WJ-FS309
WJ-FS316
WJ-FS409
WJ-FS416

Video Multiplexer

Operating Instructions

ENGLISH

FRANÇAIS

Summary of Contents for WJFS316 - DIGITAL MULTIPLEXER

Page 1: ...deo Multiplexer WJ FS 409 FS Before attempting to connect or operate this product please read these instructions carefully and save this manual for future use Model No WJ FS309 WJ FS316 WJ FS409 WJ FS416 Video Multiplexer Operating Instructions ENGLISH FRANÇAIS ...

Page 2: ...EFER SERVICING TO QUALIFIED SERVICE PERSONNEL CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN SA 1965 SA 1966 NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equip...

Page 3: ...Video Multiplexer 25 Connection with the Monitors 26 Connection with the WV CU360 System Controller 26 ALARM REMOTE Connector 27 Connection with the Alarm Sensors 28 Connection with the Alarm Output 28 Connection with the Remote External Switches 29 OPERATING PROCEDURES 30 Monitoring the Camera Picture 30 Recording on the Time Lapse VCR 34 Monitoring the Playback Picture 34 ALARM CONTROL FUNCTION ...

Page 4: ...th Panasonic Security Data mode the bear logo The WJ FS309 FS316 FS409 FS416 can be controlled from a PC or the System Control Unit example WV CU360 via an RS 485 interface The pictures of any connected camera can be dis played as a Spot picture on a full screen or Sequential screen or as shown below on a 4 9 or 16 segment Multiscreen Still and zoom modes full screen only are available both for li...

Page 5: ...e the appli ance Do not expose the appliance to water or moisture nor try to operate it in wet areas Do take immediate action if the appliance becomes wet Turn the power off and refer servicing to qualified service personnel Moisture can damage the appliance and also cause electric shock Do not use strong or abrasive detergents when cleaning the appliance body Use a dry cloth to clean the applianc...

Page 6: ... This button resets the active Alarm mode Pressing this button turns off the Alarm indicator and replaces the Alarm indication on the monitor screen with the cam era title SWITCH PROTECTOR WJ FS316 FS416 e Alarm Indicator ALARM This indicator blinks when an alarm is activated It changes to steady light when the auto reset time has elapsed or the alarm recovery signal is received from the VCR To tu...

Page 7: ...tor instead of through the Video Multiplexer As a result the playback picture will not be recognizable unless only a single channel is recorded throughout the tape The 4A screen is a compressed picture of channels 1 through 4 the 4B of channels 5 through 8 the 4C of channels 9 through 12 and the 4D of channels 13 through 16 The 9 segment screen shows the pictures of channels 1 through 9 in a 3x3 p...

Page 8: ...LAY IN The playback signal from the time lapse VCR is sup plied to this connector t Record Output Connector REC OUT The recording signal for the time lapse VCR is provided via this connector y Multiscreen Output Connector MULTISCREEN OUT The video output signal for the multiscreen monitor is provided via this connector u Spot Output Connector SPOT OUT Provides the video output signal for the spot ...

Page 9: ...or to the left B Moves the cursor to the right Selects the mode or parameter Selects the mode or parameter SET Executes the selections and displays a submenu for an item with the mark Press the MENU ESC button to execute the currently highlighted setting and return to the previous menu in the SETUP MENU To finalize the setting and return to normal viewing press the MENU ESC button for 2 seconds wh...

Page 10: ...AMS Camera Channel ENCODE MONITOR OUTPUT SETUP Monitor Output Setup REC OUTPUT SETUP Record Output Setup SEQUENCE SETUP Sequence Setup SYSTEM SETUP System Setup Page 13 Page 17 MULTI OUTPUT AUTO SKIP Automatic Skip SEQ MODE AUTO SKIP Automatic Skip SPOT OUTPUT MLT SPT SEQ SETUP Page 15 DYNAMIC REC Dynamic Recording ALM REC MODE Alarm Recording Mode AUTO RESET Automatic Reset ALM DISPLAY Alarm Disp...

Page 11: ...ls to exclu sive recording of a specified channel 1 Move the cursor to the DYNAMIC REC parameter 2 Select OFF ALM PRI ALM ONLY or GROUP by pressing the or button The initial factory setting is OFF OFF The video signals are recorded from channels number 1 to 9 WJ FS309 FS409 or 1 to 16 WJ FS 316 FS416 regardless of any channels receiving the alarm signal ALM PRI The video signal of the channel that...

Page 12: ... 5M The connected external device is driven for the duration set here S and M stand for seconds and minutes EXT The Alarm Output signal continues until the ALARM RESET button is pressed or an alarm recovery signal is supplied from the VCR 6 ALM BUZZER This item lets you select the ringing duration of the built in alarm buzzer when alarm is activated 1 Move the cursor to the ALM BUZZER parameter 2 ...

Page 13: ...set button do not valid on condition that alarm reset does not complete SPOT The camera picture whose alarm is activated is displayed and retained until the alarm is reset Monitor Output Setup Menu 1 MULTI OUTPUT Move the cursor to MONITOR OUTPUT SETUP on the SETUP menu then press the SET button The MONI TOR OUTPUT SETUP menu appears on the monitor screen as shown below WJ FS316 SETUP ALARM SETUP ...

Page 14: ...when the MULTISCREEN SELECT button is pressed on the front panel Quad shift displays a picture series such as 1 2 3 4 5 6 7 8 9 10 11 12 or 13 14 15 16 on quad screens WJ FS309 FS409 is only available 1 2 3 4 or 5 6 7 8 1 Move the cursor to the QUAD SHIFT parameter 2 Select ON or OFF by pressing the or button The initial factory setting is OFF ON Enables the quad shift operation OFF Disables the q...

Page 15: ...ontrolled by the camera switching signal supplied by the con nected VCR Note If set to EXT make sure that the CAMERA SW IN terminal on the rear panel is connected to the Time Lapse VCR 1 1 AUTO SKIP This item lets you enable or disable the Auto Skip function to skip any steps where no video signal is present at the multiscreen output 1 Move the cursor to the AUTO SKIP parameter 2 Select either ON ...

Page 16: ...screen except the bottom right display pictures in the selected sequence and dwell time Dwell time Can be set to 2S 30S Example Notes The display position of 9 segment screen pictures in Sequence mode is fixed for channels 1 to 8 It cannot be changed This function is available only for the WJ FS316 FS416 Video Multiplexer 1 3 4 2 SEQ Channels 4 16 flash at 2 second intervals dwell time 2S 1 3 4 5 ...

Page 17: ... SETUP TITLE POSI CAM SW LOSS ON PLAYBACK AUTO ON PASSWORD OFF PWR ON MULTI QUAD 4A PWR ON SPOT 1 COM SETUP SYSTEM SETUP 2 2 ENCODE PANA SYSTEM SETUP 2 2 ENCODE OTHERS SW INTERVAL 1 NO OF CAMS 16 To go to SYSTEM SETUP 2 2 press the C button To go back to SYSTEM SETUP 1 2 press the D button 1 TITLE SETUP This item lets you edit the camera title to be displayed on the monitor screen Up to 8 alphanum...

Page 18: ...ther to display SW LOSS warning on the monitor when the camera switching pulse is not supplied from the VCR Notes This selection is effective only when the Recording Mode in the Record Output Setup Menu is set to EXT To reset the warning reconnect the CAMERA SW IN connector 1 Move the cursor to the CAM SW LOSS parameter 2 Select ON or OFF by pressing the or button The initial factory setting is ON...

Page 19: ...password The password currently registered can be changed as fol lows 1 Press the MENU ESC button for 2 seconds or more to display the password inquiry screen Then type in the current password by pressing the CAMERA SELECT buttons and the A or B button The SETUP menu appears 2 In the SYSTEM SETUP menu select ON for the PASS WORD parameter 3 Move the cursor to the first desired digit by pressing th...

Page 20: ...plexer 3 Repeat step 2 until each camera has been assigned a unique number 8 3 BAUD RATE Move the cursor to BAUD RATE and then select a rate by pressing the or button The initial factory setting is 9600 9600 4800 2400 Consult the RS 485 system configuration for the baud rate 8 4 DATA BIT Setting is fixed for 8 bit The cursor skips 8 5 PARITY CHECK Move the cursor to PARITY CHECK and then select a ...

Page 21: ...OTHERS is selected tapes recorded with a random order of camera channels e g recorded in ALM PRI ALM ONLY or GROUP mode will not be reproduced properly 1 Set ENCODE to OTHERS 2 For SW INTERVAL set the same value as for the VCR time mode 3 For NO OF CAMS set the number of cameras record ed on the tape Notes Set SW INTERVAL to 1 for tapes recorded in 24H mode or longer Set SW INTERVAL as follows for...

Page 22: ...er with the rack mounting brackets in the rack by using four screws not includ ed Cautions Do not block the ventilation opening or slots on the cover to prevent the appliance from overheating Always keep the temperature in the rack within 50 C 122 F Secure the rear of the appliance to the rack by using additional mounting brackets procured local ly if the rack is subject to vibrations Remove 4 rub...

Page 23: ...t pictures are displayed in black and white With certain monitor types color noise may appear in the picture In case of connecting multiple devices compatible with the Panasonic Security Data mode connect the unit in a daisy chain configuration The allowable connecting devices are up to 16 in a system The maximum allowable cable length of the system is approximately 500 m 1 650 ft SYSTEM CONNECTIO...

Page 24: ...OUT 11 REC REVIEW OUT 12 SERIES REC IN 13 14 TIME ADJUST IN 15 TIME ADJUST OUT 16 COM SERIES REC OUT 1 3 5 7 9 11 13 15 Video Multiplexer WJ FS309 FS409 or WJ FS316 FS416 VIDEO IN VIDEO OUT S VIDEO AUDIO CAMERA SW OUT GND 1 3 4 ALARM RECOVER OUT ALARM RESET IN ALARM IN Time Lapse VCR Example AG 6730 Alarm Reset Output Alarm Recovery Input 9 8 6 Alarm Output SIGNAL GND ALARM REMOTE PLAY IN REC OUT ...

Page 25: ...LEFT JOG RIGHT ALARM SEARCH STEP REW FF STOP SETUP PLAY REC OUT PLAY OUT REC OUT AUTO OFF OUT DISK END OUT IN OUT IN RECALL EXT REC OUT RECOVER OUT RESET IN IN ALARM SERIES RECORD G AUTO OFF OUT DISK END OUT OUT IN RECALL OUT RECOVER OUT RESET IN IN Video Multiplexer WJ FS309 FS409 or WJ FS316 FS416 Digital Disk Recorder Example WJ HD100 Alarm Reset Output Alarm Recovery Input 9 8 6 Alarm Output S...

Page 26: ...FS416 WV CU360 4 4 TX B WJ FS309 FS316 FS409 FS416 WV CU360 5 5 TX A WJ FS309 FS316 FS409 FS416 WV CU360 6 6 GND Controller end Setting the System Controller The setting is briefly described below For further details refer to the Operating Instructions for the WV CU360 System Controller 0 9 8 7 6 5 4 3 2 1 CONTROLLER No MODE 1 2 3 4 5 6 7 8 OFF ON 1 Rotate the CONTROLLER NO switch to set the con t...

Page 27: ...rm Remote 15 Alarm In 15 Remote In 15 SET 25 Alarm Remote 16 Alarm In 16 Remote In 16 ESC 9 Alarm Output Alarm Output Alarm Output Alarm Output 8 Alarm Recovery In Alarm Recovery In Alarm Recovery In Alarm Recovery In 6 Alarm Reset Out Alarm Reset Out Alarm Reset Out Alarm Reset Out 21 Sequence Sequence Sequence 7 GND GND GND GND 14 GND GND GND GND 20 GND GND GND GND For WJ FS309 FS409 Pin Pin Nam...

Page 28: ...2 Connection of devices exceeding drive capacity Connection with the Alarm Sensors Connect alarm sensors to the ALARM REMOTE connector As shown in the tables on page 27 the WJ FS309 FS409 accepts up to 9 sensors and the WJ FS316 FS416 up to 16 The sensors should meet the following specifications 1 Allowable input voltage Non voltage contact or 0 V to 5 V DC 2 Input definition Specified by ALM INPU...

Page 29: ...s The Video Multiplexer can be remote controlled if external switches locally procured are connected to the ALARM REMOTE connector Remote switches except SEQUENCE are grouped under Remote SW1 and SW2 For more information refer to the pin assignment tables on page 27 Notes Switch 10 through 16 are applicable only to WJ FS316 FS416 Make sure that the Function switch 1 is grounded and Function switch...

Page 30: ... SEQ button A sequence of single pictures is displayed in the order and dwell time selected for the MLT SPT SEQ SETUP parameter in the SEQUENCE SETUP menu Note Refer to the Sequence Setup on page 15 for more details 2 To cancel a sequence press the respective CAMERA SELECT button The selected camera picture appears in spot mode 2 Press a CAMERA SELECT button to display a camera picture on the moni...

Page 31: ...POT SEQ SETUP para meter in the SEQUENCE SETUP menu Note Refer to the Sequence Setup on page 15 for more details 2 To cancel a sequence press the respective CAMERA SELECT button or MULTISCREEN SELECT button The selected camera picture appears in spot mode 2 Confirm that the LED on the VCR CAM button is not lit If the LED is lit press the VCR CAM button so that the VCR CAM indicator goes off 3 Pres...

Page 32: ... pressed the picture is zoomed twofold The picture cannot be zoomed out to be smaller than the original size by pressing the button 5 To cancel this mode press the EL ZOOM button The selected picture is displayed in normal size in spot mode STILL STILL 3 Still Spot Picture The following function is available in MULTISCREEN OUT picture only 1 Repeat the procedures described above for Spot Picture 2...

Page 33: ...16 FS416 MULTI SCREEN SELECT WJ FS309 FS409 6 Still Multiscreen Picture 1 Repeat the procedures described above for Multi screen pictures 2 Press the STILL button so that the LED of STILL lights up VCR CAM 5 Multiscreen Picture 1 Press a SPOT MULTISCREEN button so that the LED of SPOT MULTISCREEN button goes off 2 Confirm that the LED on the VCR CAM button is not lit If the LED is lit press the VC...

Page 34: ...titles hard to read Select spot picture to make titles easier to read Playback in linear mode L12H L18H L24H may produce noise or the picture of another channel in any recorded mode Play back the tape in NORMAL real time mode or TIME LAPSE mode To play back pictures in the OTHERS mode of the ENCODE menu and display them as stills it is rec ommended to use the STILL button on the multi plexer not o...

Page 35: ...icture is dis played in normal size in spot mode STILL STILL Note The VCR continues playback while the still pic ture is displayed on the monitor screen 2 Still Spot Playback Picture 1 Repeat the procedures described above for Spot Playback Picture 2 Press the STILL button to freeze the displayed picture The LED on the STILL button lights up and the LED on the pressed CAMERA SELECT button starts t...

Page 36: ...gh 4 the 4B of chan nels 5 through 8 the 4C of channels 9 through 12 and the 4D of channels 13 through 16 MULTI SCREEN SELECT 1 3 2 4 4 SEGMENT SCREEN 1 2 5 6 3 4 7 8 9 10 13 14 11 16 SEGMENT SCREEN Only for WJ FS316 FS416 12 15 16 1 4 7 2 5 8 3 6 9 9 SEGMENT SCREEN WJ FS316 FS416 MULTI SCREEN SELECT WJ FS309 FS409 5 Still Multiscreen Playback Picture 1 Repeat the procedures described above for Mu...

Page 37: ... Alarm Buzzer The built in buzzer beeps for the programmed duration The buzzer stops beeping before that duration when the alarm is reset Record Output The pictures of channels where alarm is activated are recorded on the VCR in the mode specified for the ALM REC MODE parameter on the ALARM SETUP menu 1 Alarm Priority Mode The pictures of channels where alarm is activated are recorded with more fi...

Page 38: ...ALARM indicator changes from blinking to steady light 2 Alarm Channel Monitor Mode The picture of the channel where alarm is activated is dis played on the monitor if Alarm MLT OUT MODE is set to SPOT The picture displayed before alarm was activated will be restored after the alarm is reset It remains on the monitor if Alarm MLT OUT MODE is set to OFF Alarm Reset Manual Reset When an alarm is acti...

Page 39: ...he buzzer stops beeping MENU ESC 13 12 MENU ESC 5 4 ALL RESET Channel Loss Alarm Channel loss may occur initially after completing the setup with the WJ MP204 In this case press the ALARM RESET button Channel loss can be avoided by setting CHANNEL LOSS to OFF beforehand Operating the WJ FS309 FS409 from the WV CU360 System Controller When operating from the WJ FS309 FS409 the menu can be accessed ...

Page 40: ...Format Example These notice messages will not be implemented if the ALARM DATA is set to OFF in the SETUP menu of the Video Multiplexer Command Table 1 Video Multiplexer to System Controller Code STX ADuuu Command Parameter EXT ASCII 02H 03H 7 6 5 4 3 2 1 0 P P P P O O O O Checking Code Data that bit reversed notice of First Alarm Channel 3 digit number Bit Position Notice of First Alarm Channel 3...

Page 41: ...mode selection m 0 STILL OFF m 1 STILL ON Item Format Note Parameter Note Take a break for at least 270 ms equivalent to 16 V Sync from one transmission to the next especially when sending commands con secutively Send 1 5 channel Alarm mode sfx ADOOA ALM OF OF OF OF B7 OF efx Response None 5ch Alarm mode b1 b2 b3 a1 a2 a3 a4 0Fh 0Fh 0Fh 0Fh 87h 0Fh 0Fh 5ch 15ch 16ch Alarm mode b1 b2 b3 a1 a2 a3 a4...

Page 42: ...V p p 75 Ω composite video signal Spot Output 1 0 V p p 75 Ω composite video signal Data Input Output Based on RS 485 4 lines Modular Jack x 1 Alarm Remote Control 25 pin D sub Connector Alarm Recover Input 1 0 V 5 V DC Alarm Recover Output 1 0 V 5 V DC Alarm Output 1 No Voltage Contact O C 24 V DC less than 100 mA Ambient Operating Temperature 10 C 50 C 14 F 122 F Ambient Operating Humidity Less ...

Page 43: ...vision of Matsushita Electric Corporation of America Executive Office One Panasonic Way 3E 7 Secaucus New Jersey 07094 Regional Offices Northeast One Panasonic Way Secaucus NJ 07094 201 348 7303 Southern 1225 Northbrook Parkway Suite 1 160 Suwanee GA 30024 770 338 6838 Midwest 1707 North Randall Road Elgin IL 60123 847 468 5211 Western 6550 Katella Ave Cypress CA 90630 714 373 7840 2000 Matsushita...

Reviews: