background image

manual.zwave.eu/backend/make.php?lang=en&sku=PHI_PAN06

1/5

Philio Tech

Relay Insert 2 * 1.5 KW

SKU: PHI_PAN06

Quickstart

This is a 

On/Off Power Switch 

for 

Europe

. To run this device please connect it to your mains power supply.

Tripple Click the Button on the device confirms the inclusion, exclusion and association. After power up it will stay in auto inclusion mode for 4 minutes. To

support handling of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up.

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer,

distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this

equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources. 

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (

two-way communication

) and

every mains powered node can act as a repeater for other nodes (

meshed network

) in case the receiver is

not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be 

used together with any other certified Z-

Wave device regardless of brand and origin 

as long as both are suited for the same frequency range.

If a device supports 

secure communication

 it will communicate with other devices secure as long as this

device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level

of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to 

www.z-wave.info

.

Product Description

This Insert Switch allows controlling two independent loads both wirelessly via Z-Wave and locally utilizing a traditional wall switch. Thanks to its calibration

technology the device cannot only be used to switch resistive devices but also works perfectly with many kind of reactive or resistive loads such as fluorescent

lights or LEDs. The device is placed in a wall box right behind the normal switch. The switch is not longer directly connected to the load but acts as input device for

the insert that is controlling the load. This device is designed for a 3 wire system and needs a neutral wire in the wall box.

Prepare for Installation / Reset

Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it 

must be in factory default state.

 Please make sure to reset the device into factory default. You can do

this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended

to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Tripple Click the button on the device to enter inclusion mode. Within 1 second press the button again for 5 seconds until LED is off.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the

assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Installation

Summary of Contents for PHI PAN06

Page 1: ...security Otherwise it will automatically turn into a lower level of security to maintain backward compatibility For more information about Z Wave technology devices white papers etc please refer to www z wave info Product Description This Insert Switch allows controlling two independent loads both wirelessly via Z Wave and locally utilizing a traditional wall switch Thanks to its calibration techn...

Page 2: ...xternally connected switch Three different modes are supported Edge Mode Die Position of the external switch determines the switching state of the relay After a wireless switching command it may be needed to operate the switch twice to return to the direct relation of switch position and relay state This mode is the factory default mode Toogle Mode Each ON Position of the external switch will togg...

Page 3: ... needs or unlock further enhanced features IMPORTANT Controllers may only allow configuring signed values In order to set values in the range 128 255 the value sent in the application shall be the desired value minus 256 For example To set a parameter to 200 it may be needed to set a value of 200 minus 256 minus 56 In case of a two byte value the same logic applies Values greater than 32768 may nee...

Page 4: ...are Platform SD3502 EAN 4713698571160 IP Class IP 20 Voltage 230 Der Endpunkt3 der Mehrkanal Befehlsklasse bezieht sich auf Relais1 und Relais2 Es kann überflüssig sein die Notwendigkeit Relais1 oder Relais2 einzeln zu steuern Wenn die Existenz von Endpunkt3 als 0 gesetzt ist wird der Endpunkt3 der Mehrkanal Befehlsklasse deaktiviert Load 2x 1500W Device Type On Off Power Switch Generic Device Clas...

Page 5: ... primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to announces that is able to communicate Node Informatio...

Reviews: