 4: ...er 1 Ports 1 LEDs 2 Dip Switch 2 1 Device A or B 2 2 Link USB and RS232 2 3 Link Test 2 4 Restore Factory Defaults 3 5 Program Mode 3 Programming 3 Uploading Firmware 5 Appendix A Finding COM port numbers 7 Windows 7 Vista XP 7 Method 1 7 Method 2 8 ...

Page 5: ......

Page 6: ...9 pin serial port The SE 001 can get power from the USB port if connected to a 9 pin serial port use the external USB wall adapter to connect to AC power Follow the instructions on the following pages to set up the ports and baud settings for your particular application As a USB to serial converter the SE 001 works alone Simply set dipswitch 2 down and using the appropriate cables connect the USB ...

Page 7: ...S232 When dip switch 2 is set down any data sent on USB will be transmitted via RS232 Data received on RS232 will be sent on USB RS232 and USB are intended for SHORT runs only less than 25 For longer runs use the RS485 link This makes the device a USB to Serial converter if the RS485 is not connected This can be used to connect the System6 COM1 to Meet Manager If active the device creates a star n...

Page 8: ... software you can program the port settings for each of the interfaces The programming connection is only available using the USB port All other ports are inactive during this mode Enter this mode by setting dip switch 5 down All LEDs will be on when entered into this mode The USB LED will flash while communicating with the computer Programming To change internal settings on the device you will ne...

Page 9: ...k that you have the correct COM port Notice the Firmware version and the Current Baud Rates have all filled in 5 You may now change the settings to any combination you wish Set all of the settings to what you want them to be a Warning Most computers do not support baud rates above 115 200kbps 6 Click the Save New Settings button and the settings are sent to the device ...

Page 10: ...sary 1 Place the device into Program Mode by moving dip switch 5 to the DOWN position a All other dip switches are ignored but if dip switch 4 factory reset is down when you reboot all changes will be lost 2 Connect the device to a USB port on the computer a LEDs 1 2 3 should be on solid green 4 will be flashing 3 Open the CTS Serial Device Utility 4 From the Device drop down box select Serial Ext...

Page 11: ...6 ...

Page 12: ...ug the device and re plug to reboot Go back to steps one through four and verify the FW version has updated Once verified move dip switch 5 to the UP position to resume normal operation Appendix A Finding COM port numbers These guides are for identifying COM port numbers in Windows 7 Vista XP The screen shots are done in Windows 7 Method 1 1 Click on the start menu 2 Click Run 3 Type devmgmt msc a...