Страница 1: ...IP based 16 port Metered Power Distribution Unit IPM 16120 ...

Страница 2: ...stered trademarks of their respective holders Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio...

Страница 3: ...t However special attention must be paid to the dangers of electric shock and static electricity when working with electrical equipment All guidelines of this and of the computer manufacture must therefore be allowed at all times to ensure the safe use of the equipment CE Mark Warning This is a Class B product In a domestic environment this product may cause radio interference in which case the us...

Страница 4: ...stallation 14 2 4 Initial Utility Installation 15 Chapter 3 Quick Setup 17 3 1 Network connection 17 3 2 Setup Wizard 17 Chapter 4 Web based Management 21 4 1 Monitor 21 4 2 System 22 4 2 1 Network setting 22 4 2 2 Email Server 24 4 2 3 SMS Server 25 4 2 4 SNMP 26 4 2 5 Syslog 28 4 2 6 Peripheral Parameters 29 4 2 7 Other 30 4 3 Firewall 31 4 3 1 IP Filter 31 4 3 2 MAC filter 32 4 4 Account 32 4 4...

Страница 5: ...IP based 16 port Metered Power Distribution Unit IPM 16120 5 Appendix A Reset to Default via Navigation Button 40 Appendix B HTTP Message API Example 41 ...

Страница 6: ...ediately 1 2 Overview High Voltage Power Distribution Unit with Digital Load Meter PLANET IPM 16120 is a 16 port IP Power Management device that provides premium power protection for your professional workstations and connected devices With the innovative IP based technology PLANET has made the traditional power management equipment into true networking devices The unit comes with a digital load m...

Страница 7: ...rack Electric Current Monitored on Display The aggregate current draw per rack PDU is displayed on the unit via a digital display The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip Remote Management Capabilities Full featured network management interfaces provide standards base...

Страница 8: ...cess configure and manage units from remote locations to save valuable time Overload Protection 16 amp circuit breaker prevents dangerous circuit overloads that could damage equipment The PDU features a built in circuit breaker and reset switch ensuring dependable performance of vital equipment ...

Страница 9: ...l via TCP IP and a built in 10 100Mbps Ethernet port Multi browsers support IE Google Firefox Safari Opera Netscape Management Provides Install Wizard to ease users setting of parameters Events notification by sending pop up message trap or e mail Supports Management Information Base MIB files for SNMP 24 hour power consumption and device temperature monitoring Sets over current watchdog for power...

Страница 10: ...ing There was current overloading Power Distribution Input Power Output Power Voltage 100 240V Frequency 50 60Hz Connection 1 x IEC320 C20 16 x IEC320 C13 Maximum Current 16A Maximum Line Current 10A Cord Length 3 meters Management User Account General Manage Administrator Management Utility Web browser SNMP software Windows base utility Telnet Security IP filter MAC filter Secure 128 bit SSL encr...

Страница 11: ...etered Power Distribution Unit IPM 16120 11 System Unit Operating Temperature 5 45 degrees C Operating Humidity 5 95 Operating Altitude 0 4500 meters Dimensions W x D x H 748 x 43 x 43 mm Weight 1 7kg Installation Zero U ...

Страница 12: ...g panel info and setting parameters Please see below the Panel Operation for more understanding 5 Power Outlet Connect a device to each power outlet to supply power to it Note The max output current is 16 amps 6 Power Inlet Device power lead 7 Circuit Breaker Protection Prevents power overload and damage to devices when circuit breaker protection trips Press the button on the breaker protection to...

Страница 13: ... a long beep sounds to enter alarm current setting 1 For modification of alarm current press to increase the alarm current by 0 5A in each press 2 After increasing to the maximal alarm current the value will return back to 0 5A again and this will cycle 3 Once the alarm current reaches the wanted value hold the five sided button in the middle for 3 seconds until a beep sounds to end the setting Wh...

Страница 14: ...ected systems is within the rated current indicated on the device The test results of this device may be inaccurate giving unstable power supply Avoid using this device in places near water or moisture environments In order to avoid a fire hazard or risk of electric shock do not expose the product to rain or moisture Use the attachments accessories specified by the manufacturer only Please avoid a...

Страница 15: ...f before the installation of the device and take other necessary precautions during the installation 2 4 Initial Utility Installation PLANET IP Search is a software utility used to search the IP Metered PDU product on a network quickly and with ease Step 1 Please download the IP Search tool from PLANET Download Center ...

Страница 16: ...press the Refresh button to find out your IP Metered PDU 1 Before searching the IP please make sure your PC is in the same IP segment as control gateway 2 Do not set double IP addresses on the same LAN card Step 3 Enter the IP address and login to the homepage of IP Metered PDU ...

Страница 17: ...e displayed on the LCD panel or device IP can be searched by IP Search Utility Default DHCP Client On Default IP Address 192 168 0 10 if no DHCP existed in the network Default Port 80 Default Login User Name Set itself Default Login Password Set itself Search Tools ip_search 3 2 Setup Wizard When you use the IPM 16120 for the first time after it is connected to the Internet browser would pop up Se...

Страница 18: ...sword of the device Press Next to continue Step 3 Host Setting The product is assigned dynamically DHCP To specify a fixed IP address please fill in IP Address Subnet Mask and Gateway Press Next to continue Step 4 DNS Setting Key in the DNS server provided by ISP providers and then you can set up two DNS servers Press Next to continue ...

Страница 19: ...u select Http Https both the Http and Https path can be used to access the device Press Next to continue Step 6 Time Format Select the time format to show in the system Press Next to continue Step 7 Time Server Setting User can set up device time synchronized with Time Server Press Next to continue Step 8 Time Zone Please fill in the time zone where the device is The system is based on Greenwich M...

Страница 20: ...bution Unit IPM 16120 20 Step 9 Daylight Saving Time Set the Daylight saving time from Sunday to Saturday Press Next to continue Step 10 General Setting You may set up operational overtime in this section Press Finish to save all settings ...

Страница 21: ...play the following operation menu where each part is illustrated below 1 User login information 2 Reset the logout Time 3 System logout 4 Function bar 5 Voltage V Displays the voltage of the current inlet power Frequency Hz Displays the voltage frequency of the current inlet power Total Current A Displays the currently total power consumption Device Temperature C Displays the current temperature o...

Страница 22: ...than you set the alarm will occur Low Alarm Current Sets up the values of low infeed alarm When the current is lower than you set the alarm will occur High Alarm Device Temperature Sets up the values of high infeed alarm When the current device temperature is higher than you set the alarm will occur Low Alarm Device Temperature Sets up the values of low infeed alarm When the device temperature is ...

Страница 23: ...r the device with the IP address or DNS name is connected to the network Parameters Description Primary DNS Server Configure the IP and DNS server addresses for Network Adapter 1 Secondary DNS Server Configure the IP and DNS server addresses for Network Adapter 2 Parameters Description Enabled Http Allows browser to connect with smart monitor by HTTP Enabled Https Allows browser to connect with sm...

Страница 24: ...s the Host IP address of the e mail sending an alarm e mail when an event occurs Port It is the port of SMTP mail server Default is 25 SMTP TLS secure connection Check to enable e mail encryption From Address It shows the sender s email address Subject It shows the subject of the email Authorization If the mail server needs to identify the user please enable the checkbox and set up the account and...

Страница 25: ...et SMS server Parameters Description Host Host IP address of SMS Server Transmission Mode Follow ISP suppliers rules to send out short message via GET or POST protocol to sender s server Device Name The name user wants to reveal Account The account to fill in when sending SMS The same as ACCOUNT Password The password to fill in when sending SMS The same as PASSWORD Message Format We provide auto b...

Страница 26: ... account to send the message PASSWORD The password to send the message GSMNUM The number to send the message MSG Message content to show as sending a message IP Device IP to show as sending a message Message Format is related to your message content a content may not stay the same as well 4 2 4 SNMP You can set up SNMP Agent and SNMP Trap on this page ...

Страница 27: ...nable SNMP Write in Write Community Key in passwords for the Community Name field Default is private Parameters Description SNMP v3 Enable Enable SNMP v3 User Name The name is SNMP v3 command Type There are two types Read Only Read and Write Authorization Type There are two types MD5 or SHA Authorization Password The password of authorization type Use MD5 or SHA Private Type There are two types No...

Страница 28: ...ts to SNMP Trap Default is 162 Authentication String The authentication string to access SNMP Trap SNMP Test After setting up the above info you can send a test mail to make sure this function is normal 4 2 5 Syslog Remote Power Manager will send out text message to syslog receiver syslog server Please do as follows Parameters Description Host Enter Syslog Server Host IP Port Enter Connect Port fo...

Страница 29: ...em when power current is lower than threshold current Temp Scale You can choose either Celsius or Fahrenheit Released Temp Range You may set up threshold temp to avoid floating power triggered warning reaction The warning will be dismissed by system when temp is lower than threshold temp Parameters Description CO2 Emissions You may set up threshold current to avoid floating power triggered warning...

Страница 30: ...to view LCD panel LCD panel will show the initial picture of the first phase automatically as no operation is processing Timeout In alarm setting status LCD panel will show the initial picture of the first phase automatically as no operation is processing 4 2 7 Other This menu is mainly for setting device web page language operation timeout and device date format Parameters Description Language Tr...

Страница 31: ...MQTT Default is 1883 Parameters Description IP Lock up Period Min The period of such IP has been locked up IP Login Times The number of times that user logs in 4 3 Firewall In this tab you may set up permitted IP or Mac address to access this remote power manager 4 3 1 IP Filter User can set up permitted IP section on this page Parameters Description Enable IP Filter Allow authorized IP address to...

Страница 32: ...store the setting after permitted Mac address is built System will reject people who try to access this remote power manager from other Mac addresses Unmark the square and press the Save button if you expect to cancel this function Allowed MAC Address Enter permitted MAC number Please click ADD to implement this action To delete a specific IP address please click X MAC blocking feature is only ava...

Страница 33: ... utilized any longer 4 4 1 Basic Info To set up account password and user type Parameters Description Account The account to log in this device Password The password to log in this device User Level User authority operation can be grouped into General Manage and Administrator as shown below General Only Switch control is permitted but not authorized to change system settings Manage Parameter setti...

Страница 34: ... email Send To Enter the mail address of Receiver Parameter Use the checkbox to enable the setting The system will follow the warning method you choose Infeed Use the checkbox to enable the setting When abnormal condition of infeed happens system will send a warning message by the way you command Temp Use the checkbox to enable the setting When abnormal device temperature occurs system will send a...

Страница 35: ...e right cellphone number Parameter Use the checkbox to enable the setting The system will follow the warning method you choose Infeed Use the checkbox to enable the setting When abnormal condition of infeed happens system will send a warning message by the way you command Temp Use the checkbox to enable the setting When abnormal device temperature occurs system will send a warning message to manag...

Страница 36: ...anual Setting Synchronization with Time Server Select this time method if you want the system time of this power switch to be the same as Greenwich Mean Time GMT Time Server You can build a new NTP server and then sync with it to be the same date and time If not click Time Server List and choose one from the drop down list Time Zone The time here is following Greenwich Mean Time as most NTP server...

Страница 37: ...to Saturday 4 6 4 6 Chart This menu is mainly for query infeed device temperature and statistic data Parameters Description Category You may either scroll down to select infeed or device temperature Time Interval You may either scroll down to select 1 min or 30 mins Search See the reference date chart as shown in the table Export Download this data chart ...

Страница 38: ...h Click the Refresh button to refresh the screen Download Click teh Download button to save the event log information The event log is saved in txt format Delete Click the Delete button to delete the Event logs 4 8 Upgrade This web page is for upgrading the device firmware and the configuration files You can download the latest firmware from the suppliers web page to upgrade the firmware of IPM se...

Страница 39: ...120 39 Parameters Description Upload firmware To update the firmware online click Browse to select the firmware Then click Upgrade to proceed Upload configuration Upgrade from previous saved setting Download configuration Download the current setting to PC ...

Страница 40: ...p 1 In Network info press the Navigation button for 10 seconds until two beeps sound to enter Set back to factory default values Step 2 Select Reset Account IP admin account and password will be set as admin add a new account if there s no admin account Device IP will be automatically acquired through DHCP if there s no DHCP server the device IP should be preset to 192 168 0 10 The acquired IP is ...

Страница 41: ...tional Tag Description Required depid Company Code Required username User s Account Required password User s password Required dstaddr Objective gate number Separated by commas for delivery to multiple gate numbers repeated gate number is not accepted during each delivery Required IPMbody Message content using standard URL encoding Transform the above format into message server parameters and the ...

Страница 42: ... ACCOUNT The account to send the message PASSWORD The password to send the message GSMNUM The number to send the message MSG Message content to show as sending a message IP Device IP to show as sending a message Message Format Explanation depid xxxxxx username ACCOUNT password PASSWORD dstaddr G SMLWNUM IPMbody IP MSG If you fill the above info in the Message Format the system would automatically ...

Страница 43: ...age format Description Company code depid xxxxxx Required User s Account account ACCOUNT Required User s password password PASSWORD Required Cellphone number dstaddr GSMLWNUM Required Device IP Message content IPMbody IP MSG This format is changeable with the content ...