background image

 

 

 

USER’S MANUAL 

SEARCHLIGHTS SH R50 BUS 

 
 
 

 

 

 

 

 

 

7SL2001001  ;  Rev02 
DCN: 22877  ; 22.05.2018 

Summary of Contents for 7070404023366

Page 1: ...USER S MANUAL SEARCHLIGHTS SH R50 BUS 7SL2001001 Rev02 DCN 22877 22 05 2018 ...

Page 2: ...Therefore if you have any technical or other questions Norselight would be pleased to assist Our Technical Department can be contacted as follows Tel 47 69 17 99 99 Fax 47 69 17 99 89 E mail office norselight no We would also like to use this opportunity to thank you for choosing Norselight as your supplier of marine searchlights Guaranty The guarantee is only valid against production faults It do...

Page 3: ...NG SOLUTIONS 3 This manual belongs to the product Serie no ______________ Controlled by ______________ Date ______________ Technical Manual for searchlight SH 260 R50 SH 310 R50 SH 470 R50 SH 480 R50 250W 500W 1000W 2000W 3000W 24V DC 115V AC 230V AC ...

Page 4: ...3 Installation 15 Mechanical installation 15 Electric installation 15 BUS installation 15 Start up procedure 15 4 Operation 15 Operation Panels function 15 Change of lamp 16 General Searchlight Maintenance 17 5 Spare Parts list 18 6 Drawings 22 Mechanical Dimensions SH 260 to 470 R50 22 Mechanical Dimensions SH 480 R50 24 Pedestal R50 25 Operation Panel Main and Slave w cut dimensions 26 Switch BU...

Page 5: ...ntrol panels Main Operation Panel It contains the following functions Ready for max 2 Slave Operation Panels option BUS communication Lamp ON OFF Joystick for sweep and tilt horizontal and vertical movement Speed regulator for sweep and tilt Focus light beam adjustment LED Indication for searchlight position 360o Searchlight ID number End position function Designed for console or bulkhead mounting...

Page 6: ...6500201 Rev SH R50 6 Main and Slave Operation Panel ...

Page 7: ...6500201 Rev SH R50 7 180 135 90 45 Selection Searchlight ON LAMP Focus Horz Speed Searchlight Norway Wireless Operation Panel ...

Page 8: ...stem is connected to the same network through LAN switch to connect to a network of searchlights Control panels both hard wired and wireless are fitted into a standard solution Features and Benefits Wireless receiver for SCS wireless Bus Bolt on to Norselight s network of searchlights Die Cast Aluminium Compact and new design Based on TCP IP technology Waterproof quick disconnect RJ 45 connector C...

Page 9: ...ol Panel indicates the position of the searchlight 0o position on the panel indicates that the searchlight is positioned straight forward compared to the searchlight 0o position The searchlight has an 180o movement to the left and right end position in total 360 o To calibrate the position indicator you simply use the joystick on the Main Control Panel to turn the searchlight to end stop to both l...

Page 10: ...8A 8 7A 4 3A 17 4A 8 7A 26 1A 13A Lifetime appr 300h 750h 400h Luminous flux 6400 lm 12000 lm 27 500 lm 52 000 lm 82 000 lm Focal distance 50 8 mm 2 88 9mm 120 6 mm 127 mm Divergence 7 6 5 8o 11 10 8 8 Range at 1 lux 2454 m 2063 m 1540 m 2366 m 2100 m Parabolic silver plated glass reflector dia 10 1 4 260mm dia 12 305mm dia 18 457mm Drum and motor housing material Seawater resistant aluminium 5052...

Page 11: ... Panel Standard IEC 60945 Ed4 2002 08 Number of panels Standard max 2 pcs to each Main Operation Panel Network Direct connection to Main Operation Panel Interface Phoenix he she connector 3 81 pitch Cable 5 wire shielded connected 1 to 1 Power Requirements N A Physical Characteristics Casing IP22 protection Dimensions WxHxD 96x96x25 mm 3 78x3 78x0 98 in Weight 100g 0 22 pound Installation Table mo...

Page 12: ...bps 87 dBm 11Mbps 82 dBm Antenna Connector 1 x RP SMA Power Requirements Battery 4 8V 4 celle s 1650mAh NiMh Charger 230 VAC 70 150mAh 3 10 celle s NiCd NimH Physical Characteristics Casing IP65 protection Dimensions WxHxD 117x228x46 24 mm 4 6x8 97x1 82 in Weight 500g 1 1 pound Environmental Limits Operating Temperature 25 to 70 C 13 to 158 F Ambient Relative Humidity 0 to 95 non condensing Compas...

Page 13: ... 220VDC AC Power consumption 3 5W Physical Characteristics Casing IP40 protection Fanless design Dimensions WxHxD 36 5x120x90 mm 1 44x4 72x3 54 in Weight 300g 0 66 pound Installation DIN Rail or wall mounting Environmental Limits Operating Temperature 40 to 85 C 40 to 185 F Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 0 to 95 non condensing Approvals IEC61000 4 2 ESD 8KV co...

Page 14: ...s 1600m RADIO OPERATING Frequency 2412 2464 MHz TX Power 15dBm 20dBm EIRP including Antenna RX Sensitivity 90dBm 11Mbps ANTENNA SPECIFICATION Gain 5dBi Omni directional Frequencey 2400 2485 MHz Vertical horizontal BW 25x360 degree Weight 0 5Ibs 0 2Kg Dimension 355x15mm PHYSICAL ELECTRICAL ENVIRONMETNAL Enclosure Size 185x130x50mm Mounting Supports masts up to 3 diameter Weight 1 50kg Enclosure Cha...

Page 15: ... shielded twisted pair cable All connection entries need RJ45 connector using T 568B cable standard Make sure that all cable entries maintain their shield protection Note Follow the installation requirements from your cable supplier Avoid brakeage on the Ethernet connectors panel switch and searchlight COM module Start up procedure Powering up By powering up the SCS R50 Searchlight system the pane...

Page 16: ...sts the motor speed vertically in the range from 1 to 15 indicated in LED display Horizontal speed Adjusts the motor speed horizontally in the range from 1 to 15 indicated in LED display Lamp LAMP Lamp on off function Green LED for lamp ON Dim Adjusts the intensity of the backlight in the panel indicated in LED indication display Joystick Searchlight direction Horizontal Vertical Allow the searchl...

Page 17: ...the bulb with bare hands or anything greasy Be careful not to damaged any parts If the bulb is dirty the quartz surfaces should be cleaned with a soft cloth soaked in spirit Do not scratch the bulb or place it where it can be in touch with water as there is a danger that it will explode General Searchlight Maintenance Performed at intervals not exceeding 6 months Control of all gaskets and cable g...

Page 18: ...p Holder Complete w focus 24V 500W N A 1009195 N A N A 4 Lamp Holder Complete w focus 115V 1000W N A OR OR N A 4 Lamp Holder Complete w focus 230V 1000W N A OR 1009181 N A 4 Lamp Holder Complete w focus 115V 2000W N A N A 1009130 N A 4 Lamp Holder Complete w focus 230V 2000W N A N A 1009109 N A 4 Lamp Holder Complete w focus 230V 3000W N A N A N A 1009194 5 Focus unit Complete 1009148 6 Drum compl...

Page 19: ... 230V 1009288 21 Motor Hor Vert 1009224 22 Heat Element Gear 24V 115V 230V 1009234 1009233 1009232 23 MDC complete 1009377 24 Powermodule R50 complete 24V OR OR N A N A 24 Powermodule R50 complete115 230V N A OR OR OR 25 Seal KIT Motor house 1009375 26 Motorhouse complete OR OR OR OR 27 Power supply motor house 115 230V 3009009 ...

Page 20: ...6500201 Rev SH R50 20 Spare Parts SH 260 470 R50 BUS ...

Page 21: ...6500201 Rev SH R50 21 Spare Parts SH 480 R50 BUS ...

Page 22: ...6500201 Rev SH R50 22 Drawings Mechanical Dimensions SH 260 to 470 R50 ...

Page 23: ...6500201 Rev SH R50 23 ...

Page 24: ...6500201 Rev SH R50 24 Mechanical Dimensions SH 480 R50 ...

Page 25: ...6500201 Rev SH R50 25 Pedestal R50 ...

Page 26: ...6500201 Rev SH R50 26 Operation Panel Main and Slave w cut dimensions ...

Page 27: ...plug KEIN1005S 5T or 1 one full duplex fiber port of 100Base FX single mode or multimode and 4 LAN cable entries KEIN1005 1S M 4T Look in the manual for KEIN1005 for more details Installation DIN 35 Rail or wall mounting Power in Plug incl connector Fiber Optic LAN RJ45 connection ...

Page 28: ...6500201 Rev SH R50 28 Ethernet BUS LAN Cables only ...

Page 29: ...6500201 Rev SH R50 29 ...

Page 30: ...6500201 Rev SH R50 30 ...

Page 31: ...6500201 Rev SH R50 31 Electrical installation SH 260 and 310 24V DC ...

Page 32: ...6500201 Rev SH R50 32 Electrical installation SH 310 to 480 115 230V AC ...

Page 33: ...6500201 Rev SH R50 33 Halogen Cable oveview ...

Page 34: ...6500201 Rev SH R50 34 Junction box connection 24V Junction box connection 115 V 230V Cable 2 LAN Cable 3 Power Ground connection and Cable 2 LAN Cable 3 Power Ground connection L1 and L2 ...

Page 35: ...O connecting adapter to RJ45 with termination points up to 1 5mm2 or WAGO connecting plug RJ45 WAGO connecting adapter Item no 289 175 Product description INTERFACE MODUL FOR ETHERNET RJ 45 CAGE CLAMP CONNECTION for DIN 35 rail Or Phoenix Connectors RJ45 connector Item no 1658435 IP20 CAT5e 4 pos PROFINET with QUICKON fast connection technology for 1 wire and 7 wire conductors AWG 26 22 for cable ...

Page 36: ...6500201 Rev SH R50 36 Connecting diagram Main and Slave Operation Panel ...

Page 37: ...6500201 Rev SH R50 Internal wire diagram SH 260 and 310 R50 24V DC ...

Page 38: ...6500201 Rev SH R50 SH 310 to 480 115 230V AC ...

Page 39: ...be pleased to help you when ordering spare parts for maintenance and repair works as well as in case of problems and questions Manufacturer Glamox Production GmbH Co KG Glasower Weg 5 17166 Teterow Germany Service contact Glamox Production GmbH Co KG Tel 49 421 48 93 0 E Mail info aquasignal de Internet www glamox com gmo ...

Page 40: ...6500201 Rev SH R50 7 Owner s NOTES ...

Reviews: