User Manual
OFFICE PRO LCD
English / Français
550VA/750VA
Inspection
The following items are inside the box:
●
UPS unit
●
User manual
●
USB cable
Remove the UPS from its package and inspect it for damage that
may have occurred during shipping. If any damage is discovered,
re-pack the unit and return it to the place of purchase.
Connect to Utility Power
Connect AC power cord to utility power. Then, the UPS will start to
charge inside battery. For best result, charge the battery for 6 hours
prior to initial use.
Plug in Equipment
Battery Backup Outlets(4)
Connect computer and monitor to the "Battery Backup" outlets.
These outlets provide battery backup, EMI filtering, line
conditioning, and surge protection. Battery power is automatically
provided in case of power failure.
Surge-Protected Outlets(4)
Connect a printer, fax machine, or scanner to the “Surge-protected”
outlets. These outlets do not provide power during power failure.
CAUTION: NEVER
connect a laser printer or scanner to the
battery backup sockets of UPS. The equipment may overload the
UPS.
ATTENTION : Ne JAMAIS
raccorder une imprimante laser ou un
scanner pour les prises de sauvegarde batterie de l’onduleur.
L’équipement peut surcharger le système UPS.
Turn On/Off the UPS
To turn on the UPS unit, press the power switch lightly. Then, the
LCD will light up. To turn off the UPS unit, press the power switch
again. Then, display will shut off.
Operation Display
NOTE:
If backlight shuts off, you may activate it by touching the
screen.
REMARQUE
: Si le rétro-éclairage s’éteint, vous pouvez l’activer
en touchant l’écran.
Fault Code Table:
Fault condition
LCD
Solutions
Output short
circuited
Disconnect short-circuited
loads and restart the UPS
again.
Overload fault
Disconnect all output loads
and restart the UPS again.
Overcharge
Call for service immediately.
Bad or severely
discharged
battery
Please replace the battery.
High output
voltage fault
Call for service immediately.
Over-temperature
1. Turn off the unit and wait
for cooling.
2. Or remove excessive
loads and wait for
cooling.
If fault alarm occurs, please call for service immediately.
En cas d’alarme de panne, veuillez appeler pour service
immédiatement.
www.orionpowersystems.com
UPS
Mode
LCD
Description
UPS
Power on
When UPS is powered
on, it will enter this
mode for 4 seconds.
AC Mode
LCD information will be
displayed in the
following order when
LCD is touched.
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity
Overload
in AC
mode
icon will flash.
When overload occurs,
alarm will beep every
0.5 second.
Battery
Mode
When battery level is low,
icon will flash.
Alarm will beep every
10 seconds and LCD
information will be
displayed in the
following order when
LCD is touched.
1. Output voltage
2. Input voltage
3. Load level
4. Battery capacity
Overload
in battery
mode
icon will flash.
When overload occurs,
alarm will beep every
0.5 second.
INSTALLATION & OPERATION
PRODUCT OVERVIEW
1.
Touchscreen LCD display
2.
Power switch
3.
AC input
4.
Battery backup outlets
5.
Surge‐protected outlets
6.
USB port
7.
RJ11 / RJ45
Modem/network
surge protection
LCD DISPLAY