background image

PMCtendo SZ – EnDat digital

Connection plan-22199-EN-04

Summary of Contents for PMCtendo SZ.3x

Page 1: ...PMCtendo SZ EnDat digital Connection plan 22199 EN 04...

Page 2: ...ing connection errors 3 1 4 Safe functions and EMC of the drive system 4 Section 2 Connection Motor housing to grounding conductor system 5 Section 3 EnDat 2 2 power and feedback plug connectors 6 3 1...

Page 3: ...energized motor Make sure that the motor shaft is stationary during all work A rotat ing rotor can cause high voltages at the connections Disconnect the supply voltage Be aware that there may still be...

Page 4: ...MC requirements mandated by law While commissioning the motor the motor may be damaged or compliance with legal EMC requirements may no longer be possible if you use connec tion cables or servo amplif...

Page 5: ...ne in order to prevent personal injury and faulty triggering of residual current protective devices All attachment parts required for the connection of the grounding conductor to the motor housing are...

Page 6: ...avoid collisions between the motor connection cables and the plug connector of the forced ventilation unit In the event of a collision turn the motor plug connectors accordingly The following images s...

Page 7: ...SZ 83 SZ 85 K con 40 Quick lock 180 40 SZ 85 F con 58 Screw thread 0 0 Features Feedback plug connectors Type Size Connection Turning range SZ 3x con 15 Quick lock 180 120 SZ 4x SZ 5x SZ 7x SZ 82 SZ 8...

Page 8: ...on the size of the motor terminal assignment changes depending on the connector size con 15 connector size Connection diagram Pin Connection Color A 1U1 black B 1V1 blue C 1W1 red 1 2 3 1BR brake DC 2...

Page 9: ...plug connectors Connection plan PMCtendo SZ EnDat digital 22199 EN 04 9 con 58 connector sizes Connection diagram Pin Connection Color U 1U1 black V 1V1 blue W 1W1 red 1BR brake DC 24 V red 1BR brake...

Page 10: ...ring The size of the plug connector depends on the size of the motor the terminal assignment changes depending on the connector size EnDat 2 2 con 15 plug connectors Connection diagram Pin Connection...

Page 11: ...Forced ventilation unit Connection plan PMCtendo SZ EnDat digital 22199 EN 04 11 4 Forced ventilation unit Connection diagram Pin Connection 1 L1 phase 2 N neutral conductor 3 PE...

Page 12: ...istered trademarks of other companies EnDat EnDat and the EnDat logo are registered trademarks of Dr Johannes Heidenhain GmbH Traunreut Germany All other trademarks not listed here are the property of...

Page 13: ...fetyEYE SafetyNET p THE SPIRIT OF SAFETY are registered and protected trademarks of Pilz GmbH Co KG in some countries We would point out that product features may vary from the details stated in this...