User Manual

        

OFFICE PRO LCD 

                  English / Français

                                

550VA/750VA 

Inspection

 

The following items are inside the box: 

 

UPS unit       

  User manual   

  USB cable 

Remove the UPS from its package and inspect it for damage that 
may have occurred during shipping.    If any damage is discovered, 
re-pack the unit and return it to the place of purchase. 
 

Connect to Utility Power

 

Connect AC power cord to utility power. Then, the UPS will start to 
charge inside battery. For best result, charge the battery for 6 hours 
prior to initial use. 
   

Plug in Equipment

 

Battery Backup Outlets(4) 

Connect computer and monitor to the "Battery Backup" outlets. 
These outlets provide battery backup, EMI filtering, line 
conditioning, and surge protection. Battery power is automatically 
provided in case of power failure. 

 

 

Surge-Protected Outlets(4) 

Connect a printer, fax machine, or scanner to the “Surge-protected” 
outlets.    These outlets do not provide power during power failure.

 

CAUTION: NEVER 

connect a laser printer or scanner to the 

battery backup sockets of UPS. The equipment may overload the 
UPS. 

ATTENTION : Ne JAMAIS

 raccorder une imprimante laser ou un 

scanner pour les prises de sauvegarde batterie de l’onduleur. 
L’équipement peut surcharger le système UPS. 
 

Turn On/Off the UPS 

To turn on the UPS unit, press the power switch lightly. Then, the   
LCD will light up. To turn off the UPS unit, press the power switch 
again. Then, display will shut off. 

 
 

 

 
 

 

 

Operation Display

 

NOTE:

 If backlight shuts off, you may activate it by touching the 

screen. 

REMARQUE 

: Si le rétro-éclairage s’éteint, vous pouvez l’activer 

en touchant l’écran. 

 

Fault Code Table: 

 

Fault condition 

LCD   

Solutions 

Output short 
circuited 

 

Disconnect short-circuited 
loads and restart the UPS 
again. 

Overload fault 

 

Disconnect all output loads 
and restart the UPS again. 

Overcharge 

 

Call for service immediately.   

Bad or severely 
discharged 
battery 

 

Please replace the battery. 

High output 
voltage fault 

 

Call for service immediately. 

Over-temperature 

 

1.  Turn off the unit and wait 

for cooling. 

2.  Or remove excessive 

loads and wait for 
cooling. 

If fault alarm occurs, please call for service immediately. 
En cas d’alarme de panne, veuillez appeler pour service 
immédiatement. 
 
 

 

 

       

www.orionpowersystems.com 

UPS 

Mode 

LCD 

Description 

UPS 
Power on 

 

When UPS is powered 
on, it will enter this 
mode for 4 seconds. 

AC Mode 

 

 

LCD information will be 
displayed in the 
following order when 
LCD is touched. 
1.  Output voltage 
2.  Input voltage 
3.  Load level 
4.  Battery capacity   
 
 

Overload 
in AC 
mode 

 

  icon will flash. 

When overload occurs, 
alarm will beep every 
0.5 second. 

Battery 
Mode 

 

 

When battery level is low, 

  icon will flash.   

Alarm will beep every 
10 seconds and LCD 
information will be 
displayed in the 
following order when 
LCD is touched. 
1.  Output voltage 
2.  Input voltage 
3.  Load level 
4.  Battery capacity 

Overload 
in battery 
mode 

 

  icon will flash. 

When overload occurs, 
alarm will beep every 
0.5 second. 

INSTALLATION & OPERATION 

PRODUCT OVERVIEW 

1.

 

Touchscreen LCD display 

2.

 

Power switch 

3.

 

AC input 

4.

 

Battery backup outlets 

5.

 

Surge‐protected outlets 

6.

 

USB port 

7.

 

RJ11 / RJ45 

Modem/network 

surge protection 

LCD DISPLAY 