Table 1 - PENTEK

®

 Motor Service Factor Amps

Motor Type

PENTEK Part 

Number

Rating @ 

230V

Service Factor 

Amps

HP

2-Wire

P42B0005A2-01

1/2

4.7

P42B0007A2-01

3/4

6.2

P42B0010A2-01

1

8.1

P42B0015A2-01

1-1/2

10.4

P42B0005A2

1/2

4.7

P42B0007A2

3/4

6.4

P42B0010A2

1

9.1

P42B0015A2

1-1/2

11.0

CS/CR 

3-Wire

P43B0005A2-01

1/2

4.8

P43B0007A2-01

3/4

6.0

P43B0010A2-01

1

7.3

P43B0015A2-01

1-1/2

10.9

P43B0005A2

1/2

4.9

P43B0007A2

3/4

6.3

P43B0010A2

1

7.2

P43B0015A2

1-1/2

11.1

P43B0020A2

2

12.2

3-Phase

P43B0005A3

1/2

2.9

P43B0007A3

3/4

3.9

P43B0010A3

1

4.7

P43B0015A3

1-1/2

6.1

P43B0020A3

2

7.6

P43B0030A3

3

10.1

P43B0050A3

5

17.5

Initial Startup: System Start

•  Open valves at the ends of lines to so that air will escape during 

pressurization. Press Auto Start.

•  The Drive will go into Auto Line Fill.
•  Close valves at the ends of lines after all air has escaped.
•  Once the Transducer senses 10 PSI , the Drive will go into Constant Pressure 

Mode and maintain 60 PSI.

•  If a different pressure is required, use PSI Preset to change the setpoint.

6

Initial Startup: Pump Out the Well

Direct the pump’s discharge to an appropriate location not connected to the system and 
press Pump Out. The pump will run at 45 Hz. Adjust frequency as appropriate:
A. Press Enter.
B.  Change frequency value.
 

NOTICE Above ground pumps should run at 60 Hz for this step until pump is primed. 
Then adjust frequency as appropriate.

C. Press Enter again.
 

Run the Drive in this mode until the well discharge runs clear, then press Stop to stop 
the Drive.

 Risk of explosion. Can cause severe injury, property damage or death. In Pump 

Out mode, the pump runs at a constant speed. Restricting flow can cause very high 
pressure. Do not restrict flow.

4

2

Wiring Connections

A.  Disconnect power to the circuit breaker box 

before making any connections.

B.  Connect motor wiring FIRST, transducer cable 

SECOND, and power supply wires LAST. 
Inspect the Drive’s interior. It must be free of 
loose wires and other debris before closing.

C.  Replace the cover and secure it with the 

cover screw before connecting the input 
power cable to the breaker box.

NOTICE When using above ground motor 
rated for use with the PENTEK INTELLIDRIVE, 
maximum lead length is 25 ft. See motor-specific 
user manual and NEC for wire size.

Terminal 

Removable 

(pull down)

01+ 01+   I1+ I1-   I2+ I2-   V+  V-   AI+ AI-   P    N    SD CARD

Transducer Cable 

Connections

Submersible Motor: 3-Ph./ 3-W. 1-Ph., follow colors as above.
Submersible Motor:
 1-Ph./ 2-W., connect to Y and B, any order.
Above-Ground Motors:
 L1 to R, L2 to Y, L3 to B; verify rotation.
 

Output 

Ground Screw

Input Power 
Connections

Input 

Ground Screws

Red

Yellow

Black

Green/Yellow (Ground)

Green/Yellow 

(Ground)

6539 0412

Motor Connections

Red to 

AI

+

Black to 

AI

Green Cable Shield/Screw

Terminal 

Removable 

(pull down)

•  Disconnect power and 

wait 5 minutes before 
opening and removing 
Drive cover.

•  Mount Drive on stud or 

post BEFORE making 
electrical connections.

•  Do not touch Drive with 

wet or damp hands.

•  Disconnect power and 

remove cover with dry 
hands.

Risk of Fire. If installed with 
incorrect circuit breaker 
protection. Install the Drive on 
an independent branch circuit, 
with no other appliances on 
the circuit and protected by a 
circuit breaker as specified in 
Owner’s Manual.

Fan

EMI/RFI Filter

6020 0609

Risk of electric shock. 
Can shock, burn or kill. 
Risk issues to be aware of:  
•  Drive’s internal 

components retain 
high voltage for up to 
5 minutes after input 
power is disconnected.

•  EMI/RFI Filter carries 

high voltage when 
pump is running.

1

5997 0412

Typical 230VAC 

Circuit Breaker 

(Double Width)

         Indoor Installation Procedure

•  Begin procedure by removing screw at bottom of front cover.
•  Pull top of cover towards you, away from back plate to create gap.
•  Pull bottom of cover towards you; liftup on cover and remove.
•  Mount the Drive vertically on post, stud, or flat surface.
•  Permanently attach the Drive using top slotted hole, plus either the 

three bottom holes (for flat surface mounting) or the center bottom 
hole (for attaching to post or stud).

•  Leave 3” clearance around the Drive for proper cooling.
NOTICE After all wiring connections in Step 2 are complete, reattach 
cover by hooking it on top of back plate (be sure to leave gap). Lower 
bottom of cover into place. Push cover evenly against back plate, 
eliminating gap. Replace screw at bottom of front cover.

Press Enter

Press Enter

Press Enter

Press Enter

6566 0512

Apply 230V to Drive

Set Time

Set Date

Setup Complete

1 Phase

Connection Type

(2 Wire or 3 Wire)

3 Phase

Motor Type

Subm or Above Gnd

Enter Service

Factor Amps

Enter Motor Phase

(1 Phase or 3 Phase)

Press Enter

Initial Startup: 

Program the Drive

Apply 230V power to the 
PENTEK INTELLIDRIVE. 
“Setup Guide” will appear 
in the display. Follow 
the keypress sequence 
shown here:

3

Setup  Guide       12:10p

Service Factor Amps
Stopped     

6000 0509

Select 80 Hz Operation, if Necessary:

A. Press MAIN MENU button.
B.  Follow the keypress sequence shown here:

6570 0512_EN

Use arrows to 

scroll to Motor

Press Enter

Use arrows to 

select 80 Hz

Press Enter 

to save

Press MAIN MENU 

button

Press Enter

Use arrows to select 

Max Frequency

Initial Startup: Check List

•  Ensure system has properly sized relief valve and pressure tank.
•  Ensure that pressure tank’s precharge is 70 percent of the drive set pressure 

(42 PSI for the default set-point of 60 PSI).

•  Make sure that the pump discharge is connected to the system.
•  Ensure input ground, output ground, and transducer shield wire are properly 

connected.

5

Press Enter

Press Enter

Press Enter

Press Enter

6566 0512

Apply 230V to Drive

Set Time

Set Date

Setup Complete

1 Phase

Connection Type

(2 Wire or 3 Wire)

3 Phase

Motor Type

Subm or Above Gnd

Enter Service

Factor Amps

Enter Motor Phase

(1 Phase or 3 Phase)

Press Enter

NOTICE Motor 
must have twice 
the HP of pump for 
80Hz operation. 
See Owner’s 
Manual for more 
information.

(Continued next column)

NOTICE Nameplate amps may differ from these 
values. For PENTEK motors, use the values 
given here.
In submersible retrofit applications with other 
manufacturer’s 3-wire, 1-Phase motors, use the 
Cap Start/Cap Run values supplied by the motor 
manufacturer. For 3-Phase motors use the motor 
manufacturer’s service factor amps.
For above ground motors use the highest amp value 
given (may be listed as “max load amps” or “full 
load amps.”)
NOTICE See Owner’s Manual for more illustrations 
and detailed information.

For support call:

PENTEK Customer Service

866-9PENTEK (973-6835)

Quick Start Guide

Refer to the Owner’s Manual for installation, operation, and safety information.

This guide neither supplements nor replaces the Owner’s Manual.