background image

Smart Touch 

Thermostat

Colour 
Touchscreen 
Thermostat 

OBSMART

Summary of Contents for Smart Touch

Page 1: ...Smart Touch Thermostat Colour Touchscreen Thermostat OBSMART ...

Page 2: ...s we supply include as much information as possible to ensure that all installations comply with current electrical regulations Please call our customer support line if in any doubt on 0845 208 0221 The Orbry Smart Touch Thermostat is a digital thermostat which is designed for electric underfloor heating systems with a maximum load of up to 16A 3600W The Orbry Smart Touch features a 4 3 colour tou...

Page 3: ...e the face plate Step 2 Disconnect ribbon cable remove face plate The sensor conduit and deep back box must be fitted before installation of the actual thermostat can begin Feed the sensor probe provided down through the sensor conduit into a representive area of the floor For technical advice or help with any queries please call our customer support team on 0845 208 0221 or visit www orbry com or...

Page 4: ...e Orbry Smart Touch is securely fixed before continuing Faceplate Provided screws Ribbon connectors Back plate Back box Wire and replace the face plate Sensor 7 6 4 3 2 1 5 L L 3600W 16A 230V AC N N Loosen the tension screws to allow the wires to be inserted and fixed Position the cables as shown in the wiring diagram and ensure each screw is tightened correctly Ensure system is correctly earthed ...

Page 5: ...icon Mode button Weekday icon Down button Clock icon Mode icon Set temperature Floor temperature Mode icon area ROOM 5 4 1 1 8 2 9 3 10 4 11 5 12 6 13 7 14 2 3 14 13 12 11 10 9 8 7 6 Orbry Smart Touch Thermostat Interface On Off button PROGRAMMING THE ORBRY SMART TOUCH ...

Page 6: ...ically maintain a preset low energy saving temperature e g 8 C while you re away Boost mode Set a high temperature e g 27 C and quickly switch to this high temperature on demand Preset temperatures Use to define pre set temperatures Program review Use to check your 5 1 1 day schedule Date time button Use to set the correct weekday and time Protection temperatures Use to define minimum and maximum ...

Page 7: ...ge as shown Every setting can be edited using the or buttons In the Sun column there are six 6 periods You can press the or buttons to choose the period you are going to change The button will display beside the period selected Finally press APPLY to save your new schedule Next you can set the start time and desired temperature by pressing the and buttons Schedule settings RETURN RETURN PROGRAMMIN...

Page 8: ...on to select a mode Now edit that mode setting s temperature using the and buttons Press APPLY to save the changes Press the MENU button then the button to enter the language page Choose the desired language and press APPLY to save the changes Edit date time Preset temperature mode Language select PROGRAMMING THE ORBRY SMART TOUCH RETURN RETURN RETURN ...

Page 9: ...ture and set a limit defined by you If the system reaches the set protection temperature the system will shut off automatically Low protection This is a frost protection mode designed to function when the Orbry Smart Touch is switched off If the ambient temperature reaches the set protection temperature the system will automatically switch on to maintain a minimum temperature Please note The upper...

Page 10: ...u 01 8 C 8 C Temperature Offset 03 5 C 35 C Set Point Maximum 05 I only E only I E I or E NTC Select Ambient I Floor E 07 5 C 10 C Low Protection Minimum 09 5 C 90 C High Protection Minimum 11 1 100 Min Backlight Brightness of Standby Status 13 Normal NO Inverted NC Relay Output 02 0 C 3 C Dead Zone 04 5 C 35 C Set Point Minimum 06 5 C 10 C Low Protection Maximum 08 5 C 90 C High Protection Maximu...

Page 11: ...Dimensions Sensor 7 6 4 3 2 1 5 L L 3600W 16A 230V AC N N 94mm 60mm 52mm 50mm 31mm 19mm 130mm 87mm 4 3 TECHNICAL SPECIFICATIONS ...

Page 12: ...mbient and or floor sensors Four languages English French German and Dutch Clock and date display Temperature calibration Overheat and frost protection modes Single gang extra deep back box www orbry com info orbry com 0845 208 0221 Voltage Maximum load Temperature range Ambient Sensor Accuracy Warranty IP Rating Width Height Depth 230V 50 60Hz 16A 3600W 5 35O C 0 50O C NTC 10k 10kΩ at 25O C 0 5O ...