background image

Hybrid IP-PBX

PT Programming Manual

Thank you for purchasing a Panasonic Hybrid IP-PBX.
Please read this manual carefully before using this product and save this manual for future use.

KX-TDA150: PDMPR Software File Version 5.1000 or later

Model No.     

KX-TDA150

Summary of Contents for KX-TDA150

Page 1: ...Manual Thank you for purchasing a Panasonic Hybrid IP PBX Please read this manual carefully before using this product and save this manual for future use KX TDA150 PDMPR Software File Version 5 1000...

Page 2: ...e Guide explains what the PBX can do as well as how to obtain the most of its many features and facilities Sections from the Feature Guide are listed throughout the PT Programming Manual for your refe...

Page 3: ...firm the software version of your PBX see 190 Main Processing MPR Software Version Reference Some optional hardware software and features are not available in some countries areas Please consult your...

Page 4: ...Idle Line Access Local Access 24 110 System Password for Administrator for PT Programming 24 111 System Password for User for PT Programming 24 112 Manager Password 24 120 Verification Code 24 121 Ve...

Page 5: ...l Detection Time Incoming 33 415 LCOT Reverse Circuit 33 416 LCOT Pause Time 33 417 LCOT Flash Recall Time 33 418 LCOT Disconnect Time 34 420 BRI Network Type 34 421 BRI DIL DDI MSN Selection 34 422 B...

Page 6: ...pacity 43 629 Queuing Hurry up Level 44 630 Queuing Time Table 44 631 Sequences in Queuing Time Table 44 632 Maximum Number of Agents 44 640 Extension User Groups of a Paging Group 44 641 External Pag...

Page 7: ...mote Programming 50 811 Modem Floating Extension Number 50 812 ISDN Remote Floating Extension Number 50 2 1 12 Card Programming 51 900 Slot Card Type Reference 51 901 Slot Card Deletion 51 902 Slot Ca...

Page 8: ...8 PT Programming Manual Table of Contents...

Page 9: ...Section 1 Overview This section provides an overview of programming the PBX PT Programming Manual 9...

Page 10: ...ng to enter system programming mode will be denied access Ways to Programme There are two programming methods PC Personal Computer Programming All features and settings of the PBX can be programmed th...

Page 11: ...ogramming All PT programming settings are available CAUTION To the Administrator or Installer regarding the system password 1 Please provide all system passwords to the customer 2 To avoid unauthorise...

Page 12: ...storing a name message or other text entry data using a PT The tables below show you the characters available by pushing each button a specific number of times Table 1 Standard mode Table 1 Standard m...

Page 13: ...Table 2 Option mode Table 2 Option mode for CE model PT Programming Manual 13 1 1 3 Entering Characters...

Page 14: ...ht press When entering two or more characters that use the same button consecutively e g G and I you must press this button or the FWD DND button after entering the first character If SELECT is presse...

Page 15: ...Section 2 PT Programming This section serves as reference operating instructions when using a display PT to programme the PBX PT Programming Manual 15...

Page 16: ...ered port on the card installed in the lowest numbered slot Only one system programming session can be performed at a time This means that only one user can access system programming at a time whether...

Page 17: ...PROGRAM PAUSE 1234 System Password for Administrator Programming No 3 digits for PT Programming User Level Allows the programming of limited settings as permitted through PC programming 1234 Programm...

Page 18: ...ture settings 7XX Resource Interface Programming PBX interface and external device settings 8XX SMDR Maintenance Programming Station Message Detail Recording SMDR and maintenance feature settings 9XX...

Page 19: ...the example below 410 DTMF Pulse END SELECT ENTER ENTER Slot No Port No Slot numbers and port numbers are entered as two digit numbers e g 04 for slot 4 Available Slot Entry Values Slot Number Support...

Page 20: ...ENTER ENTER ENTER 01 12 Month NEXT 001 System Speed Dialling Number 001 000 999 Speed Dialling No Telephone No Max 32 digits END ENTER ENTER CANCEL NEXT To the Next Speed Dialling No To the Desired S...

Page 21: ...nsion PIN of the PBX The cost of such calls will be billed to the owner renter of the PBX To protect the PBX from this kind of fraudulent use we strongly recommend a Keeping PINs secret b Selecting co...

Page 22: ...010 2 2 decimal places Margin XX YY END ENTER ENTER 011 Charge Tax 011 01 03 Location No 2 2 decimal places Tax XX YY END ENTER ENTER 012 Charge Rate per Unit 012 01 64 Trunk Group No Max 8 digits in...

Page 23: ...e Service Switching Mode 101 Manual Automatic END SELECT AUTO ANS MESSAGE ENTER ENTER 102 Time Service Starting Time In 12 hour Format 102 01 00 12 59 Hour Minute END ENTER ENTER Day No Time No 0 Sun...

Page 24: ...nk Group No END ENTER ENTER 01 64 01 64 110 System Password for Administrator for PT Programming 110 4 10 digits Password END ENTER ENTER 1234 111 System Password for User for PT Programming 111 4 10...

Page 25: ...N or extension PIN of the PBX The cost of such calls will be billed to the owner renter of the PBX To protect the PBX from this kind of fraudulent use we strongly recommend a Keeping PINs secret b Sel...

Page 26: ...190 Main Processing MPR Software Version Reference 190 Reference only MPR Version END ENTER 26 PT Programming Manual 2 1 4 System Management Programming...

Page 27: ...3 Intercept Time 203 END ENTER ENTER 1 240 s Time 1 Day 2 Lunch 3 Break 4 Night Time No Time No 204 Hot Line Waiting Time 204 0 15 s Time END ENTER ENTER 205 Automatic Redial Repeat Times 205 0 10 Num...

Page 28: ...60 s Time END ENTER ENTER 209 DISA Delayed Answer Time 209 0 30 s Time END ENTER ENTER 210 DISA Trunk to Trunk Call Prolong Time 210 0 7 min Time END ENTER ENTER 211 DISA Intercept Time 211 0 60 s Ti...

Page 29: ...e Next Location No To the Desired Location No 302 TRS Barring Exception Code 302 2 6 Level No Max 16 digits Exception Code 001 100 Location No END ENTER ENTER 303 Special Carrier Access Code 303 Max 1...

Page 30: ...ENTER ENTER 330 ARS Routing Plan Time Table In 12 hour Format 01 16 Plan Table No 01 12 00 59 Hour Minute 0 Sun 1 Mon 2 Tue 3 Wed 4 Thu 5 Fri 6 Sat Day No END 1 TimeA 2 TimeB 3 TimeC 4 TimeD ARS Time...

Page 31: ...0 characters Name END ENTER ENTER 351 ARS Trunk Group for Carrier Access Disable Enable SELECT 351 Carrier Table No Trunk Group No END ENTER ENTER SELECT 01 10 01 64 352 ARS Removed Number of Digits f...

Page 32: ...characters Name END ENTER ENTER 3 digits Trunk No 402 LCOT BRI Trunk Group Number 402 01 64 3 digits Trunk Group No END ENTER ENTER Trunk No 409 LCOT BRI Trunk Number Reference 409 Reference only Slot...

Page 33: ...ion Time Incoming 414 END ENTER ENTER 0 None 1 6 5 2 113 N 1 8 ms Slot No Port No Mode No 415 LCOT Reverse Circuit 415 Disable Outgoing Both Call END SELECT ENTER ENTER Slot No Port No 416 LCOT Pause...

Page 34: ...r 422 Slot No Port No Max 16 digits Subscriber No END ENTER ENTER 424 BRI Layer 1 Active Mode 424 Slot No Port No Permanent Call by call END SELECT ENTER ENTER Note After changing this setting perform...

Page 35: ...R Clear for Automatic Note After changing this setting perform 902 Slot Card Reset to enable the new setting 450 DIL 1 1 Destination 450 END ENTER ENTER Time No Slot No Port No Destination No 1 Day 2...

Page 36: ...n No Max 10 digits Host PBX Access Code END ENTER ENTER 01 64 472 Extension to Trunk Call Duration 472 Trunk Group No 01 60 min Time END ENTER ENTER 01 64 473 Trunk to Trunk Call Duration 473 Trunk Gr...

Page 37: ...ISA Cyclic Signal Detection 477 Trunk Group No No Detect Detect END SELECT ENTER ENTER 01 64 490 Caller ID Signal Type ENTER ENTER 490 Slot No FSK FSK with Visual Caller ID DTMF SELECT END 491 Pay Ton...

Page 38: ...No Page up 01 64 501 TRS Barring Level 501 01 64 COS No Time No 1 7 Level END ENTER ENTER 1 Day 2 Lunch 3 Break 4 Night 502 Trunk Call Duration Limitation 502 01 64 COS No END ENTER ENTER SELECT Disab...

Page 39: ...No END ENTER ENTER 508 Account Code Mode 508 01 64 COS No END Option Forced SELECT ENTER ENTER 509 TRS Barring Level for System Speed Dialling 509 01 64 COS No 1 7 TRS Barring Level END ENTER ENTER 5...

Page 40: ...ching 514 01 64 COS No END Disable Enable SELECT ENTER ENTER 515 Wireless XDP Parallel Mode for Paired Telephone SELECT Disable Enable 515 01 64 COS No END ENTER ENTER 516 Programming Mode Limitation...

Page 41: ...elephone all SDN buttons customised for that device will be deleted 602 Class of Service 602 01 64 COS No END ENTER ENTER Extn No 1 5 digits 603 Extension User Group 603 Extn User Group No END ENTER E...

Page 42: ...roup Delayed Ringing 621 Location No END Immediate 1 6 rings No ring SELECT ENTER ENTER Incoming Call Distribution Group No 001 128 01 32 622 Incoming Call Distribution Group Floating Extension Number...

Page 43: ...No Incoming Call Distribution Group No 001 128 626 Overflow Time 626 1 125 10 s 001 128 Overflow Time END ENTER ENTER Incoming Call Distribution Group No 627 Destination When All Busy 627 Max 32 digit...

Page 44: ...in Queuing Time Table 631 01 16 Number must be entered in the N Location No Table No END None Overflow Disconnect N 5 s Sequence N OGM N SELECT ENTER ENTER 01 64 632 Maximum Number of Agents 632 No Li...

Page 45: ...Pickup Group 650 Pickup Group No END SELECT ENTER ENTER No Yes Extn User Group No 01 64 001 032 660 VM Group Floating Extension Number 660 1 2 VM DPT Group No END ENTER ENTER Extn No 1 5 digits 680 Id...

Page 46: ...desired language Press F for 2 seconds C Tone C Tone Note For details about PS registration refer to the Quick Installation Guide for the relevant Cell Station CS 691 PS Termination 691 PS No END ENT...

Page 47: ...0 END External Internal1 Internal2 ENTER ENTER SELECT AUTO ANS MESSAGE 711 Music on Hold 711 END 0 Tone 1 BGM 1 2 BGM 2 Music Source No ENTER ENTER 712 Music for Transfer 712 END Hold Music Ring back...

Page 48: ...going Message OGM Floating Extension Number 730 END Message No ENTER ENTER Extn No 01 64 1 5 digits 731 Outgoing Message OGM Name 731 END Message No Max 20 characters Name ENTER ENTER 01 64 732 DISA S...

Page 49: ...ps 2 Location ENTER ENTER SELECT 800 RS 232C Parameter Word Length 800 END 7 8 bits SELECT 3 Location ENTER ENTER 800 RS 232C Parameter Parity Bit 800 END None Mark Space Even Odd SELECT 4 Location EN...

Page 50: ...int Print SELECT ENTER ENTER 805 SMDR Incoming Call Printing 805 END No print Print SELECT ENTER ENTER 810 Remote Programming Disable Enable SELECT 810 END ENTER ENTER 811 Modem Floating Extension Num...

Page 51: ...t No CANCEL NEXT Confirming the deleting operation 902 Slot Card Reset 902 END Slot No Reset ENTER ENTER Confirming the resetting operation 910 OPB3 Option Card Type Reference 910 END Slot No Referenc...

Page 52: ...52 PT Programming Manual 2 1 12 Card Programming...

Page 53: ...Feature Programming References PT Programming Manual 53...

Page 54: ...emoved Number of Digits for Carrier Access 353 ARS Carrier Access Code Feature Guide References 1 10 1 Automatic Route Selection ARS Call Charge Services 010 Charge Margin 011 Charge Tax 012 Charge Ra...

Page 55: ...Name Feature Guide References 1 1 1 5 Calling Line Identification CLI Distribution Calling Party Control CPC Signal Detection 413 LCOT CPC Signal Detection Time Outgoing 414 LCOT CPC Signal Detection...

Page 56: ...ination Feature Guide References 1 1 1 2 Direct In Line DIL Direct Inward Dialling DID Direct Dialling In DDI 421 BRI DIL DDI MSN Selection 451 DID Number 452 DID Name 453 DID Destination Feature Guid...

Page 57: ...ne Call Destination 729 Doorphone Number Reference Feature Guide References 1 17 1 Doorphone Call Emergency Call 304 Emergency Number Feature Guide References 1 5 4 2 Emergency Call Executive Busy Ove...

Page 58: ...ering Floating Extension 623 Incoming Call Distribution Group Name 660 VM Group Floating Extension Number 700 External Pager Floating Extension Number 730 Outgoing Message OGM Floating Extension Numbe...

Page 59: ...Name 624 Incoming Call Distribution Group Distribution Method 625 Destination for Overflow Time Expiration 626 Overflow Time 627 Destination When All Busy 628 Queuing Call Capacity 629 Queuing Hurry u...

Page 60: ...205 Automatic Redial Repeat Times 206 Automatic Redial Interval Feature Guide References 1 6 1 4 Last Number Redial Line Preference Outgoing 103 Idle Line Access Local Access 500 Trunk Group Number Fe...

Page 61: ...coming Call Distribution Group 620 Incoming Call Distribution Group Member 621 Incoming Call Distribution Group Delayed Ringing 622 Incoming Call Distribution Group Floating Extension Number 624 Incom...

Page 62: ...System Speed Dialling Number 002 System Speed Dialling Name 004 Extension Name Feature Guide References 1 25 3 PS Directory PS Ring Group 620 Incoming Call Distribution Group Member Feature Guide Refe...

Page 63: ...Access Code Feature Guide References 1 5 4 9 Special Carrier Access Code Speed Dialling Personal System 001 System Speed Dialling Number 002 System Speed Dialling Name 509 TRS Barring Level for Syste...

Page 64: ...ice Toll Restriction TRS Call Barring Barring 300 TRS Barring Override by System Speed Dialling 301 TRS Barring Denied Code 302 TRS Barring Exception Code 501 TRS Barring Level 509 TRS Barring Level f...

Page 65: ...dentification Number PIN 123 Verification Code COS Number Feature Guide References 1 9 6 Verification Code Entry Virtual PS 690 PS Registration Feature Guide References 1 25 6 Virtual PS Voice Mail VM...

Page 66: ...one Feature Guide References 1 28 3 Walking Extension Wireless XDP Parallel Mode 515 Wireless XDP Parallel Mode for Paired Telephone Feature Guide References 1 25 5 Wireless XDP Parallel Mode 66 PT Pr...

Page 67: ...PT Programming Manual 67 Notes...

Page 68: ...be reproduced for internal use only All other reproduction in whole or in part is prohibited without the written consent of Panasonic System Networks Co Ltd Panasonic System Networks Co Ltd 2011 DD04...

Reviews: