Step  10  –Place  the  access  point  in  the 
opening  of  the  enclosure  (reference 

Figure  5

with the access points LED light closest to the 
key  lock.  If  the  key  is  turned  the  proper 
direction,  the  access  point  should  drop  in  and 
self-center itself so that the feet on the access 
point  falls  into  the  key  slots  on  the  mounting 
plate (reference Figure 5).  
 

 

NOTE:  If  the  access  point  and  key 

slots  do  not  align  properly,  turn  the  key 
180° and repeat step 5. 

 
 
Step 11 – After verifying that the access point 
is properly seated within the opening, turn the 
key  180°  to  lock  the  Access  Point  in  place. 
The key should require minimal effort to turn. If 
excessive  force  is  required  to  turn  the  key, 
verify  that  the  access  point  is  properly  seated 
within  the  opening  and  then  re-try  turning  the 
key. 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 

 

Figure 6

 – 

Insert foam into the conduit connector and pull the data cable through far enough to allow attachment to the access 

point (8" - 10"). Tighten cable clamp around foam fire block so that there are no air gaps. Be careful not to over tighten and 

crush the Ethernet cable(s). 

 
 
 

Page 4 

 

MODEL 1064-00 

Installation Instructions 

 

**** WARNING **** 

 

Please thoroughly read the product warning below 

before installation to provide for a safe work 

environment. 

 

1.  Ceiling mounted products should be installed in accordance with National Electric Code paragraphs 300.10 (Electrical 

Continuity of Metal Raceways and Enclosures) and 300.11 (Securing and Supporting). Independent support wires or 
other  means  must  be  used  for  the  installation  of  this  product  in  the  ceiling.  Acoustical,  suspended,  false,  drop  and 
concealed  spline  ceiling  grid  work  is  not  designed  to  support  the  weight  of  this  product.  Oberon’s  ceiling  mounted 
products  have  four  support  wire  tabs  on  the  back  box.  These  tabs  shall  be  used  for  supporting  the  product  with 
independent  support  wires,  wire  rope,  threaded  rod,  or  other  secure  support  means  of  adequate  gauge  and  fire 
resistance. 

 

2.  When closing the enclosure access door, be sure that the cam lock is completely engaged to prevent the access door 

from accidentally swinging open. 

 

3.  When opening the enclosure door, be sure to support the door to prevent the door from accidentally falling open. 
 
4.  This  enclosure  has  a  maximum  operating  ambient  of  55º  C  (131º  F),  the  temperature  within  the  enclosure  may  not 

exceed this temperature, depending on power dissipation within enclosure. 

 
5.  A  minimum  air  clearance  of  1“  between  the  housing  of  the  access  point  and  the  enclosure  side  walls  must  be 

maintained for the safe operation of the equipment. 

 
6.  This product is intended to be installed by trained personnel. 
 
7.  Only Listed ITE shall be installed within the enclosure. 
 
8.  This product is to be repaired by personnel trained by the manufacturer or returned to the manufacturer for repair or 

replacement. 

 
9.  Maximum weight to be installed in the unit is 25 lbs. 
 
10.  All  knockouts,  openings,  and  holes  shall  be  sealed  with  a  plug  constructed  of  metal,  or  a  non-metal  material  that 

complies with UL 2043 or UL 1479. 

 
11.  All unused mounting holes should be sealed with tape or other material that complies with UL 1479. 
 
12.  If  AC  power  is  used  inside  the  enclosure,  connect  the  ground  wire  to  the  green  ground  screw  located  near  the 

knockout in the backbox. 

Page 1 

 

 

Figure 5 

– Proper positioning of AP within the 1064 enclosure. Note 

that the access point should be located within the AP mount so that the 

LED is located closest to the lock

 