background image

Summary of Contents for CK2

Page 1: ...anual is for use of the Inverted Micro scope Model CK2 Before putting the microscope into operation we recommend you read this manual carefully in order 0 familiarize yourself fully with the use of th...

Page 2: ...g 1 Fig 2 s c II Maintenance and sto CD lens surfaces must ajways be kept clean F ne dust on lens surfaces should be blOWll off by means of Mild blower Carefully Wipe off 011 or flngerpnnts on the len...

Page 3: ...NFIGURATIONS 2 2 3 NOMENCLATURE 3 4 OPERATION 4 I 4 1 Assembly and Operation of Each Component 4 I 4 2 Phase Contrast Observation 7 5 PHOTOMICROGRAPHY 8 J 5 1 Photomicrographic System and Optional Acc...

Page 4: ...ser Ultra Iong work ing distance condenser NA 0 3 W O 72 mm detaChable Optics for observation Afacal optical system Inclined 45 interpupillary distance adjustment range 53 through 72 mm With a di Bino...

Page 5: ...0 0 0 DIOX 0 0 0 0 PCSPlan 4XPL 0 0 0 0 Objectives PC010XPL 0 0 0 0 LWDCD20XPL 0 0 0 0 lWOCD20X 0 0 LWQCDPlan4QXPL 0 0 Phase slider CK2 SL 0 0 0 0 Phaseanoular ring for CK2 RS40 0 0 40X objective LB...

Page 6: ...erasaki holder and slide glass holder Filter holder for 45mm dia filter Use the cobalt filter 45Cllor brightfield and the green filter IF550l for phase contrast both filters provided Aperture iris dia...

Page 7: ...or left Attach the bulb again perpendiCl llerly FiG 6 If the filament devilles vertically the contact pim tre not in serted completely Pu in the pins completely Fig 6 11 P J1I 001 the contact pins of...

Page 8: ...ig 8 o Inserting the eyepieces Fig 10 Fig 11 Insert the eyep eces into the observatiOn tube lnterpupilliry distance 8dju m J Hold the k rled sliding grips D of the fight and left eyep ece sleevll With...

Page 9: ...iVll performance of lhe inverted micrOSCoPe the high N A objectives are provided with a correction collar D Fig 14 The correction collar is effective with a veueI bottom from 0 to 2mm thickness 11 If...

Page 10: ...on the st and focus on it Remove one of the eyepieces from the observation tube and insert the centering telescope CT 5 CD provided into the observation tube Fig 17 Ascertain that objective magnificat...

Page 11: ...photo tube 4 Looking through the focusing telescope 2 focus on the specimen In CiJSe of long time expolOu ambient light in the room will go through the eyepieces and its image formed on the film plan...

Page 12: ...hase slider is not engaged in cor Ma slider completely until a rect position clicks into position po 7 I Dust or dirt is visible in Dirty specimen Clean specimen field of view Dust on eyepiece Clean e...

Page 13: ...ket M Cords or plugs are not oomected Connect them completely 3 FocuslfIlI 1 Co se adjustment knob is Focus adjustment kn0b5 are t91t Loosen adjustment kllObs tOO tight ened tOO much bl Specimen goes...

Page 14: ...MEMO...

Page 15: ...CO EUROPA GMBH PremisesIGoods delivefy WendenstrMse 1 4 16 D 2O g7 Hamburg Germany Lellllf Postlacn 104908 20034 Hamburg Getmany OlYMPUS AMERICA INC 2 Corporate CenISf Drrve MeMlIe N If 1747 3157 U S...