background image

Model No.

ET-EMF510C

Operating Instructions

Replacement Filter Unit 

Commercial Use

Thank you for purchasing this Panasonic product.

 

Carefully read through these Operating Instructions and the operating instructions of the 
projector to ensure safe and proper operation.

 

Please save this manual for future use.

Attention

 

Turn the main power off before replacing the air filter unit.

 

Make sure that the projector is stable when attaching the air filter unit, and work in an 
environment that is safe, even in the event of the air filter unit dropping.

Replacing the air filter unit

1 ) 

Turn off the projector and disconnect the power plug from the wall outlet.

 

When the power is to be turned off, be absolutely sure to follow the procedure 
described in “Switching off the projector” in the operating instructions of the projector.

2 ) 

Remove the air filter cover.

 

Remove the air filter cover by turning the air filter cover 
fixing screw counterclockwise using the Phillips head 

screwdriver until it turns freely.

3 ) 

Remove the air filter unit.

 

While gently pressing the area near the center of 
the frame on the lens side (front side) of the air 

filter unit toward the inside as shown by the arrow, 
disengage the frame from the projector tabs, 

and draw it out. Then disengage the frame on 

the other side from the tabs, and take out the unit.

 

After taking off the air filter unit, remove any 

accumulations of dust and dirt on the area of the 

projector where the air filter unit is stowed and on the 

air intake of the projector.

Attention

 

Take care not to touch the radiator fins or other parts when removing the dust and dirt.

Air filter cover

Air filter cover fixing screw

Air filter unit

Area where the air filter unit is stowed

and air intake of the projector

Projector tabs

Projector tabs

TQZJ435-1

Reviews: