USE 

 

The VSR 200 is a voltage-dependent switching isolating relay. It is used for automatic Inter-

connection of two battery groups (e.g. starter / consumer battery or starter / bug battery)bat-

tery) in charging mode.  

 

The VSR 200 measures the voltage of both battery groups at the connection bolts and swit-

ches them together as soon as the voltage at one of the two battery groups is above the 

switch-on threshold. If the charging equipment (alternator, chargers, wind / solar) stops sup-

plying energy, the voltage drops and the relay automatically disconnects the two battery 

groups as soon as the voltage falls below the switch-off threshold. In addition, the battery 

banks can be disconnected during the starting process. 

 

The VSR 200 can be activated in an emergency by manual operation at the relay or by an 

optional control button to establish a connection between the battery groups in order to 

select the motor from both batteries (emergency start function). 

 

The VSR 200 is designed for continuous currents up to 200 A and has a very low self-cur-

rentconsumption.The voltage-dependent switching isolating relay VSR 200 can only be ope-

rated on DC low voltage 9 - 32V.  

 

It is designed for use on yachts or in mobile homes and may only be used in closed rooms 

that are protected from rain, humidity, dust and condensation water. Never use the voltage-

dependent switching isolating relay VSR 200 in places where there is a risk of explosion due 

to gas or dust. It is not suitable for outdoor installation. 

INSTRUCTION MANUAL

Summary of Contents for VSR 200

Page 1: ...y groups as soon as the voltage falls below the switch off threshold In addition the battery banks can be disconnected during the starting process The VSR 200 can be activated in an emergency by manual operation at the relay or by an optional control button to establish a connection between the battery groups in order to select the motor from both batteries emergency start function The VSR 200 is ...

Page 2: ... to the operating instructions and the conditions and methods used during installation use and maintenance of the VSR cannot be supervised by philippi electrical systems gmbh Therefore we do not take any responsibility for loss damage or costs which develop due to incorrect installation and or inappropriate use SAFETY REFERENCES x unauthorized changes to the equipment will invalidate the CE sign x...

Page 3: ...us must be connected to the minus of the on board power supply Terminal C Connection for an optional button for Battery parallel connection against minus Terminal L Connection for an optional external control LED against minus Terminal S Connection for Battery disconnection optional to disconnect the batteries during the start process or during charging with a charger with several outputs or to di...

Page 4: ...t be switched off TECHNICAL DATA Rated voltage 12 V 24 V Operation voltage 9 32 V Rated current continous 200 A Cross section 95 mm Overload 5s 400 A Peak current 0 2 s 1500 A Switch ON Voltage thresholds 120 Sec 13 4 V 26 8 V 30 Sec 13 8 V 27 6 V Switch OFF Voltage thresholds 30 Sec 13 0 V 26 0 V 10 Sec 12 5 V 25 0 V 16 0 V 32 0 V at Over Volatge when C not set Power consumption Relais OFF 1 5 mA...