background image

 

Adres: Marssteden 61, 7547 TE  Enschede.  
Mail:    

[email protected]

 

Tel:      053-3030220 

Vs 1.3 

ORL Ekra 20/40/DC residential luminaire 

 

Mounting Instruction 

 

1.

 

Post top diameter: 

 60 mm 

 

2.

 

Protection grade:

 IK10, IP66  

 

3.

 

Certifications:

 CE, ENEC, Dekra Led Perf. 

 

4.

 

Needed tools:

  

- 4mm allen wrench 

- 10mm allen wrench 

5.

 

Installation order: 

a.

 

Make sure power is off when starting. 

b.

 

Unpack the luminaire.  

c.

 

Guiding the power cable into the pole, and 
position the luminaire on top of the pole. 

d.

 

Position the luminaire with the arrow and  
Orange Lighting brand logo on canopy to  
the street side and tighten the 6 bolts with  
a 4mm allen wrench with a torque value  
of 5Nm. 
 

6.

 

Repair or Maintenance 

a.

 

Make sure power is off when starting. 

e.

 

Secure the fixtures upper side with one  
hand and use a 10mm Allen wrench to  
untighten the fixation cap with your other  
hand by turning anti-clockwise. 

f.

 

Lift up the canopy with two hands. 

g.

 

The canopy can be secured by putting the  
hook on the inner side of the canopy 
inside  
the recessed border of the fixture. 

h.

 

By closing the canopy position the arrows  
of the canopy in line with the mark on the  
luminaire. Secure the luminaire upper side  
with one hand and use a 10mm allen  
wrench to tighten the fixation cap with  
your other hand by turning clockwise with  
a torque value of 20Nm.  Tighten the cable  
gland with the tubular box spanner to  
secure the cable gland. 

20Nm 

5Nm 

Reviews: