1. Introduction

The LPB-6-60-NJ antenna covers 2G/3G/4G and 5G frequencies (617-960/1710-6000MHz). The antenna is supplied with a wall / mast mount bracket as 

standard but can also be mounted on metal panels or enclosures of sufficient size. The antenna is supplied with a N bulkhead (f) type connector.

4. Routing and Terminating Coaxial Cable(s)

Connect the coaxial cable fitted with N Plug connector and tighten to 1Nm (0.75 ft Lbs). Route the coaxial cables to the radio equipment, taking care to avoid 

running them adjacent to any existing wiring or fouling any moving components. 

2. Mounting Requirements and Selecting Location

Bracket Mounting:

 Select a suitable mounting location for the antenna on the desired surface. The orientation of the antenna should be vertical with the 

connector facing downwards. When selecting a mounting location care should be taken to ensure that at least 300mm (12”) of separation is maintained 

between the antenna and nearby metal objects and surfaces. When mounting the antenna to a metal housing, device enclosure or mast care should be 

taken to ensure that the antenna housing is elevated above the metal surface to which it is mounted. Ensure that the selected location will enable the 

coaxial cable to be easily connected and routed to the equipment. If mounting the antenna using screws it is important to check for adequate under panel 

clearance.It is important for RF performance that the antenna is only bracket mounted using the supplied bracket. Mounting the antenna utilising a different 

bracket may adversely affect performance. 

Panel Mounting: 

The antenna must be fitted to a conductive ground plane of adequate size. It will fit panels of between 1-15mm thick (0.04-0.6”) The 

recommended minimum diameter of the surface is 200mm (8”). Select a mounting location taking care to ensure that there is at least 300mm (12”) of 

clearance from proximate metal objects. Ensure that there is adequate clearance under the mounting panel and measure to check for central positioning if 
necessary.

3. Antenna Mounting

Bracket Mounting:

 Check that you have the required mounting hardware and equipment available. The antenna can be bracket mounted via the supplied 

fixing holes (suitable for machine screws or self-tapping screws) or mast mounted using a suitable jubilee or worm drive hose clip. If drilling holes to mount 

the antenna the bracket can be used as a drilling template. When ready mount the antenna securely to the bracket using the supplied nut and washer. It 

is not necessary to remove the backing from the supplied adhesive pad but the pad can be utilised if a more permanent fitment to the bracket is desired. If 

utilising the adhesive pad, ensure that the top surface of the bracket is clean and dry, remove the backing from the adhesive pad and stick the antenna to 

the bracket applying firm pressure.

Panel Mounting: 

Mask the panel area around the hole position to protect the surface / paintwork. Drill a pilot hole, then increase the hole size to 16mm 

(0.63”), ensuring that the drill / cutter bit does not hit any objects under the panel. Clean the area around the hole carefully removing all swarf. Remove any 

paint and primer from underneath the panel surface to ensure adequate electrical contact using washer and nut.Remove the nut and washer and then the 

adhesive pad  backing from the underside of the antenna and feed the coaxial cable through the panel. Position the antenna over the mounting hole and 

stick it to the panel applying firm pressure. Assemble the nut and washer from under the panel and tighten fully. 

Recommended tightening torque for the mounting nut in both installation scenarios is 5Nm (3.6 ft lbs).

Note: Where the adhesive pad is required for sealing the installation it is recommended that the installation is not carried out  if the temperature is less than 

50°F (10°C) as the ideal temperature for the pad bonding is 70°F (21°C) to 100°F (37°C).