background image

INSTALLATION AND 

OPERATION MANUAL

Congratulations! You have just 

purchased the finest commercial 

refrigeration available.

ALPA 36

ALPA 77

ALPA 99

ALPA 120

Part Number 100330038

www.ojedausa.com

ALPA SERIES

460 Southport Commerce Blvd. 

Spartanburg SC 29306

Phone: 864-574-6004 

Fax: 864-574-6005

Summary of Contents for ALPA Series

Page 1: ...tions You have just purchased the finest commercial refrigeration available ALPA 36 ALPA 77 ALPA 99 ALPA 120 Part Number 100330038 www ojedausa com ALPA SERIES 460 Southport Commerce Blvd Spartanburg...

Page 2: ...maintained will give you many years of trouble free operation WARNING USE THIS APPLIANCE FOR ITS INTENDED PURPOSE AS DESCRIBED IN THIS MANUAL When using electrical appliances basic safety precautions...

Page 3: ...soap and carefully drying it cover it with a polyethylene film or similar waterproof material The following procedure is recommended for uncrating the unit Remove the outer package by carefully cuttin...

Page 4: ...as air conditioner supply or return grilles vent hoods appliance condenser air intake and discharge outside doors fans or other air movement devices Fig 2 The following horizontal distance should be c...

Page 5: ...n fixed to the inside floor of the unit to prevent their loss during transportation Insert the shelf brackets in the pilaster notches making sure they are at the same level such that the shelves remai...

Page 6: ...achieve the desired product temperature the electronic control is factory adjusted to turn off the refrigeration system at 35 F and start it at 39 5 F When you plug the unit in the control display wil...

Page 7: ...of the unit In the event the evaporator is frozen it can be thawed by emptying the cabinet of product and removing power until the coil is clear The condensing unit can be pulled out sliding it appro...

Page 8: ...act your distributor Verify that the hot air stream from the condenser towards the back of the unit is not directed to other refrigeration units which would compromise their operation Under no circums...

Page 9: ...ing Dirty condensers result in compressor failure product loss and lost sales which are not covered by warranty If you keep the condenser s clean you will minimize your service expense and lower your...

Page 10: ...nance item and will not be covered under warranty The drain lines can also be accessed by removing the bottom panel from the inside of the unit Fig 7 Both holes for the drain lines can be located Fig...

Page 11: ...epairing and replacing at Ojeda USA s option any component with a similar component when upon our examination and to our satisfaction it is determined to be defective This warranty only applies to Oje...

Page 12: ...ating the equipment model and serial number If replacing parts is required do it through your distributor WARNING Always ask for original spare parts AUTHORIZED DISTRIBUTOR ___________________________...