background image

 

©  PCE Instruments 

 

 
 
 
 
 

 

 

PCE-POE 10 Cable Tester 

User Manual 

User manuals in various languages (français, 

italiano, español, português, nederlands, türk, polski, 

русский, 

中文

) can be found by using our 

product search on: www.pce-instruments.com 

Last change: 3 February 2021 

v1.0 

E

nglis

h

 

Summary of Contents for PCE-POE 10

Page 1: ...Cable Tester User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 3...

Page 2: ...ations 2 2 1 Delivery scope 2 3 Device description 3 3 1 Main menu 4 3 2 PoE switch test 4 3 3 PoE power test 6 3 4 Cable test functions 6 3 5 Power test function 8 3 6 Loop back test 8 3 7 Lighting f...

Page 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Page 4: ...ement range 0 18 W Measurement functions Voltage measurement range DC 0 60 V Current measurement range 0 3 A Power measurement range 0 180 W Max input power DC 48 V 5 mA Max Input current 80 mA Loop b...

Page 5: ...ight 6 On off switch 11 Arrow key right 2 PoE test connection 7 DC Out 12 OK 3 RJ 45 loop back connector 8 DC In 13 RJ45 connection for cable test functions 4 RJ 45 connector for cable test functions...

Page 6: ...omatic power off display contrast and display of the software version 3 2 PoE switch test Connect a network cable between the PoE switch and the PCE POE 10 RJ45 connection 2 see above The correct conn...

Page 7: ...ows 3 2 3 Connect Error If the error message Connect Error appears it is possible that additional POE end devices are connected to the POE switch to be tested Disconnect the cable connection of these...

Page 8: ...d PSE does not comply with the current standards if no message appears on the display the connected PSE complies with the current standards 3 4 Cable test functions This function can be used to find s...

Page 9: ...connected network cable the following appears on the display of the PCE POE 10 example cores 1 8 and 5 6 are crossed 3 4 4 Cable open If the message Cable open appears on the display of the PCE POE 1...

Page 10: ...E or PD itself to the DC OUT output 3 6 Loop back test The loop back test can be used to test individual ports on a switch or end device The PCE POE 10 sends data packets and attempts to receive them...

Page 11: ...et between 15 s 30 s 60 s On and Off 3 8 3 Automatic power off The automatic power off of the meter can be set at intervals of 15 30 and 60 minutes or disabled by selecting off 3 8 4 Display contrast...

Page 12: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Page 13: ...tanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 0583 975 114 Tel 0212 471 11 47 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 Faks 0212 705 53 93 info pce instruments co uk...

Reviews: