background image

Installation

and Operating

Instructions

As part of Parmco Appliances commitment to improving and updating product ranges,

we reserve the right to alter, change and update technical specifications and appearance

attributes of all Parmco Appliances products. E&OE.

Models: 

 

In-bench 600mm

 

In-wall 600mm 

 

In-wall 900mm 

 

Side Riser 600mm

 

Rear Riser 600mm

 

Rear Riser 900mm

Summary of Contents for In-bench 600mm

Page 1: ...to improving and updating product ranges we reserve the right to alter change and update technical specifications and appearance attributes of all Parmco Appliances products E OE Models In bench 600mm...

Page 2: ...te of all detailed technical information and installation instructions It is essential that you only allow a qualified technician to install this appliance to ensure the safety and reliability of this...

Page 3: ...4 Ducting Requirements 5 Motor Mounting 6 Installation 6 In bench without controls 6 In bench with controls 7 Side Riser 7 Rear Riser 8 In wall 600mm and 900mm 13 Changing from P1 to P1 9 1 motor 15 E...

Page 4: ...with the appliance This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been...

Page 5: ...in bench Downdraft is placed next to a gas hob the unit must never be operated unless the flame deflector is in place The flame deflector is available in single and double sided options Please refer t...

Page 6: ...tchen exhaust gas and fumes Parmco Appliances have a comprehensive range of ducting components available For optimum efficiency ensure the use of short smooth exhaust pipe as few pipe bends as possibl...

Page 7: ...s concerned have to be observed for discharging air through smoke or exhaust flues not in use When the Downdraft is operated at the same time as chimney dependent fire installations are used eg gas oi...

Page 8: ...ated Specific Electrical Requirements The Downdraft unit can be operated through a simple on off switch in the wall above the unit and a 3 pin socket under the bench to get power supply to the motor O...

Page 9: ...e rear of the Carrier Place the top Surround on top of the Airbox and secure to the Airbox by means of two screws provided Mount the Motor on the airbox and do up the 4 nuts working down through the t...

Page 10: ...ws Adjacent to a 600mm Parmco gas electric hob excluding ceramic When being placed next to gas hobs a 75mm wide space between the hob and the downdraft unit is sufficient space for a wok or large fryi...

Page 11: ...x 122mm Determine which side the motor should be fastened to the airbox Note that this will influence ducting requirements Pipes nogs or other material in any walls or floor may have to be cut to acc...

Page 12: ...cut out depth Cut Out Dimensions to allow for the Rear Riser 600mm Rear Riser Depth 85mm Width 550mm 900mm Rear Riser Depth 85mm Width 830mm RISER HOB REAR RISER IS SUSPENDED INTO THE CAVITY SITS FIR...

Page 13: ...be a gap of approx 5mm between the edge of the cooktop and the Downdraft unit Secure the front of the cooktop to the bench using the clamps supplied Place the 16mm x 20mm piece of MDF along the unders...

Page 14: ...Mounting Position the motors in their correct orientation on the desired side of the airbox and rotate them so that they are on either side of the airbox with the exhaust facing downwards OR The exha...

Page 15: ...an island cooktop situation Airbox Motor Mounting Position the motors in their correct orientation on the desired side of the airbox and rotate them so that they are on either side of the airbox with...

Page 16: ...d The airbox should be centred behind the cooktop and installed between wall studs and secured to a horizontal noggin or dwang The optimum fitted height of the airbox is 250 300mm above the benchtop t...

Page 17: ...ked out 60mm to allow flush fitting before the wall lining is fitted Alternatively the nogs can be removed and the airbox can be framed as for a window and ducting can be mounted between jack studs Du...

Page 18: ...NING THIS APPLIANCE MUST BE EARTHED The wires in the mains lead are coloured in accordance with the following code Green Yellow Earth Blue Neutral Brown Live For plug in connection An electrical plug...

Page 19: ...age 220 to 240 volts AC at 50 Hz This appliance satisfies the EC regulations for radio screening P1 9 MOTOR Length of connecting cable 1 5m Power consumption 400 watts for the HT motor used in the 900...

Page 20: ...wndraft off at the wall switch riser will remain in an upright position Remove the top cap Carefully remove the aluminium mesh filter Removal from the benchtop Disconnect the electrical connection If...

Page 21: ...600mm Mega P2WALL MEGA P1 9 MOTOR In Wall 900mm P2W 9 P1 9 MOTOR Outlet designed for Supertube Outlet designed for Megaduct The 900mm Inwall Downdraft airbox must be framed as for a window Outlet desi...

Page 22: ...20 Standard Mounting In Bench Remote Mounting In Bench P1 Motor Up to 750m hr P1 9 Motor Up to 1000m hr...

Page 23: ...21 Remote Mounting In Wall Airbox...

Page 24: ...22 600 In wall Mega...

Page 25: ...bove are intended as a range of possibilities that the modular compenents of the Parmco Downdraft can offer There are often many possible solutions to an insatallation situation contact Parmco custome...

Page 26: ...can be for the product itself or if installed with a kitchen or house then proof of purchase can be from a Parmco reseller of products supplied by Parmco Liability under this warranty will not be acc...

Reviews: