background image

NEXCOM International Co., Ltd.

NEXCOM International Co., Ltd.

Published September 2016

www.nexcom.com

Interactive Signage Platform

Digital Signage Platform 
NDiS B425-SI3

User Manual

Summary of Contents for NDiS B425-SI3

Page 1: ...NEXCOM International Co Ltd NEXCOM International Co Ltd Published September 2016 www nexcom com Interactive Signage Platform Digital Signage Platform NDiS B425 SI3 User Manual ...

Page 2: ...troduction NDiS B425 SI3 1 Overview 1 Key Features 1 Hardware Specifications 2 Knowing Your NDiS B425 SI3 3 Front Panel 3 Rear Panel 4 Mechanical Dimensions 5 Chapter 2 Jumpers and Connectors Before You Begin 6 Precautions 6 Jumper Settings 7 Location of the Jumpers and Connectors 8 Top View 8 Bottom View 9 Connector Button Table 10 Header Wafer Table 10 Chapter 3 System Setup Installing a SATA HD...

Page 3: ...Copyright 2016 NEXCOM International Co Ltd All Rights Reserved iii NDiS B425 SI3 User Manual Content Power 28 Security 30 Boot 30 Save Exit 32 Appendix A Watchdog 33 ...

Page 4: ... of NEXCOM International Co Ltd All other product names mentioned herein are registered trademarks of their respective owners Regulatory Compliance Statements This section provides the FCC compliance statement for Class A devices and describes how to keep the system CE compliant Declaration of Conformity FCC This equipment has been tested and verified to comply with the limits for a Class A digita...

Page 5: ... and Polybrominated diphenyl Ethers PBDE 0 1 or 1 000ppm In order to meet the RoHS compliant directives NEXCOM has established an engineering and manufacturing task force to implement the introduction of green products The task force will ensure that we follow the standard NEXCOM development procedure and that all the new RoHS components and new manufacturing processes maintain the highest industr...

Page 6: ...defective products making sure it is durable enough to be resistant against further damage and deterioration during transportation In case of damages occurred during transportation the repair is treated as Out of Warranty Any products returned by NEXCOM to other locations besides the customers site will bear an extra charge and will be billed to the customer Repair Service Charges for Out of Warra...

Page 7: ...s and power supply are inconsistent with these instructions or the instructions for accessory modules contact the supplier to find out how you can ensure that your computer meets safety and regulatory requirements Cautions Electrostatic discharge ESD can damage system components Do the described procedures only at an ESD workstation If no such station is available you can provide some ESD protecti...

Page 8: ...age the soft metal or plastic parts of the connectors Safety Information Before installing and using the device note the following precautions Read all instructions carefully Do not place the unit on an unstable surface cart or stand Follow all warnings and cautions in this manual When replacing parts ensure that your service technician uses parts specified by the manufacturer Avoid using the syst...

Page 9: ... the voltage and current rating marked on the product 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened ...

Page 10: ...ation of the installed software operating system version application software etc A complete description of the problem The exact wordings of the error messages Warning 1 Handling the unit carry the unit with both hands and handle it with care 2 Maintenance to keep the unit clean use only approved cleaning products or clean with a dry cloth Conventions Used in this Manual Warning Information about...

Page 11: ...o 920 Chung Cheng Rd ZhongHe District New Taipei City 23586 Taiwan R O C Tel 886 2 8226 7796 Fax 886 2 8226 7792 Email sales nexcom com tw www nexcom com tw NEXCOM Intelligent Systems Taichung Office 16F No 250 Sec 2 Chongde Rd Beitun Dist Taichung City 406 R O C Tel 886 4 2249 1179 Fax 886 4 2249 1172 Email sales nexcom com tw www nexcom com tw Japan NEXCOM Japan 9F Tamachi Hara Bldg 4 11 5 Shiba...

Page 12: ...comitalia it NEXCOM Shanghai Room 603 604 Huiyinmingzun Plaza Bldg 1 No 609 Yunlin East Rd Shanghai 200333 China Tel 86 21 5278 5868 Fax 86 21 3251 6358 Email sales nexcom cn www nexcom cn NEXCOM Surveillance Technology Room 209 Floor 2 East No 2 Science Technology industrial park of privately owned enterprises Xili Nanshan Dist Shenzhen 518055 China Tel 86 755 8364 7768 Fax 86 755 8364 7738 Email...

Page 13: ...I3 User Manual Preface Package Contents Before continuing verify that the NDiS B425 SI3 package that you received is complete Your package should have all the items listed in the following table Item Name Qty 1 Power adapter 1 2 Wall Mount 1 3 Driver DVD 1 Power Adapter Wall Mount ...

Page 14: ... All Rights Reserved xiv NDiS B425 SI3 User Manual Preface Ordering Information The following below provides ordering information for NDiS B425 SI3 Barebone NDiS B425 P N 10W00B42501X0 6th generation Intel Core i3 6100U Dual Core fanless system ...

Page 15: ...5 SI3 Overview NDiS B425 BI3 comes with a compact fanless design and is powered by 6th generation Intel Core i3 6100U SoC processor integrated with Intel HD520 Graphics controller can handle very rich multimedia contents NDiS B425 BI3 supports display output by HDMI and Mini DP ports it can offer impressive system performance and 4Kx2K videos The NDiS B425 BI3 signage player can fully satisfy cust...

Page 16: ...terface Rear 19V DC in 1x HDMI 1x Mini DisplayPort 1x DB9 for RS 232 2x USB 3 0 1x RJ45 with LED for 10 100 1000Mbs Ethernet Storage 1x 2 5 HDD SSD Dimensions 167mm W x 139 6mm D x 55mm H w o mounting bracket Construction Top cover made by aluminum for main heat exchange Power Supply 1x External 65W AC DC adapter Input 100 240VAC Output 19V Expansion 1 x NGFF M 2 E key for optional 2230 WLAN modul...

Page 17: ...he 2 external antenna mounting holes are used to mount and connect optional Wi Fi GPS GSM antennas Power Switch Power LED Power switch with power status LED indicator Press to power on or power off the system USB 3 0 Ports Used to connect USB 3 0 2 0 1 1 devices Headset Mic Combo Jack Used to connect a headphone or microphone Antenna Hole Antenna Hole Power Switch Power LED Headset Mic USB 3 0 ...

Page 18: ...ug a DC power cord HDMI Port Used to connect an HDMI interface monitor Mini DisplayPort Used to connect a Mini DisplayPort interface monitor USB 3 0 Ports Used to connect USB 3 0 2 0 1 1 devices LAN Port Used to connect the system to a local area network COM Port The COM port supports RS232 compatible serial devices COM MiniDP HDMI LAN USB 3 0 19V DC Input ...

Page 19: ...Copyright 2016 NEXCOM International Co Ltd All Rights Reserved 5 NDiS B425 SI3 User Manual Chapter 1 Product Introduction Mechanical Dimensions 167 139 60 210 70 164 70 55 65 ...

Page 20: ...lf before touching any internal components by touching a metal object Static electricity can damage many of the electronic components Humid environments tend to have less static electricity than dry environments A grounding strap is warranted whenever danger of static electricity exists Precautions Computer components and electronic circuit boards can be damaged by discharges of static electricity...

Page 21: ...the jumpers ensure that the jumper caps are placed on the correct pins When the jumper cap is placed on both pins the jumper is short If you remove the jumper cap or place the jumper cap on just one pin the jumper is open Refer to the illustrations below for examples of what the 2 pin and 3 pin jumpers look like when they are short on and open off Two Pin Jumpers Open Left and Short Right Three Pi...

Page 22: ... International Co Ltd All Rights Reserved 8 NDiS B425 SI3 User Manual Chapter 2 Jumpers and Connectors SW1 J156 J151 J78 XBT1 J158 J63 P111 DIMM 2 DIMM 1 J8 J138 J125 J124 PJ1 Location of the Jumpers and Connectors Top View ...

Page 23: ...Copyright 2016 NEXCOM International Co Ltd All Rights Reserved 9 NDiS B425 SI3 User Manual Chapter 2 Jumpers and Connectors P118 J12 P70 Bottom View ...

Page 24: ...tor J63 NGFF M 2 E Key Connector For 2230 J158 NGFF M 2 M Key Connector For 2242 J156 USB 3 0 Connector J151 USB 3 0 Connector J78 Headset Microphone Phone Jack J8 RJ45 GbE LAN Connector J138 Dual USB 3 0 Connector J125 Mini DisplayPort Connector J124 HDMI Connector PJ1 DC 19V Power in Connector Connector Name P70 Power LED J12 USB Pin Header P118 Debug Wafer XBT1 RTC Battery Wafer Connector Butto...

Page 25: ...m Setup Chapter 3 System Setup Installing a SATA HDD Prior to removing the chassis cover make sure the unit s power is off and disconnected from the power sources to prevent electric shock or system damage CAUTION CAUTION CAUTION 1 Remove the mounting screws around the chassis cover and then remove the cover ...

Page 26: ... Setup 2 Align the mounting holes that are on the sides of the SATA drive with the mounting holes on the drive bay and then use the provided mounting screws to secure the drive in place 3 Place the SATA drive in the chassis and connect the SATA data connector then use screws to secure the drive in the chassis ...

Page 27: ...s of the socket lock into position You will hear a distinctive click sound indicating the module is correctly locked into position 1 Insert the module into the socket at an approximately 30 degrees angle Apply firm even pressure to each end of the module until it slips into the socket The gold plated connector on the edge of the module will almost completely disappear inside the socket Memory modu...

Page 28: ...e NGFF M 2 Wi Fi module package includes the following items NGFF M 2 Wi Fi Module Antennas RF Cables Installing a NGFF M 2 Wi Fi Module Optional 2 Insert the NGFF M 2 Wi Fi Module into the NGFF M 2 slot at a 45 degrees angle until the gold plated connector on the edge of the module completely disappears inside the slot ...

Page 29: ... NEXCOM International Co Ltd All Rights Reserved 15 NDiS B425 SI3 User Manual Chapter 3 System Setup 3 Secure the module with mounting screws 4 Attach one end of the RF cables onto the module Mounting screw RF cable ...

Page 30: ...s Reserved 16 NDiS B425 SI3 User Manual Chapter 3 System Setup 5 Insert the antenna jack end of the cable through the antenna hole Antenna jack end of the cable 6 Insert ring 1 and ring 2 onto the antenna jack end of the cable Ring 1 Ring 2 Antenna jack ...

Page 31: ...ghts Reserved 17 NDiS B425 SI3 User Manual Chapter 3 System Setup Installing Wall Mount Brackets 1 Align the mounting holes on the wall mount brackets to the mounting holes on both sides of the system then secure the brackets with screws Mounting hole ...

Page 32: ...User Manual Chapter 3 System Setup Installing the VESA Mount Kit 1 Align the mounting holes on the VESA mount kit to the VESA mounting holes on the back of the monitor then secure the VESA mount kit with screws 2 Secure the system to the VESA mount bracket with screws Mounting hole ...

Page 33: ...ystem is configured with the values found in CMOS With easy to use pull down menus you can configure such items as Hard drives diskette drives and peripherals Video display type and display options Password protection from unauthorized use Power management features The settings made in the setup program affect how the computer performs It is important therefore first to try to understand all the s...

Page 34: ...ll be reported in one of two different ways If the error occurs before the display device is initialized a series of beeps will be transmitted If the error occurs after the display device is initialized the screen will display the error message Powering on the computer and immediately pressing Del allows you to enter Setup Press the key to enter Setup Legends Key Function Moves the highlight left ...

Page 35: ...setup screen it indicates that there are more available fields not shown on the screen Use the up and down arrow keys to scroll through all the available fields Submenu When appears on the left of a particular field it indicates that a submenu which contains additional options are available for that field To display the submenu move the highlight to that field and press ...

Page 36: ...ral Help F7 Discard Changes F9 Optimized Defaults F10 Save Exit ESC Exit Set the Time Use Tab to switch between Time elements System Overview AMIEFI BIOS Version Build Date System Memory Size System Time System Date MAC Address Halt On SKLD4P1 NEXCOM 0303A 04 12 2016 4096 MB DDR4 18 45 57 Tue 04 26 2016 84 00 2D 20 7F D2 No Errors System Date The date format is day month date year Day displays a d...

Page 37: ...r Intel Intel R Celeron R CPU 3855U 1 60GHz Frequency 1 60 GHz Cache L1 32 KB x2 Cache L2 256 KB x2 Cache L3 2048 KB Ratio Actual Value 16 Virtualization Tech Disabled EIST tech Enabled Turbo Boost Tech Enabled CPU C6 report Enabled CPU C7 report Enabled Virtualization Tech When this field is set to Enabled the VMM can utilize the additional hardware capabilities provided by Vanderpool Technology ...

Page 38: ... storage devices SATA Controller Enables or disables the SATA controller SATA Mode Selection Configures the SATA as AHCI mode AHCI This option configures the Serial ATA drives to use AHCI Advanced Host Controller Interface AHCI allows the storage driver to enable the advanced Serial ATA features which will increase storage performance Advanced Version 2 17 1254 Copyright C 2016 American Megatrends...

Page 39: ...ct Fan fault Hardware Health Configuration CPU Fan Fail Warning Disabled CPU Q FAN Control Disabled CPU Temperature 35 C Tcontrol Offset 85 C CPU Fan Speed 5113 RPM VCore Voltage 1 188 V 3 3V Voltage 3 309 V 5V Voltage 5 044 V 12V Voltage 12 230 V CPU Fan Fail Warning Enables or disables detection of fan failure CPU Q FAN Control Enables or disables control of CPU fan speed CPU Temperature Detects...

Page 40: ...Onboard VGA Config Onboard Audio Onboard LAN Device LAN Boot ROM Serial Port 1 Configuration Device Settings Change Settings Serial Port 2 Configuration Device Settings HD Audio Enabled Enabled Enabled IO 3F8h IRQ 4 Auto Disabled Reset Required Onboard Device Settings This section is used to configure the onboard devices Onboard VGA Config Configuration for onboard VGA devices Onboard Audio Enable...

Page 41: ...016 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F7 Discard Changes F9 Optimized Defaults F10 Save Exit ESC Exit Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available Trusted Computing Settings TPM Supported Disabled Onboard VGA Config This section is used to con...

Page 42: ...figure Intel Management Engine Intel ME Power This section is used to configure the power management features APM Configuration Configuration for Advanced Power Management EUP Enables the system to shut down to the lowest possible power state by removing all power to the system board The wake up function will be lost if EUP is enabled Save Exit Advanced Power Security Boot Main Version 2 17 1254 C...

Page 43: ...em to wake up on LAN Power on RTC Alarm Enables or disables the system to wake up on RTC alarm When enabled the system will wake on the hr min sec specified RTC Alarm Date Hour Minute and Second Configures the date and time of the RTC alarm AC Power Loss Power Off When power returns after an AC power failure the system s power is off You must press the power button to power on the system Power On ...

Page 44: ...e Secure Boot Secure Boot only works when the system runs in user mode Secure Boot Mode Select this to configure the Secure Boot mode Standard Fixed secure boot policy Custom Changeable Image Execution policy and Secure Boot key databases Boot Launch CSM This option controls if CSM will be launched Boot Option Filter Configures which devices the system will boot from Network Drives Sets the order ...

Page 45: ... Security Boot Main Version 2 17 1254 Copyright C 2016 American Megatrends Inc Aptio Setup Utility Copyright C 2016 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F7 Discard Changes F9 Optimized Defaults F10 Save Exit ESC Exit Enable or Disable Full Screen Logo Boot Settings Configuration Full Screen Logo Bootup Num Lock Keyboard Error Message Display Fas...

Page 46: ... select this field then press Enter A dialog box will appear Confirm by selecting Yes You can also press F4 to save and exit Setup Discard Changes and Exit To exit the Setup utility without saving the changes select this field then press Enter You may be prompted to confirm again before exiting You can also press ESC to exit without saving the changes Load Optimal Defaults To restore the BIOS to d...

Page 47: ...ared 0 WDT Status 1 WDT value is equal to 0 0 WDT value is not equal to 0 SMI Control Register 2 Index F1h Default 00h Bit Description 7 Reserved 6 0 Edge trigger 1 Level trigger 5 3 Reserved 2 This bit is to enable the generation of a SMI due to WDT s IRQ EN_WDT 1 This bit is to enable the generation of a SMI due to CIR s IRQ EN_CIR 0 This bit is to enable the generation of a SMI due to PBD s IRQ...

Page 48: ...ct 1 62 5ms x WDT Timer out value default 3 5s 0 Determined by WDT Time out value select 1 bit 7 of this register 4 WDT Output through PWRGD Enable 1 Enable 0 Disable During LRESET this bit is selected by JP2 power on strapping option 3 0 Interrupt Level Select for WDT Please refer to Interrupt Level Mapping Table Watchdog Timer Time out Value LSB Register Index 73h Default 38h Bit Description 7 0...