background image

VERTICAL FLOAT SUMP PUMP

Model

Model

Model

95591 - .75 HP

95592  -  1  HP

95593 - 1.5 HP

SET UP And OPERATIng InSTRUCTIOnS

Diagrams within this manual may not be drawn proportionally.

Due to continuing improvements, actual product may differ slightly from the product described herein.

distributed exclusively by Harbor Freight Tools

®

.

3491 Mission Oaks Blvd., Camarillo, CA 93011

Visit our website at: http://www.harborfreight.com

 Read this material before using this product.  

Failure to do so can result in serious injury. 

SAVE THIS MAnUAL.

Copyright

©

 2006 by Harbor Freight Tools

®

.  All rights reserved.  No portion of this 

manual or any artwork contained herein may be reproduced in any shape or form 

without the express written consent of Harbor Freight Tools.

For technical questions or replacement parts, please call 1-800-444-3353.

REV 07l, 08i

Summary of Contents for 95591 - .75 HP

Page 1: ...eight Tools 3491 Mission Oaks Blvd Camarillo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury Save th...

Page 2: ...ollowing pages may result in electric shock fire and or serious injury SAVE THESE INSTRUCTIONS REV 08b 09a SPECIFICATIONS Model 95591 Model 95592 Model 95593 Motor 115 V 60 Hz 4 A 3 4 HP 115 V 60 Hz 5...

Page 3: ...out let only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit con tact a qualified electrician to install a polarized outlet Do not change the plug in an...

Page 4: ...of electric shock or injury SPECIFIC SAFETY RULES Maintain labels and nameplates on 1 the Pump These carry important information If unreadable or miss ing contact Harbor Freight Tools for a replacemen...

Page 5: ...ician install within 10 feet of where the Pump will be located a 115 volt GFCI electrical outlet that is dedicated only to the Pump Any outlet should be above the water line NEVER raise or lower the P...

Page 6: ...nding provides a low resistance path to carry electricity away from the user reducing the risk of electric shock See 3 Prong Plug and Outlet The grounding prong in the plug is 2 connected through the...

Page 7: ...If you are using one extension cord 5 for more than one tool add the nameplate amperes and use the sum to determine the required minimum cord size See Table A If you are using an extension cord 6 out...

Page 8: ...Assembly Diagram on page 13 WARNING Always make sure to turn off the electricity powering the Pump s electrical outlet and that the Pump is unplugged from its outlet prior to assembling the unit uncl...

Page 9: ...e the stability of the Pump See Figure E Install an additional union not included or other means of separating the Dis 4 charge Pipe just above the floor to facilitate removal of the Pump if necessary...

Page 10: ...dry Doing so will increase wear to the unit and possibly cause seal damage See Figure E Note This Pump has a built in thermal protector for the Motor which automatically shuts it off to avoid overhea...

Page 11: ...ON All maintenance service or repairs not mentioned in this manual must only be performed by a qualified service technician TROUBLESHOOTING Problem Possible Solution Pump does not start Plug the Pump...

Page 12: ...AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO PARTS LIST Part Description...

Page 13: ...AGRAM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 32 31 Power Cord Plug not shown Note Some parts are listed and shown for illustration purposes only and are not a...

Page 14: ...perty or for incidental contingent special or con sequential damages arising from the use of our product Some states do not allow the exclusion or limitation of incidental or consequential damages so...

Reviews: