background image

2012

©

Panasonic Corporation Power Components Business Unit

1048,kadoma,kadoma,oosaka,571-8686,japan  Tel81-06-6908-1131

Instruction Manual

Factory Line 20

For keeping

■Be sure to read this Instruction Manual before use, and then properly use the product.
■Ask an electrical contractor for troubleshooting and maintenance such as expansion of this product. In 

such case, be sure to pass these Instruction and Installation Manuals to the contractor.

■Mounting additional outlet plug requires no qualification as an electrical worker.
 Note:Before mounting/dismounting or relocating plugs, be sure to turn OFF power supply
■Be sure to keep this Instruction Manual for future reference, and be sure to hand this manual to user.

There is longevity in Factory Line 20, and a standard use period is ten years. It becomes impossible to use finally due 

to the deterioration of internal if it uses it exceeding the service life. Deterioration advances every year though it differs 

in the environmental condition and the service space. In order to use the factry-line for a long time,Please contact the 

specialist in the construction shop etc. when it checks, and trouble is found, and receive the check by the specialist in 

the construction shop etc. once every three years. Please be sure to observe the following, and the check.

The precautions describe what must be observed not to harm humans nor cause property damage.

Safety precautions

  

Be sure to observe the precautions fully

 

Warning

● Do not modify to products in any way.

may cause fire, electric shock or damage due to falling 
of equipment. 

● Do not  install parts of incompatible.

may cause fire, electric shock or damage due to falling 
of equipment.

● Do not mount any bracket other than dedicated  

bracket to the Factory Line 20, or do not apply 

weight exceeding that of the dedicated bracket 

(allowable suspension load of hanger: 10 kg) to 

the Factory Line.

Doing so will result in a drop.

● Do not install the illuminator that becomes a high 

temperature like the white heat ball etc.

 Not doing so will result in an electric shock, a fire.

● If any abnormality occurs, immediately turn OFF the 

power supply, and then contact your electrical worker 

to take necessary actions.(In such case, be sure to 

pass Instruction and Installation Manuals )

Not doing so will result in an electric shock, a fire, or a drop.

● Use the rated voltage within the load capacity that is 

always displayed.

Not doing so will result in a fire.

● Use Fluorescent lighting plug below a permissible load.

Not doing so will result in a fire, or a drop.

Caution

● this product is dedicated to ordinary indoor use, Do not 

use it at the place which is subject to the influence of heat, 

such as the upper part of a heater, or  a place with moist 

place and vibration, which receives blowing in of rain, and 

a moist,,where corrosive gas, where the smoke rises

・A place with moist place and vibration

・A place which receives blowing in of rain, and a moist place

・A place where corrosive gas, where the smoke rises

・The place which is subject to the influence of 

heat, such as the upper part of a heater

Not doing so will result in an electric shock, a fire, or a drop.

● Do not slide putting the plug in the duct

Poor contact will cause a fire.

● Do not slide putting the plug in the duct

Not doing so may result in an electric shock or a fire.

● Do not pull the plug cable.

Doing so may result in faulty connection, thus leading to 
a fire.

● Before check for the product, be sure to turn OFF 

the power supply.

Not doing so may result in an electric shock.

● If an earthquake occurs, turn OFF the power supply, 

and then ensure that thorough mounting strength is 

provided.If NOT, consult with your electrical contractor. 

In such case, be sure to pass these Installation and 

Instruction Manuals to the contractor.

Not doing so will result in a drop.

● Use the range of -10 ℃ ~ 40 ℃ ambient 

temperature

The use without of range, burn, or cause a fire.

● Attach the plug in the right direction.

If it attaches to reverse, it will become a cause of an electric 
shock, a fire, and fall. 

● Do not apply directly weight to an outlet of the outlet 

plug and the reeler outlet plug.

Not doing so will result in an electric shock, a fire, or a drop.

● Use this product for the transmission of information, 

The transmission performance might be deteriorated 

because of the signal decay in connected part.

● There is longevity in Factory Line 20, and a standard 

use period is ten years.

Even if abnormality is not found in externals, the check 
exchange is done internally because it is deteriorated.

Summary of Contents for Factory Line 20

Page 1: ...your electrical worker to take necessary actions In such case be sure to pass Instruction and Installation Manuals Not doing so will result in an electric shock a fire or a drop Use the rated voltage within the load capacity that is always displayed Not doing so will result in a fire Use Fluorescent lighting plug below a permissible load Not doing so will result in a fire or a drop Caution this pr...

Page 2: ...he smoke rises The place which is subject to the influence of heat such as the upper part of a heater Not doing so will result in an electric shock a fire or a drop Do not install the Factory Line duct passing through building structure Doing so may result in a fire Do not slide putting the plug in the duct Poor contact will cause a fire During construction Do not give a shock such as dropping on ...

Page 3: ...ceiling side directly Are there loose the screw Retighten Are there discoloration or deformation in the plastic of the duct and Change it Are there adhesion and deposition of dust in the inside of a duct Remove the dirt Is a straight line connecting duct Attachment is improved so that it may become a straight line Is the thing which is not an exclusive plug attached to the duct Exchange plugs The ...

Page 4: ... mm mount the flange and then mount a pipe to the flange Unit mm Mounting the ducts directly to the ceiling Support spacing for the duct 1 Turn the flange cover to the left to remove it 2 Use the wood screw or tapping screw then mount the flange to a structural member 3 Align the pipe mounting hole of the pipe suspension hanger with the position of the pan head machine screw to put the pipe in the...

Page 5: ...via the pipe suspended hangers method for bringing in the power supply Route the cable from the ceiling into the pipe When doing this it is easier if the cable is passed through the pipe before securing the Factory Line 20 duct in the hanger Following the same procedure for Step fit the duct in the hanger and then fix it with the cap Use single conductor cables of 1 6 or 2 0 m in size Make wire co...

Page 6: ... duct into the hanger and then turn the cap to the right and tighten the securing screw in order to secure the duct Ensure the strength of building structures enough to support the hanging weight a maximum of 10 kg per support Not doing so may cause the hanger to drop To use long hanger bolts mount these bolts using sway braces Use two or more pieces of hanger for one duct It will become a cause o...

Page 7: ...rew During construction Do not give a shock such as dropping on a product or hitting It may be damaged Combine the tip of a duct and connect certainly Connect a straightly both of the duct Securely fasten the set screws Proper torque 0 98 N m 1 32 N m Doing so may result in an electric shock or a fire When cutting the ducts use a metal hacksaw hand type and cut with the opening in the duct facing d...

Page 8: ...y cable of the grounded side to the Polarity indication ground side the terminal screw of which is plated Caution Set screw Polarity indication ground side Polarity indication ground side Duct Duct Grund terminal M4 Terminal screw plated To connect the duct with the center feed in joiner be sure to align the Polarity indication ground side with each other Only to make connection the cover needs no...

Page 9: ...ng so may result in a fire Do not slide the plug with having come in the duct Doing so may result in faulty connection thus leading to a fire Caution Notes Do not attach the plug unit where the tapping screw is used the duct directiy Notes Do not attach the plug unit where the tapping screw is used the duct directiy 1 2 3 4 5 Do not slide the plug with having come in the duct Doing so may result in ...

Page 10: ...g the lever duct outlet plug lever lock Notes Do not attach the plug unit where the tapping screw is used the duct directiy Do not slide the plug with having come in the duct Doing so may result in faulty connection thus leading to a fire Caution 13 Mounting an electrical outlet plug Mounting plug Matching the polarity indications on the duct and the plug insert the plug into the duct and rotate it...

Page 11: ...ut Fluorescent lighting plug Power supply hole Locknut Mounting fluorescent lighting fixture to the duct fluorescent lighting plug and clamp lever handling method To mount Rotate clockwise until the lever no longer rotates To dismount Rotate counterclockwise until the lever no longer rotates To connect the cable to unthreaded terminal use bar type crimp style terminal Not doing so may result in fault...

Page 12: ...oster might discolor and begins to burn because of the heat of the illuminator Caution Duct Opening Duct cover Use the poster clip to suspend a work instruction sheet or process chart from the Factory Line 20 Fold down about 10 mm of the top of the work instruction sheet or process chart and slide it sideways into the poster clip The work instruction sheet can be positioned in the desired directio...

Reviews: