background image

Man Pt No 701859 

Rev 3-01 

 

 

INSTALLATION and OPERATION MANUAL for GXD SERIES BREWERS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 

 
 
 

              GXDF2-30                                                                                            GXDF-8D 

 

 

 

BREWER SPECIFICATIONS 

 

Model 

No of 

Warmers 

 

Width 

 

Length 

 

Height* 

US 

120V 

Amps 

US 

120/240V 

Amps 

 

Phase 

GXDF2-15 2  19” 

19-1/8" 

21-3/8” 

13.5 24.9  Single 

GXDF2-30 2  19” 

19-1/8" 

26-5/8” 

14.0 25.4  Single 

GXDF-8D N/A 19” 

19-1/8" 

30-3/4” 11.5 22.9  Single 

GXDF-8D N/A 19” 

19-1/8" 

30-3/4” N/A  25.3 

Three 

(delta) 

 

 

 

 

 

 

 

 

Shipping weight is approximately 65 pounds for all above units 

* Height does not include the 4” adjustable legs. Add approximately 4” to the height shown when using these legs. 
 
NOTE: Automatic models without faucet are also available. 

Summary of Contents for GXDF-8D

Page 1: ...15 2 19 19 1 8 21 3 8 13 5 24 9 Single GXDF2 30 2 19 19 1 8 26 5 8 14 0 25 4 Single GXDF 8D N A 19 19 1 8 30 3 4 11 5 22 9 Single GXDF 8D N A 19 19 1 8 30 3 4 N A 25 3 Three delta Shipping weight is approximately 65 pounds for all above units Height does not include the 4 adjustable legs Add approximately 4 to the height shown when using these legs NOTE Automatic models without faucet are also ava...

Page 2: ...trol center to alert the user that a brew cycle has either been initiated or is in process and to use caution This feature also has a calibration adjustment on the control board which allows for the calibration to continue the light flashing until the coffee completely drains from the brew basket Note A new brew cycle will not be accepted until the Visa Light stops flashing This design eliminates ...

Page 3: ...her a 120 240V ac single phase circuit or a 120 240V ac three phase delta circuit Refer to the brewer name plate on back of brewer The pictorial view at the bottom of this page illustrates the power cord connection to the terminal block for both circuits A wiring diagram at the rear of this manual illustrates the complete brewer wiring Note that the tank heater system is the only portion of the br...

Page 4: ... position momentarily until the fill cycle begins and then turned back When the tank reaches the preset temperature the fill portion of the brew cycle will begin The tank lid must be in place for proper unit operation When water begins to flow from brew basket the brew cycle may be canceled by depressing the brew start stop switch Allow water to finish draining from the unit and then empty the con...

Page 5: ... at the start of the brew cycle and when the decanter is half full Recommended temperature of the water is approximately 195 F Note Brew cycle may be canceled by depressing the brew start stop switch The brewer features an electronic temperature control circuit and the temperature may be adjusted with the control board located behind the right side access plate See Figure below for control board s...

Page 6: ...should continue to flash until all the liquid has finished flowing from the brew basket Do not remove decanter until the brewing process has stopped and all liquid has stopped flowing from the brewbasket 10 The resultant coffee brew should be crystal clear and have the desired properties attainable through excellent extraction 11 To clean brew basket simply remove from brew rails and dump filter i...

Page 7: ...7 FACE PLATE DIAGRAM MODEL GXDF 8D WIRING DIAGRAM Newco Enterprises Inc 1735 South River Rd P O Box 852 St Charles MO 63303 ...

Reviews: