background image

COMSPHERE

 3800Plus

SERIES MODEMS

MODELS 3810Plus and 3811Plus

QUICK REFERENCE

Document No. 3980-A2-GL10-10

Summary of Contents for COMSPHERE 3810Plus

Page 1: ...COMSPHERE 3800Plus SERIES MODEMS MODELS 3810Plus and 3811Plus QUICK REFERENCE Document No 3980 A2 GL10 10 ...

Page 2: ...e to this manual Warranty Sales and Service Information Contact your local sales representative service representative or distributor directly for any help needed For additional information concerning warranty sales service repair installation documentation training distributor locations or Paradyne worldwide office locations use one of the following methods H Via the Internet Visit the Paradyne W...

Page 3: ...ument 3980 A2 GB30 COMSPHERE 3800Plus Series Modems User s Guide To request a paper copy of a Paradyne document H Within the U S A call 1 800 PARADYNE 1 800 727 2396 H Outside the U S A call 1 727 530 8623 Before installing your modem read the Important Safety Instructions on page 23 Package Checklist After opening the modem s package check for damage and verify that the following items are presen...

Page 4: ...he modem s rear panel Use a small screwdriver to fasten the cable to the modem 3 Connect the DB 25 P connector on the cable to the DB 25 S connector on the DTE Use a small screwdriver to fasten the cable to the DTE 98 14677 03 DATA TERMINAL EQUIPMENT DB 25 P CONNECTOR SUB MINIATURE 4 POSITION PLUG FOR NETWORK MANAGEMENT SYSTEM OPERATION POWER SUPPLY DIAL NETWORK 6 POSITION PLUG LEASED LINE NETWORK...

Page 5: ...of the modular cord into the leased line network interface 3 If you intend to use dial backup follow steps listed in Dial Line Connection section AC Power Supply Connection WARNING Power supplies from other modems may fit into the POWER connector but connecting the wrong power supply can cause damage to the modem or the power supply Use the following procedure to connect the modem to an ac power o...

Page 6: ...MS 2 Connect the 3600 Hubbing Device to the network management system Refer to the 3600 Hubbing Device Feature Number 3600 F3 300 Installation Instructions for more information Installation for the 3810Plus modem is the same as for the 3610 DSU 3000HUBBING DEVICE MODEL 3000 F3 300 8 Pin Modular Jacks 6 Inches Overall 4 Pin Modular Plug 496 13775 03 8 1 Pin Numbers 8 1 C C I N D C O U T C C O U T D...

Page 7: ...ingle SDCP can control modems in up to eight carriers To install a 3811Plus modem into the carrier perform the following steps 1 At the rear of the carrier install the rear connector plate Make sure the plate uses the same slot position as that intended for the modem 496 14906 V 35 3600 3500 RS366A V 25 3800 EIA232 V 24 25 Pin DTE Connectors P21 Loosely fasten the plate This allows for slight adju...

Page 8: ...des of one of the slots numbered 1 16 Slide the modem into the slot aligning the modem with the rear connector plate until the backplane connector and DTE connector seat firmly into the back of the carrier To lock the modem into the carrier press the faceplate latch until a click is heard 3 Rotate the circuit pack lock s into the closed position and tighten the screw ...

Page 9: ... LEDs light up If the modem fails or an alarm condition exists the Alrm LED on the faceplate lights up or flashes It may be possible to run a diagnostic self test from the SDCP See Test Branch in the COMSPHERE 3800Plus Modems User s Guide Return to the rear of the carrier and tighten the rear connector plate 5 Connect an RS 232D DTE cable to the top connector of the rear connector plate The bottom...

Page 10: ...t Panel 3811Plus 142 125 Spkr Moves up one level from the current display Moves cursor or display to the left or right Returns display to Top Level menu Selects item displayed directly above the key F1 F2 F3 and Direction and Function keys provide operator control Hidden Choice Indicators Indicates more LCD selections are available to the left or right of what is currently displayed on the LCD Ind...

Page 11: ...key to position the cursor on the slot selection entry 5 Press the F1 or F2 key until the slot number 1 16 you want appears on the LCD Ignore the AB designator that appears on the LCD since it is not applicable to the 3811Plus modem The Front Panel LED on the modem s faceplate lights up 6 Press the Select key to place the SDCP in direct communication with the selected modem The LCD displays the To...

Page 12: ...ng Dialer Type DialTone Detect Blind Dial Paus BusyTone Detect Pause Time NoAnswer Timout Fast Disconnect Long Space Disc No Carrier Disc No Data Disc NoDataDiscTrig Auto Make Busy MakeBusyViaDTR DTR Auto Redial MI MIC Dialing Dial_Line Modulation Dial Line Rate Automode Autorate Dial TX Level V22b Guard Tone Train Time Asymmetric Rate Proactive Retrain Fall Fwd Delay 98 15990a 01 Displays current...

Page 13: ...DTR Alarm NetworkPosition CellulrRJ11Adpt Security EntryWait_Time VF_Prompt_Type DTE_PW_Tries DTE_PW_TermChar DTE_PW_BkSpChar Get_User_ID NMS_Reporting Answer_Secur Originate_Secur 98 15990b Does not appear if configured for Synchronous mode Only appears if Sync_Leased factory template is selected Some choices within this group may not appear depending upon how previous configuration options have ...

Page 14: ...ervLine Download Code Secondary Prim data blckd ExitRem appears instead of Remote when using Remote Mode Does not appear in Remote Mode Security Set_Access_Ctrl Admin Password Reset_Security EditPassWdTable Set_Answer_Sec Set_Orig_Secur Set_Admin_PsWd 98 15990c 01 from previous page ...

Page 15: ...vailable Select Configure from the Top Level menu F1 Idle 28 8 Test Configure F2 F3 Scroll to the area you wish to load F1 Ld EditArea frm Factory F2 F3 2 Select Edit to choose the set of configuration options to be edited DTE Interface DTE Dialer Line Dialer Dial Line Leased Line V 42 MNP Buffer Tests Misc or Security F1 Edit StrapGroup Test Misc F2 F3 3 When the new configuration is completed Sa...

Page 16: ... Sync Leased Answer 3 UNIX Dial 4 Sync Leased Originate 5 Cellular Mobile if ETC installed 6 Cellular PSTN if ETC installed where n is one of the following configuration areas 0 Active Saved 1 Customer 1 2 Customer 2 Loading Configuration Areas to Active Operating Use the ATZn command to load stored configurations from Active Saved Customer 1 or Customer 2 configuration areas to Active Operating T...

Page 17: ... Speaker ON until carrier signal becomes active M2 Speaker always ON O Returns modem to Data mode from online Command mode P Enables Pulse Dial mode Qn Result Codes Q0 Enables result codes Refer to Result Codes section Q1 Disables result codes Q2 Enables originate modem to send result codes to the DTE Required for most UNIX applications Sn Displays value of S Register where n is the register numbe...

Page 18: ...nnect until DTR lowered by DTE AT COMMANDS continued Fn Loads Factory Configuration F0 Loads Async Dial factory configuration options into Active Operating configuration area F1 Loads Sync Dial factory configuration options into Active Operating configuration area F2 Loads Sync Leased Answer Mode factory configuration options into Active Operating configuration area F3 Loads UNIX Dial factory conf...

Page 19: ...ote Digital Loopback test V 54 type L2 T7 Starts a Remote Digital Loopback test with a Pattern V 54 type L2 T8 Starts a Local Analog Loopback test with a Pattern V 54 type L3 T9 Starts a self test AT COMMANDS continued Vn View Configuration Options V0 Displays Active Operating configuration options V1 Displays Active Saved configuration options V2 Displays Customer 1 configuration options V3 Displ...

Page 20: ...es flow control of DTE Q1 Q4 Enables XON XOFF flow control Q2 Q3 Modem raises and lowers CTS to start and stop flow control Qn Flow Control of Modem Q0 Q2 Q4 Disables flow control of modem Q1 Q5 Enables XON XOFF flow control Q3 Q6 Modem starts and stops flow control based upon state of DTE s RTS signal AT COMMANDS continued Tn No Data Disconnect Timer T0 Disables no data disconnect timer Tn Sets n...

Page 21: ...21 11 CONNECT 4800 EC 22 12 CONNECT 9600 EC 23 16 CONNECT 12000 EC 24 13 CONNECT 14400 EC 25 17 CONNECT 16800 EC 26 15 CONNECT 7200 EC 27 5 CONNECT 1200 EC 29 14 CONNECT 19200 EC 37 37 CONNECT 21600 38 38 CONNECT 24000 39 39 CONNECT 26400 40 40 CONNECT 28800 41 41 CONNECT 31200 42 42 CONNECT 33600 43 43 CONNECT 21600 EC 44 44 CONNECT 24000 EC 45 45 CONNECT 26400 EC 46 46 CONNECT 28800 EC 47 47 CON...

Page 22: ... LAPM_Discon S29 SDC Idle Fill 0 0 Flag_Fill 1 Mark_Fill S30 Sync DTE Rate 0 0 12800 bps 1 115200 3 96000 4 78800 5 72000 6 64000 7 57600 8 56000 9 48000 10 38400 11 28800 12 19200 13 14400 14 9600 15 4800 16 2400 17 1200 S31 SDC Bit Encoding 0 0 NRZ 1 NRZI S32 Sync DTE CRC 0 0 Ignore 1 CRC16 S33 Buffer Size In Buffer Mode 0 0 Normal 1 Minimized S35 Auto Redial 0 0 Dir1 1 Dirs1 2 2 Dirs1 3 9 Dirs1...

Page 23: ... 1 Enable S52 DTE LL CT141 0 0 Disable 1 Enable S53 V 54 Address 0 0 Disable or 1 34 S54 V 54 Device Type 0 0 Peripheral 1 Intermediate S55 Access from Remote 0 0 Enable 1 Disable S56 Remote Access Password 00 00 99 1st and 2nd digits S57 Remote Access Password 00 00 99 3rd and 4th digits S58 Remote Access Password 00 00 99 5th and 6th digits S59 Remote Access Password 00 00 99 7th and 8th digits ...

Page 24: ...ling 0 0 Disable 1 Enable S84 AT Command Mode 0 0 Normal 1 No Error 2 No Strap or ERROR S85 Fast Disconnect 0 0 Disable 1 Enable S88 Straps When Disconnected 0 0 No Change 1 Reload 2 Reload No Change S89 V 42 ARQ Window Size Increase 0 0 6 frames 9 15 frames S90 DTE Rate VF Rate 0 0 Disable 1 Enable S91 Cellular Enhancement if ETC installed 0 0 Disable 1 Enable S92 V 29 Train On Data if V 29 insta...

Page 25: ...can create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnected the voltage potential may cause a hazardous condition Consult a qualified electrical consultant to determine whether or not this phenomenon exists and if necessary implement corrective action prior to interconnecting the products 8 Input power to this pro...

Page 26: ...ERENCEĆCAUSING EQUIPMENT REGULATIONS CET APPAREIL NUMÉRIQUE DE LA CLASSE A RESPECTE TOUTES LES EXIGENCES DU RÈGLEMENT SUR LE MATÉRIEL BROUILLEUR DU CANADA Government Requirements Certain governments require that instructions pertaining to connection to the telephone network be included in the installation and operation manual Specific instructions are listed in the following sections Note that 381...

Page 27: ...t needs to be returned to the company service center for repair contact them directly for return instructions using one of the following methods Via the Internet Visit the Paradyne World Wide Web site at http www paradyne com Via Telephone Call our automated call system to receive current information via fax or to speak with a company representative Within the U S A call 1 800 870 2221 Outside the...

Page 28: ...situations Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of ...

Reviews: