background image

Installation and service must be provided by a qualified installer, 

service agency or the gas supplier.

ADEQUATE FIREPLACE VENTILATION IS REQUIRED FOR SAFETY 

READ INSTRUCTIONS FULLY BEFORE INSTALLING OR OPERATING

INSTALLER:  LEAVE THESE INSTRUCTIONS WITH CONSUMER! 

NOTE:

FOR YOUR SAFETY 

Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance. 
 

FOR YOUR SAFETY 

WHAT TO DO IF YOU SMELL GAS

1.  Do not try to light any appliance. 
2.  Do not touch any electrical switch; do

not use the phone in your building. 

3. Immediately call your gas supplier

from a neighbor’s phone.  Follow the
gas supplier’s instructions. 

4.  If you cannot reach your gas supplier,

call the fire department. 

 
WARNING:  If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life. 

It is the homeowner’s responsibility to assure 

their fireplace has adequate draft 

 

RECOMMENDED BURN –IN PERIOD

Hargrove gas logs are made of special 
refractory materials, which withstand high 
temperatures.  One characteristic of this 
material is retention of moisture.  For this 
reason, we recommend burning the logs for 
only fifteen minutes during the first burning. 
After allowing the logs to cool for at least one 
hour, the set can be burned for any length of 
time. 
 
Hargrove gas logs carry a limited lifetime 
warranty against breakage in the original 
fireplace.  Warranty does not include labor.  
This warranty is void if excessive handling 
after burning causes breakage.  All 
accessories and metal parts carry a two year 
limited warranty in the original fireplace.  
Items will be replaced during this period for 
the cost of shipping. 

INSTALLATION AND OPERATION GUIDE FOR 

HARGROVE GAS LOGS 

System 4 LP 

For all models tested through OMNI-Test Laboratories, Inc., to 

ANSI Z21.60-2003/CGA 2.26-2003, Decorative Appliance for Installation in Solid-Fuel Burning 

Fireplaces.  

For model number and O-TL seal refer to attached nameplate. 

 
 
 
 
 
 
 
 

Hargrove gas logs are made using refractory materials to create the ceramic logs.  Each log is hand-finished to 
assure the most realistic, detailed log available.  The gas log burner system is designed to burn like wood, with 
a smoky flame.  For this reason, the gas log set must be burned only in a fully vented, non-combustible 
fireplace with the 

damper completely open (In the Commonwealth of Massachusetts the damper must 

either be welded in the fully open position or completely removed)

 and the chimney free of any 

obstructions or restrictions.  The fireplace must be designed and approved to burn wood. 
 
The realistic yellow flame produces carbon monoxide and soot.  Under normal conditions, these products are 
exhausted up the chimney.  If fumes or soot, from the gas burning, are evident in the room when the damper is 
fully open it indicates that the fireplace draft is defective.  Do not operate your gas log set until the fireplace draft 
is corrected. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

f i r e - p a r t s . c o m

Summary of Contents for System 4 LP

Page 1: ...etime warranty against breakage in the original fireplace Warranty does not include labor This warranty is void if excessive handling after burning causes breakage All accessories and metal parts carry a two year limited warranty in the original fireplace Items will be replaced during this period for the cost of shipping INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS System 4 LP For all mo...

Page 2: ...e has adequate draft If fumes or soot from the gas burning are evident in the room when the damper is fully open it indicates that the fireplace draft is defective Do not operate your gas log set until the fireplace draft is corrected Consult your fireplace specialist 7 A fireplace screen must be in place when the appliance is operating and unless other provisions for combustion air are provided t...

Page 3: ...600 Each gas log set requires a minimum 16 inch front opening height and minimum 16 inch depth To determine the largest set that will fit in a fireplace the width at the center of the fireplace is the critical dimension Table I below indicates the minimum center width for each size set View is looking down on the fireplace floor To determine center width add front width and back width and divide b...

Page 4: ... Burner Orifice LP not shown 12 Fire Logs Not Shown 13 Regulator Heat Shield 14 Heat Shield for Valve Stem 18CPSF 1B 1H 5 PG 16 5 8 SF 14 EM AC 18 CPC 2 SPC EH RSTPB 18LP REG 10 0 VC DS BO 44 HS REG HSSFCL 24CPSF 1B 1H 5 PG 20 5 8 SF 18 EM AC 18 CPC 2 SPC EH RSTPB 18LP REG 10 0 VC DS BO 42 HS REG HSSFCL 30CPSF 1B 1H 5 PG 25 5 8 SF 22 EM AC 18 CPC 2 SPC EH RSTPB 18LP REG 10 0 VC DS BO 40 HS REG HSS...

Page 5: ...lve Once the final positioning is established mark the burner and grate position of the floor of the fireplace for reference points Remove the grate and proceed with the gas connection See Figure 6 GAS CONNECTION Fig 3 1 The gas supply line should be 1 2 Inside Diameter ID up to 30 feet and 3 4 for longer distance 2 Use the aluminum connector AC 18 to connect the gas supply to the regulator on the...

Page 6: ...e glow PILOT FLAME Fig 5 1 The pilot light should be checked periodically to assure proper flame On the System 4 burner the flame should be on the right hand side of the burner pan See Figure 4 When turning the main burner on the pilot flame should ignite the main gas within 4 seconds without creating a big poof depending on the gas pressure GRATE PLACEMENT Fig 6 1 Place the Pedestal Grate over th...

Page 7: ...been underwater LIGHTING INSTRUCTIONS GAS OUTLET GAS INLET Pilot Adjustment Screw Pilot Gas Supply 4 Find pilot follow metal tube from the gas control behind the burner pan Pilot Burner Thermocouple 1 STOP Read the safety information above on this label 2 Push in gas control knob slightly and turn clockwise to OFF CONTROL KNOB NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in s...

Page 8: ...o turn the knob counterclockwise toward the FULL ON position until desired flame height is reached IMPORTANT GAS WILL NOT FLOW TO THE EMBER BURNER UNTIL THE LATCHTAP CLC BLOCK IS ENGAGED USING ON OF THE SWITCHING DEVICES REMOTE CONTROL BARK CHIP SWITCH OR WALL SWITCH FOR YOUR SAFETY WARNING If you do not follow these instructions exactly a fire or explosion may occur resulting in property damage p...

Page 9: ...tes do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you 3 HARGROVE MANUFACTURING CORPORATION WILL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL SPECIAL OR CONTINGENT DAMAGES YOU MIGHT SUFFER AS A RESULT OF A CLAIM UNDER THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY Some states do not allow the exclusion or limitation of incidental or consequent...