PCE-GM 75 Gloss Meter 

User Manual 

User manuals in various languages (français, 

italiano, español, português, nederlands, türk, polski, 

русский, 

中文

) can be found by using our 

product search on: www.pce-instruments.com 

Last change: 2 December 2019 

v1.0 

E

nglis

h

 

Summary of Contents for PCE-GM 75

Page 1: ...s Meter User Manual User manuals in various languages français italiano español português nederlands türk polski русский 中文 can be found by using our product search on www pce instruments com Last change 2 December 2019 v1 0 English ...

Page 2: ... Applications 2 3 Instrument Characteristics 2 4 Specifications 2 5 Display descriptions 2 6 Operation instructions 3 7 Menu instructions 3 8 Modifying the calibration value 3 9 Setting the time 4 10 Important notice 4 11 Warranty 4 12 Disposal 4 ...

Page 3: ...ns The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only be cleaned with a damp cloth Use only pH neutral cleaner no abrasives or solvents The device must only be used with accessories from PCE Instruments or equivalent Before each use inspect the case fo...

Page 4: ...p High measurement precision Backlit LCD digital display with accurate battery life and time display Auditory feedback during operation Automatic shutdown USB interface for PC connection Stores up to 1245 measurements 4 Specifications Measuring range 0 99 9 GU 100 1000 GU Resolution 0 1 GU 1 GU Repeatability 0 45 GU 0 5 Accuracy 1 GU 1 Measurement geometry 60 Measuring surface Ø4 5 mm Data storage...

Page 5: ...d 7 Menu instructions When the device is ready for use press and hold the button until the display changes and SET MENU is highlighted Release the button to enter the next screen The display change looks as follows The cursor now cycles top to bottom the options of the next menu Press the button when the desired option is highlighted in order to select 8 Modifying the calibration value If you wish...

Page 6: ...ld batteries with new ones Please note the polarity of the contact wires The batteries should be replaced when depleted otherwise long term storage may cause liquid to leak out and damage the device If the device will not be used for a longer period of time the batteries should be taken out and kept in a safe place 11 Warranty You can read our warranty terms in our General Business Terms which you...

Page 7: ...3 975 114 Fax 49 0 2903 976 99 9971 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce instruments com info pce instruments co uk info pce italia it www pce instruments com deutsch www pce instruments com english www pce instruments com italiano The Netherlands China Hong Kong PCE Brookhuis B V PCE Beijing Technology Co Limited PCE Instruments HK Ltd Institutenweg 15 1519 Room 6 Building Unit J 21...