background image

Operating Instructions

Air Conditioner

 

操作說明書
空調器

2-13

在操作空調器前, 請細讀此操作說明, 並保存此書以備
日後參考。
附帶的安裝說明須保存並請安裝人員在安裝前閲讀。
遙控器包裝在室内機箱子裏並請安裝人員在安裝前取出。

Operating Instructions
Air Conditioner

14-25 

Before operating the unit, please read these operating 
instructions thoroughly and keep them for future reference.
The included Installation Instructions should be kept and read 
by the installer before installation.
Remote control is packaged in the indoor unit and removed 
by the installer before installation.

Model No.
Indoor Unit 

Outdoor Unit

CS-YS9UKA
CS-YS12UKA

CU-YS9UKA
CU-YS12UKA

ACXF55-17450

English

中文

Summary of Contents for CS-YS9UKA

Page 1: ...ructions thoroughly and keep them for future reference The included Installation Instructions should be kept and read by the installer before installation Remote control is packaged in the indoor unit...

Page 2: ...2 1 2 3 1 2 AAA R03 3 A 1 5 12 am pm 24 2 8 AIR SWING ON OFF SET CANCEL TIMER TEMP OFF ON MODE SLEEP POWERFUL QUIET FAN SPEED AIR SWING ON OFF CANCEL TIMER SLEEP POWERFUL QUIET FAN SPEED A B...

Page 3: ...3 4 5 6 7 8 9 10 12 13 AAA R03 2 2 B 1 MODE DRY AUTO COOL 2 OFF ON POWER 3 TEMP 16 0 C 30 0 C 60 F 86 F 10 C F Panasonic...

Page 4: ...4...

Page 5: ...5 ON Ni Cd ELCB RCD ELCB GB...

Page 6: ...6 AUTO AUTO FAN FAN SPEED To adjust airflow direction AIR SWING QUIET 15 POWERFUL AIR SWING ON OFF SET CANCEL TIMER TEMP OFF ON MODE SLEEP POWERFUL QUIET FAN SPEED POWER TIMER...

Page 7: ...7 SLEEP POWERFUL QUIET POWERFUL QUIET 0 5 1 2 3 4 5 6 7 8 9 OFF 0 0h SLEEP ON OFF TIMER CANCEL SET CANCEL 2 1 3 1 ON OFF 22 00 OFF Cancel 2 3 ON OFF ON OFF ON OFF...

Page 8: ...8 AUTO POWER COOL DRY COOL 26 0 C 28 0 C 79 F 82 F COOL DRY AUTO C F DBT WBT DBT WBT COOL 32 89 6 23 73 4 43 109 4 26 78 8 16 60 8 11 51 8 16 60 8 11 51 8 DBT WBT...

Page 9: ...9 H99 pH 7 40 C 104 F 2 2 CZ SA31P 6 1 2 1 2 3 4...

Page 10: ...10 POWER ON ON 15 TIMER COOL...

Page 11: ...11 AUTO OFF ON 1 2 AUTO 3 COOL 4 5 OFF ON COOL 15 COOL 8 C 14 4 F...

Page 12: ...5 2 1 5 3 4 4 H 00 H 11 H 12 H 14 H 15 H 16 CT H 17 H 19 H 21 H 23 1 H 24 2 H 25 H 26 ION H 27 H 28 1 H 30 H 31 H 32 2 H 33 H 34 H 35 H 36 H 37 H 38 H 39 H 41 H 50 H 51 H 52 H 58 H 59 H 64 H 67 nanoe...

Page 13: ...13 Pb...

Page 14: ...ol 2 Insert AAA or R03 batteries 3 Close the cover A Clock setting 1 Press and set the time Press and hold for approximately 5 seconds to show time in 12 hour am pm or 24 hour indication 2 Confirm Use...

Page 15: ...may differ from the actual unit They are subject to change without notice for future improvement B Basic operation 1 Press MODE to select the desired mode DRY AUTO COOL 2 Press OFF ON to start stop t...

Page 16: ...or flammable atmosphere Failure to do so could result in fire Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit rotating parts may cause injury Do not touch t...

Page 17: ...fire Prevent electric shock by switching off the power supply and unplug Before cleaning or servicing When extended non use or During abnormally strong lightning activity CAUTION Indoor unit and outd...

Page 18: ...ust the flap by hand For lateral direction it is manually adjustable as shown AIR SWING Upper direction AIR SWING ON OFF SET CANCEL TIMER TEMP OFF ON MODE SLEEP POWERFUL QUIET FAN SPEED Not used in no...

Page 19: ...the clock set in the remote control and repeats daily once set For clock setting please refer to Quick Guide 2 sets of ON and OFF timers are available to turn ON or OFF the unit at different preset t...

Page 20: ...rection In COOL DRY mode If AUTO is set the flaps swings up down automatically Auto restart control If power is resumed after a power failure the operation will restart automatically after a period of...

Page 21: ...the filters thoroughly under shade away from fire or direct sunlight Replace any damaged filters Remove air filter Attach air filter Insert into the unit Air Purifying Filter Air Purifying Filter Do...

Page 22: ...e the unit Mist emerges from indoor unit Condensation effect due to cooling process Outdoor unit emits water steam Condensation or evaporation occurs on pipes Discoloration of some plastic parts Disco...

Page 23: ...air inlet and outlet vents Use Auto OFF ON button to select COOL operation After 15 minutes of operation it is normal to have the following temperature difference between the air inlet and outlet ven...

Page 24: ...ming pool sensor H 32 Outdoor heat exchanger temperature sensor 2 abnormality H 33 Indoor outdoor misconnection abnormality H 34 Outdoor heat sink temperature sensor abnormality H 35 Indoor outdoor wa...

Page 25: ...are only valid in the European Union If you wish to discard these items please contact your local authorities or dealer and ask for the correct method of disposal Pb Note for the battery symbol botto...

Page 26: ...Memo...

Page 27: ...Memo...

Page 28: ...Printed in Malaysia ACXF55 17450 SC0218 0 Panasonic Corporation 1006 Kadoma Kadoma City Osaka Japan Website http www panasonic com Panasonic Corporation 2018...