background image

270706-20 PACINSD1  5055.101

MODEL 
PACIFIC WOOD 
INSERT
DESIGN-D

SAFETY NOTICE

If this stove is not properly installed, a house 

fi re may result. For your safety, folow the 

installation directions. Consult local building 

or officials about restrictions and installation 

inspection requirements in your area.

Pacifi c
Wood Insert

IMPORTANT:

THESE INSTRUCTIONS ARE TO 
REMAIN WITH THE HOMEOWNER

INSTALLATION 

AND OPERATING 

INSTRUCTIONS

TESTED and LISTED 
to ULC S628 / UL 1482

Meets the U.S. Environmental Protection 
Agency's July 1990 Particulate Emission
Standards 

Summary of Contents for Wood Insert Design-D

Page 1: ...ation directions Consult local building or officials about restrictions and installation inspection requirements in your area Pacific Wood Insert IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HO...

Page 2: ...on 10 How to Test Your Wood 10 Lighting the Fire 10 Normal Operation 10 Restarting After Extended or Overnight Burns 10 More Wood More Heat 11 Proper Draft 11 Ash Removal 11 Disposal of Ashes 11 Creos...

Page 3: ...rections Consult local building or fire officials about restrictions and installation inspection requirements in your area The services of competent installer certified by the Wood Energy Technical pr...

Page 4: ...ening Ember protection Combustible floor beyond the hearth must be protected from hot embers by non combustible material extending 16 to the firing side and 8 to other sides of the unit Consult CAN CS...

Page 5: ...uitable for wood burning use Check for creosote build up or other obstructions especially if it has not been in use for some time The existing fireplace damper is to be locked open or re moved complet...

Page 6: ...g legs to level the Insert Note For better access the top of the casing may be re moved Fig 4 If it is necessary to get access to the connector pipe through the flue outlet of the Insert the baffle ca...

Page 7: ...e enclosed hardware Slide part F into the back corners of the trim and tighten screws Ensure the mitred corners fit tightly and evenly Fig 6 4 Slide the assembled trim over the surround from the top F...

Page 8: ...erse order to their removal 8 Slide pre assembled surround into the friction fit tabs on the inside of the outer casing DO NOT LIFT THE SURROUND ASSEMBLY BY GRASPING THE TRIM The surround is held in p...

Page 9: ...pply Once removed combustion air is drawn from the room into the lower front of the Insert Removal The O A cover should be removed prior to instal lation For better access tip the Insert onto its back...

Page 10: ...er in the centre of the heater and criss cross with several pieces of dry kindling Add a few small pieces of dry wood on top 3 Ignite the paper and close the door 4 After the fire as established itsel...

Page 11: ...g the smoke the ideal place to condense In summary a certain amount of creosote is inevitable and must be lived with Regular inspection and cleaning is the solution The use of dry seasoned wood and am...

Page 12: ...peed Control Blower Thermo Switch By pass Rocker Switch Chimney Fires The result of excessive creosote buildup is a chimney fire Chimney fires are dangerous Chimney inside temperatures can exceed 2000...

Page 13: ...sing the stove Replacement glass can be obtained from your Dealer The size required is 9 1 8 x 15 5 8 x 5 mm Robax Ce ramic glass must be used Do not substitute with any other type To remove broken gl...

Page 14: ...w Bolt WODC 1461 12 Glass Clamp Set 4 pc SSER 1425 13 Glass Bar Set 2 pc WODC 414001 14 Replacement Glass c w Tape DR31 WGLKIT 15 Door Gasket Kit DR31 WDGKIT 16 Door Casting Arched Black CAST 31ST Do...

Page 15: ...heat storage and the thermal insulation keeps the combustion zone hot Active flaming takes place during the first part of the burn During this storage heat is stored in the mass of the unit and is la...

Page 16: ...ace gasket Check latch Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Area too large 4 Poor insulation or open concrete Won t Burn Overnight 1 Air control set too hi...

Page 17: ...17 NOTES...

Page 18: ...18 NOTES...

Page 19: ...DIRECT FLUE CONNECTION ASSEMBLY OPTIONAL COMPONENTS FAN KIT ELECTRICAL RATING 115V 60HZ 1 AMP ROUTE CORD AWAY FROM UNIT FOR USE WITH SOLID WOOD FUEL ONLY DO NOT USE GRATE OR ELEVATE FIRE BUILD WOOD F...

Page 20: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD www pacificenergy net Technical Support 1 888 715 2398 2975 Allenby Rd Duncan B C V9L 6V8 Printed in Canada...