Page 3: ...trol SQL Option Ver2 1 3 The term iSM in this text refers to all the NEC Storage Manager program products 4 The term Microsoft SQL Server 2000 in this text refers to either Microsoft SQL Server 2000 Enterprise Edition or the Microsoft SQL Server 2000 Standard Edition 5 Trademarks and registered trademarks HP UX is a registered trademark of Hewlett Packard Co in the United States UNIX is a register...

Page 4: ......

Page 5: ...1 1 1 Message Classification 2 1 2 Message Output Destinations 3 1 3 Message Output Format 5 Chapter 2 Message List 6 2 1 Interpretation of Message List 6 2 2 Message List 7 Appendix A Message Output Destination List 414 Appendix B Changed Message List 440 ...

Page 6: ...onControl outputs the operation information of data replication in a message format to the log files of the console terminal and the business server The message is output to syslog event log and operation log The message describes the information for checking operating conditions such as command execution results and fault and error detection information etc Figure 1 1 shows an overview of message...

Page 7: ...by an administrator is required An administrator must troubleshoot and recover the system promptly WARNING Warning message This message indicates an event that requires attention regarding the system operations though the event does not necessarily lead to the system down immediately An administrator must remove the cause of the event and take measures to operate the system normally NOTICE Notifyi...

Page 8: ...Manager or the NEC Storage ReplicationControl a message indicating execution result is displayed on the console or the terminal where the command is executed Operation log Operation log which is output on UNIX and Windows records the messages output from the NEC Storage Manager or the NEC Storage ReplicationControl only During the operation of iSM client the information output to the operation log...

Page 9: ... is not output as the default value To output these kinds of messages modify the OS settings file Note 2 The function of messages output from the NEC Storage Manager to syslog is Daemon However the function of the messages output by the NEC Storage ReplicationControl command is user Messages are output being affixed the following directory file name as the default value HP UX system var adm syslog...

Page 10: ...sification cccccccc Command name and function name yyyyy Message number The message which is output to application log in the event log includes the following values specified for each item Classification ERROR Error WARNING Warning NOTICE Information INFO Information Source NEC Storage Manager fixed Classification None fixed Event ID Number part in the message ID output to the operation log The f...

Page 11: ...on Classification Message classification ERROR WARNING NOTICE or INFO is described A message that is not output to syslog event log or operation log is output without a message classification This field is blank for such a message that is output without a message classification Explanation This field describes the causes of the message output etc Parameters in the message are also described in thi...

Page 12: ...lanation It shows that iSM server has started Measures Unnecessary iSM01002 NEC Storage Manager is ready Classification INFO Explanation It shows that iSM server has become capable of operation Measures Unnecessary iSM01003 NEC Storage Manager has terminated normally Classification INFO Explanation It shows that iSM server has normally terminated Measures Unnecessary ...

Page 13: ... system is shut down This message is output on UNIX system Measures Unnecessary iSM01005 Command is entered command aaa a Classification INFO Explanation It shows that a command is entered This message is output on UNIX system aaa a command that is entered Measures Unnecessary iSM01006 Termination of NEC Storage Manager is started Classification WARNING Explanation It shows that abort processing o...

Page 14: ...n WARNING Explanation The function indicated with aaa a has become unavailable iSM server will block the function aaa a Unavailable function PerformanceMonitor Performance monitoring function ReplicationControl Replication control function msgdrv Message drive config GUI Configuration setting GUI function PerformanceOptimizer Performance optimization function iSMcmd Configuration setting GUI funct...

Page 15: ...b errno ccc error ddd d detail ee fff Classification NOTICE Explanation Error has occurred in the socket communication between the processes indicated with aaa a and the main process This error occurs when the process has stopped or the file environment of iSM Serve s socket path opt iSMsvr etc sock is in an incorrect status aaa a Process name bbb b Socket system function name ccc Error number ddd...

Page 16: ...function name and error number and restart iSM server iSM01106 System call error occurred process aaa a func bbb b errno ccc detail dd eee Classification NOTICE Explanation It shows that an error has occurred in the system function except the access of socket file The Following hindrance is likely as an example In case of syslog The shared memory has been deleted incorrectly with the ipcrm command...

Page 17: ...as already started Classification NOTICE Explanation It shows that the iSM server has already started This message is output on UNIX system Measures Unnecessary iSM01109 Internal error occurred detail aa bbb Classification WARNING Explanation It shows that an internal error has occurred in the main process of iSM server iSM server will be terminated aa bbb Detail code This code isn t disorder reas...

Page 18: ...tion was found eee e Parameter value or words wherein illegal configuration was found fff f Words wherein illegal configuration was found Measures Find out incorrect description in the file through the output message correct it and then restart iSM server iSM01111 User definition does not exist Client cannot be connected file aaa a Classification NOTICE Explanation It shows that there is no specif...

Page 19: ...or words wherein illegal configuration was found eee e Parameter value or words wherein illegal configuration was found Measures Restart the iSM server with Super User to receive SNMP trap while the iSM server uses the port 162 If the iSM server does not use the port 162 for receiving SNMP trap restart the iSM server after deleting the parameter for snmp_port 0 iSM01230 NEC Storage Manager has ter...

Page 20: ...e has been specified by iSMsvr command This message is output on UNIX system Measures Check command format and retry iSM01401 Usage iSMsvr start Explanation It indicates that description of iSMsvr start command is incorrect A specifiable format is shown in the message Execute the command in valid format This message is output on UNIX system Measures Check command format and retry iSM01402 Usage iS...

Page 21: ...dicates that a command was not accepted because the NEC Storage Manager is not operative Measures Retry command execution when the NEC Storage Manager becomes operative iSM01408 Rejected System function error aaa a bbb b Explanation It indicates that an error occurred in a system function indicated by aaa aaa a System function name bbb b Error description errno zzzz Error number socket close Socke...

Page 22: ...tes that a device monitoring stop restart command request has been received For actual stop restart operations refer to syslog This message is output on UNIX system Measures Unnecessary iSM01411 Rejected PerformanceMonitor is not available Explanation It indicates that the performance monitor function is not available Measures Unnecessary iSM01412 Internal error detail aaaa Explanation It indicate...

Page 23: ...system Measures Check command format and retry iSM01901 Function error has occurred Function name aaa a Error code bbb Error Message ccc c Classification ERROR Explanation It is an internal error of iSMmainNT This seems to be a problem depending on Windows system This message is output on Windows system aaa a Function name bbb Error number ccc c Error message Measures Resolve the problem by checki...

Page 24: ...r of 8020 at the time of an abbreviation is being used in other service or if the specified port number is correct To check the port number being used use netstat command For Windows Check the server operation environment and review the port number settings iSM02011 In initialization shared memory allocation failed errno aaaaa Classification NOTICE Explanation It shows that the acquisition of shar...

Page 25: ...e socket has been disconnected from a client iSM02021 Internal Error has occurred code aaaaa errno bbbbb Classification NOTICE Explanation It shows that an internal error has occurred This message is output on UNIX system aaaaa Internal code bbbbb Error number Measures Check the connection status of iSM client the environment of server operation and various settings This message is usually output ...

Page 26: ...FO Explanation It shows that an iSM client has exited aaa a User name bbbbbbbb iSM client name ccc c iSM client s IP address Measures Unnecessary This message indicates that the operation is completed as required iSM02042 iSM Client disconnected user aaa a client bbbbbbbb ip ccc c reason ddd Classification NOTICE Explanation It shows that iSM client has been disconnected aaa a User name bbbbbbbb i...

Page 27: ...dress 004 Excessive connection of clients 005 Resource shortage 006 Reconnection demand during the process of disconnection of the client 007 Start terminating iSM server 008 Internal error generated 009 Others 010 Time out generated in the iSM server Measures Resolve the problem from the reason of disconnection and reconnect the client iSM02050 iSM Client Management Service started Classification...

Page 28: ...tion of iSM Client Management Service has started Measures Unnecessary This message indicates that the operation is completed as required iSM02053 iSM Client Management Service is waiting for L3 user s termination Classification INFO Explanation It shows that iSM Client Management Service is waiting for the termination of L3 user This message is output on UNIX system Measures iSM server has become...

Page 29: ... In this case the response to operation demand from iSM client may possibly be lost and the information display in the iSM client may not be shown completely iSM02061 Data lost recovered client aaaaaaaa ip bbb b Classification NOTICE Explanation It shows that the received and transmitted data lost during process has been recovered This message is output on UNIX system Output only to syslog aaaaaaa...

Page 30: ...onment settings disk array information If no problem is found check disk connection environment and restart iSM server iSM03101 Object Disk Array does not exist detail aa bbbb Classification WARNING Explanation It shows that the iSM server is started with no disk arrays to be controlled because no disk arrays to be controlled are found aa bbbb Detail information This code isn t disorder reason but...

Page 31: ...efinition file correctly and restart iSM server On Windows system correctly specify diskarray a and diskarray b in environment settings specifying disk array information and restart iSM server iSM03103 IP address aaa a in diskarray b is invalid description detail cc dddd Classification ERROR Explanation IP address specified by diskarray b is incorrect The iSM server terminates abnormally aaa a IP ...

Page 32: ...art iSM server On Windows system correctly specify diskarray b in environment settings specifying disk array information and restart iSM server iSM03105 IP address aaa a in diskarray b is defined the other specification detail cc dddd Classification ERROR Explanation IP address specified by diskarray b is overlapping with others The iSM server terminates abnormally aaa a IP address b Disk array sp...

Page 33: ...orrectly and restart iSM server On Windows system correctly specify diskarray b and diskarray c in environment settings specifying disk array information and restart iSM server iSM03107 IP address aaa a in diskarray b contradicts the other specification detail cc dddd Classification ERROR Explanation The IP addresses specified in diskarray b indicates different disk arrays iSM server terminates ab...

Page 34: ... environment settings specifying disk array information and restart iSM server iSM03108 Disk disk aaa Port bbb Bus ccc Target ddd Lun eee in diskarray f is invalid description detail gg hhhh Classification ERROR Explanation The disk specified for diskarray i in the environment definition file agent section is erroneous The disk may be nonexistent The iSM server terminates abnormally This message i...

Page 35: ...pecifying disk array information and restart iSM server iSM03109 Disk disk aaa Port bbb Bus ccc Target ddd Lun eee in diskarray f is not control path to the management object detail gg hhhh Classification ERROR Explanation A disk specified by environment setting setting of disk array is not a control path for the monitoring target disk array The iSM server terminates abnormally This message is out...

Page 36: ...ment settings specifying disk array information and restart iSM server iSM03110 Disk disk aaa Port bbb Bus ccc Target ddd Lun eee in diskarray f is defined in the other specification detail gg hhhh Classification ERROR Explanation Disks specified in environment setting setting of disk arrays overlap with each other The iSM server terminates abnormally This message is output on Windows system diska...

Page 37: ...nvironment settings specifying disk array information and restart iSM server iSM03111 Disk disk aaa Port bbb Bus ccc Target ddd Lun eee in diskarray f is same as one in diskarray g detail hh iiii Classification ERROR Explanation The same disk is specified in diskarray f and diskarray g The iSM server terminates abnormally This message is output on Windows system diskaaa Portbbb Busccc Targetddd Lu...

Page 38: ...settings specifying disk array information and restart iSM server iSM03112 Disk disk aaa Port bbb Bus ccc Target ddd Lun eee in diskarray f contradicts the other specification detail gg hhhh Classification ERROR Explanation The disks specified in disk array in environment definition indicate different disk arrays The iSM server terminates abnormally This message is output on Windows system diskaaa...

Page 39: ...find detail bb cccc Classification WARNING Explanation The diskarray a has already been incorporated by automatic detecting function This message is displayed when incorporating by an IP address specified by diskarray a failed upon iSM server startup and the disk array has been incorporated by the automatic detection function Access to the disk array is not made via the IP address Ethernet specifi...

Page 40: ...ntenance Measures Unnecessary iSM03121 Management of diskarray a failed detail bb cccc Classification WARNING Explanation Succeeded in incorporating disk array specified by agent section diskarray a in environment definition file On Windows system the message indicates that the disk array specified by environment setting setting of disk array information diskarray a was successfully incorporated T...

Page 41: ...sary iSM03130 Management of control path in diskarray a failed ip bbb b port ccccc func ddd d errno eee detail ff gggg Classification NOTICE Explanation Failed in building the control path a Disk array specifying number in environment definition file UNIX system 1 to 64 Windows system 1 to 32 bbb b IP address ccccc Port number ddd d Function name eee Error number ff gggg Detail information This co...

Page 42: ...asures Remove the hindrance by checking the network connection status between iSM server and disk array and restart the server if necessary iSM03132 Management of control path in diskarray a failed ip bbb b port ccccc reason invalid sequence detail dd eeee Classification NOTICE Explanation Failed in the inclusion of the control path a Disk array specifying number in environment definition file UNI...

Page 43: ...tus between iSM server and disk array and restart the server if necessary iSM03134 Management of control path in diskarray a failed ip bbb b port ccccc command ddd d status ee ff gg hh detail ii jjjj Classification NOTICE Explanation Failed in the inclusion of the control path a Disk array specifying number in environment definition file UNIX system 1 to 64 Windows system 1 to 32 bbb b IP address ...

Page 44: ... Measures Check the function name and error number and resolve the hindrance iSM03140 Management of control path in diskarray a failed Disk disk bbb Port ccc Bus ddd Target eee Lun fff func ggg g errno hhh detail ii jjjj Classification NOTICE Explanation Failed in the inclusion of the control path This message is output on Windows system a Disk array specification number 1 to 32 in the environment...

Page 45: ... Measures Check the status of the disk array and remove the cause of failure iSM03141 Management of control path in diskarray a failed Disk disk bbb Port ccc Bus ddd Target eee Lun fff command ggg g status hh ii jj kk detail ll mmmm Classification NOTICE Explanation Failed in the inclusion of the control path This message is output on Windows system a Disk array specification number 1 to 32 in the...

Page 46: ... Measures Check the status of the disk array and remove the cause of failure iSM03142 Management of control path in diskarray a failed Disk disk bbb Port ccc Bus ddd Target eee Lun fff command ggg g status hhhhhhhh detail ii jjjj Classification NOTICE Explanation Failed in the inclusion of the control path This message is output on Windows system a Disk array specification number 1 to 32 in the en...

Page 47: ...name and error number to remove the failure and restart iSM server if necessary iSM03150 Management of control path by autofind failed Disk disk aaa Port bbb Bus ccc Target ddd Lun eee func fff f errno ggg detail hh iiii Classification INFO Explanation Failed in the inclusion of the control path by auto find function The disk with error cannot be included to iSM server iSM server will ignore error...

Page 48: ...sk array and remove the cause of failure Restart the iSM server if necessary iSM03151 Management of control path by autofind failed Disk disk aaa Port bbb Bus ccc Target ddd Lun eee command fff f status gg hh ii jj detail kk llll Classification INFO Explanation Failed in the inclusion of the control path by auto find function The disk with error cannot be included in iSM server iSM server will ign...

Page 49: ...sk array and remove the cause of failure Restart the iSM server if necessary iSM03152 Management of control path by autofind failed Disk disk aaa Port bbb Bus ccc Target ddd Lun eee command fff f status gggggggg detail hh iiii Classification INFO Explanation Failed in the inclusion of the control path by auto find function The disk information that becomes an error cannot be included in iSM server...

Page 50: ...emove the failure Restart the monitoring manually if necessary iSM03201 Control path access failed ip aaa a port bbbbb command ccc c status dd ee ff gg detail hh iiii Classification ERROR Explanation Error occurred in the access of the control path aaa a IP address bbbbb Port number ccc c Command Descriptor Block of the issued command dd Status Byte ee Sense Key ff Additional Sense Code gg Additio...

Page 51: ...alue for maintenance Measures Check the status of the disk array and remove the cause of failure Restart the monitoring manually if necessary iSM03204 Control path access failed ip aaa a port bbbbb reason invalid sequence detail cc dddd Classification ERROR Explanation Error occurred in the access of the control path aaa a IP address bbbbb Port number cc dddd Detail information This code isn t dis...

Page 52: ...or maintenance Measures Check the status of the disk array and remove the cause of failure Restart the monitoring manually if necessary iSM03220 Control path access failed file aaa a func bbb b errno ccc detail dd eeee Classification ERROR Explanation Error occurred in the access of the control path This message is output on UNIX system aaa a Special file name bbb b Function number ccc Error numbe...

Page 53: ...n name and error number and resolve the hindrance Restart the monitoring manually if necessary iSM03221 Control path access failed file aaa a command bbb b status cc dd ee ff detail gg hhhh Classification ERROR Explanation Error occurred in the access of the control path This message is output on UNIX system aaa a Special file name bbb b Command Descriptor Block of the issued command cc Status Byt...

Page 54: ...ation This code isn t disorder reason but a value for maintenance Measures Check the status of the disk array and remove the cause of failure Restart the monitoring manually if necessary iSM03222 Control path access failed file aaa a command bbb b status cccccccc detail dd eeee Classification ERROR Explanation Error occurred in the access of the control path This message is output on UNIX system a...

Page 55: ...res Check the status of the disk array and remove the cause of failure Restart the monitoring manually if necessary iSM03224 Control path is blockaded file aaa a func bbb b errno ccccc status ddd d eee e productID fffff SN ggggg UC hhhhhhhh FC ii Classification ERROR Explanation The control path special file access was blockaded This message is output on UNIX system aaa a Special file name bbb b F...

Page 56: ... path disk access was blockaded This message is output on Windows system diskaaa Portbbb Busccc Targetddd Luneee Disk information fff f Function number ggggg Error number hhh h Result of issuing of SCSI command iii i Disk array name jjjjj Product ID of disk array for example S2100 Disk Array etc kkkkk Serial number of disk array llllllll mm Maintenance information Measures Check the status of the ...

Page 57: ...ance information Measures Check the status of the disk array and remove the cause of failure iSM03225 Data can not be gotten sequentially during split mode Disk disk aaa Port bbb Bus ccc Target ddd Lun eee reason invalid sequence detail ff gggg Classification ERROR Explanation Obtaining data failed in command divided transfer The message indicates that retry processing could not obtain correct dat...

Page 58: ...bb Product ID of disk array NEC Storage S2100 etc ccccc Serial number of disk array dd eeee Detailed information This code isn t disorder reason but a value for maintenance Measures Check the status of the disk array and remove the cause of failure If necessary restart monitoring manually iSM03300 SVP has restarted ip aaa a detail bb cccc Classification INFO Explanation Service processor SVP has b...

Page 59: ...e SNMP trap can not be collected detail aa bbbb Classification WARNING Explanation The SNMP TRAP receiving is not possible because the SNMP TRAP receiving port number 162 of the server operated by iSM server cannot be used Therefore swift collecting of trouble information is not available and it has to be collected by polling The port may be used by other application aa bbbb Detail information Thi...

Page 60: ...on This code isn t disorder reason but a value for maintenance Measures Unnecessary iSM03400 File access failed func aaa a path bbb b errno ccc detail dd eeee Classification ERROR Explanation An error occurred in the file access function The iSM server terminates abnormally aaa a Function number bbb b Path name ccc Error number dd eeee Detail information This code isn t disorder reason but a value...

Page 61: ...ck the function name and error number and resolve the hindrance Restart the iSM server if necessary iSM03411 Socket access failed func aaa a path bbb b errno ccc detail dd eeee Classification ERROR Explanation Error occurred in the socket access function iSM server will be terminated abnormally aaa a Function number bbb b Socket path ccc Error number dd eeee Detail information This code isn t diso...

Page 62: ...ollowing information and restart iSM server iSM operation log syslog for other than Windows event log for Windows iSM03420 Memory access failed func aaa a errno bbb detail cc dddd Classification ERROR Explanation Error occurred in the memory access function iSM server will be terminated abnormally This message is output on UNIX system aaa a Function number bbb Error number cc dddd Detail informati...

Page 63: ...his code isn t disorder reason but a value for maintenance Measures Check the function name and error number and resolve the hindrance Restart the iSM server if necessary iSM03440 iSMmknod is running detail aa bbbb Classification ERROR Explanation iSM server cannot be activated because iSMmknod command is being executed This message is output on UNIX system aa bbbb Detailed information This code i...

Page 64: ...nment definition file iSM03442 iSMvollist is running detail aa bbbb Classification ERROR Explanation It shows that the iSM server cannot be started because iSMvollist command is running aa bbbb Detail information This code isn t disorder reason but a value for maintenance Measures Restart the iSM server after iSMvollist command ended iSM03500 Internal error occurred detail aa bbbb Classification E...

Page 65: ...busy when it terminates emergency Unexpected error message maybe generated Classification WARNING Explanation It indicates that the agent management detected an emergency stop but the process is unable to terminate immediately Measures Unnecessary ...

Page 66: ...n It shows that an internal error has occurred aaaaa Internal code bbbbb Error number Measures Check the server operation environment and the various settings iSM04022 Message send error has occurred process aaa a reason bbb Classification WARNING Explanation Failed in the transmission to the message queue This message is output on UNIX system Output only to syslog aaa a Process name bbb Reason of...

Page 67: ...ning the log file in order to return it into the initial status Before deleting the files under the directory make the backup copies of the files if necessary iSM04024 File read error has occurred file aaa a Classification ERROR Explanation Failed in reading the file aaa a File name Measures Check the status of applicable file Read out authority etc If a generation management file iSM_Log cnt name...

Page 68: ...ormally Terminate the iSM server and then delete files under the directory containing the log file in order to return it into the initial status Before deleting the files under the directory make the backup copies of the files if necessary iSM04030 Last message repeated aaa times Classification INFO Explanation The same message is being output repeatedly aaa Repeating time Measures Unnecessary iSM...

Page 69: ...sage List 64 iSM04060 Log File write started host aaa a Classification INFO Explanation It shows that writing into the operation log has started aaa a Host name of the machine running iSM server Measures Unnecessary ...

Page 70: ...fication NOTICE Explanation It shows that an internal error has occurred aaaaa Internal code bbbbb Error number Measures Check the server operation environment and various settings iSM06029 Message driven definition file does not exist file aaa a Classification WARNING Explanation It shows that message driven definition file does not exist aaa a File name Measures If using the message driven funct...

Page 71: ...xplanation It indicates that reading the message driven definition file has failed aaa Error line number bbbbb Error number Measures Check the status of the definition file such as the reading authority The definition files are stored in the following For UNIX etc iSMsvr msgdrv conf For Windows installation directory conf iSMsvr msgdrv conf iSM06032 Message driven definition file error First line ...

Page 72: ... It indicates that it is the applicable line of message driven definition file and the first word is not a keyword aaa Error line number Measures Take the measures below For UNIX Check the syntax of the definition file and describe it correctly For Windows Check the link information in the environment setting and specify the setting again iSM06035 Message driven definition file error does not exis...

Page 73: ...inition file and describe parentheses correctly For Windows Check the link information in the environment setting and specify the setting again iSM06037 Message driven definition file error SMTP is not defined Classification WARNING Explanation It indicates that there is no definition of SMTP in the message driven definition file Measures Take the measures below For UNIX Check the syntax of the de...

Page 74: ...link information in the environment setting and specify the setting again iSM06039 Message driven definition file error shell and mail exceeded 10 line aaa Classification WARNING Explanation It indicates that definition number of either shell or mail at the same level exceeded 10 in the applicable line of the message driven definition file aaa Error line number Measures Take the measures below For...

Page 75: ... that reading a header file has failed aaaaa Error number Measures Check header file name header file name specified in message driven definition file on UNIX system or mail header file name specified in link information of environment settings on Windows system and check the state of the file such as reading authority etc iSM06042 Header file s mail body size over 1024 bytes Classification WARNIN...

Page 76: ... is written next to first FROM in the header file Measures Check header file name header file name specified in message driven definition file on UNIX system or mail header file name specified in link information of environment settings on Windows system and check the first line of the file iSM06045 Header file error Line exceeds 256 bytes line aaa Classification WARNING Explanation It indicates t...

Page 77: ...in message driven definition file on UNIX system or shell file specified in link information of environment settings on Windows system must be created in advance for preparation iSM06051 Shell file is not executable file aaa a Classification WARNING Explanation It indicates that shell file cannot be executed aaa a File name Measures A shell file shell file specified in message driven definition fi...

Page 78: ...nition file on UNIX system or mail server specified by link information of environment settings on Windows system Check addresses and operations of defined mail server iSM06063 Recv error from mail server name aaa a code bbbbb errno ccccc Classification WARNING Explanation It indicates that receiving from the mail server has failed aaa a Function name bbbbb Internal code ccccc Error number 0 indic...

Page 79: ... Classification WARNING Explanation It indicates that the communication error occurred with mail server a Internal code number bbb b Transmission information ccc c Reception information Measures Check the operation of the defined mail server and resolve the problem based on the information iSM06066 Mail server time out Classification WARNING Explanation It indicates that the operation of the mail ...

Page 80: ...vered Classification WARNING Explanation It indicates that the message lost by the overflow of message buffer has been recovered This message is output on UNIX system Output only to syslog Measures This message is output in pair with iSM06070 which indicates that too many messages to be linked exist and indicates recovery of the error indicated by iSM06070 Refer to iSM06070 for the recovery proces...

Page 81: ...tinues to operate by previous definition Classification WARNING Explanation The definition change was failed The driven function operates by the old function before changing Measures While trying to change the definition with iSM server operating the definition error occurred Correct the definition error and execute the change command again iSM06083 Making directory for core dump file error code a...

Page 82: ...name bbb b Directory name ccccc Error number Measures There is an error in the authority of installation directory and so on iSM06086 Mail process count over This message is canceled msg aaa a Classification WARNING Explanation The mail of the applicable message could not be transmitted because the processing number of mail transmission and shell start per one minute exceeded the limit The driving...

Page 83: ...ss is not executed aaa a Message Measures Number of mails and shell start by driving is too much The definition should be reviewed or the way of mail transmission or shell start operating method should be considered iSM06088 Message driven processing stopped for excess of number of processes was resumed Classification WARNING Explanation The driving process which has been cancelled because the pro...

Page 84: ...rrect the definition For Windows Check the link information in the environment setting and specify the setting again iSM06092 Message driven definition file error Number of is not right line aaa Classification WARNING Explanation It indicates that is not suitable in the applicable line of the message driven definition file aaa Error line number Measures Take the measures below For UNIX Check the a...

Page 85: ...anation It indicates that incorrect description exists in the message driven definition file a Error Classification 0 Some character follows the SERVER or LEVEL 1 A position of is inappropriate or does not exist 2 No character follows 3 Invalid character exists in the end of line 4 A position of is inappropriate 5 A position of is inappropriate 6 A position of is inappropriate 7 A position of shel...

Page 86: ...aa a error contents system call error System call error file definition error File description error internal error Internal error bbb b System function name ccc Error number ddd Error line number eee e Detailed information message ID not found No valid message ID Double definition of message ID Message ID defined duplicately value of registry is wrong Invalid registry Measures Take appropriate me...

Page 87: ...k Array etc ccccc Serial number of disk array Measures Unnecessary iSM07012 Resource monitoring started aaa a productID bbbbb SN ccccc UC dddddddddd FC ee Classification INFO Explanation It indicates that state monitoring to disk array name aaa a started This message is output at start from the fault status aaa a Disk array name bbbbb Product ID of disk array for example S2100 Disk Array etc ccccc...

Page 88: ...mber of disk array Measures Unnecessary iSM07022 Resource monitoring stopped for maintenance aaa a productID bbbbb SN ccccc Classification INFO Explanation It indicates that state monitoring to disk array name aaa a was stopped because the status of maintenance operation was detected aaa a Disk array name bbbbb Product ID of disk array for example S2100 Disk Array etc ccccc Serial number of disk a...

Page 89: ...m related other messages and restart the monitoring after the trouble recovery The monitoring can be restarted from iSM client iSM07024 Resource monitoring stopped by information collecting failure aaa a productID bbbbb SN ccccc UC dddddddddd FC ee Classification ERROR Explanation It indicates that state monitoring to disk array Name aaa a has been stopped by information collecting failure aaa a D...

Page 90: ...changes to recovery mode aaa a productID bbbbb SN ccccc UC dddddddddd FC ee Classification ERROR Explanation It indicates that the monitoring for the disk array Name aaa a became impossible to continue due to disk array failure or control path failure and the system is turned into the monitoring recovery waiting status aaa a Disk array name bbbbb Product ID of disk array for example S2100 Disk Arr...

Page 91: ... to stop monitoring resource is waiting for terminate of other request aaa a Classification INFO Explanation It indicates that a state monitoring stop command to disk array Name aaa a is waiting for the end of other command processing The monitoring of disk array automatically stops after the end of the processing that has been requested aaa a Disk array name Measures Unnecessary iSM07033 Request ...

Page 92: ... that an attempt has been made to restart state monitoring to disk array name aaa a that stopped operation due to failure aaa a Disk array name Measures Unnecessary iSM07091 Control path access to aaa a failed status bbbb h cc h dddddddd h eeeeeeee h ffffff h Classification WARNING Explanation It indicates that the administration command to disk array name aaa a ended due to an error aaa a Disk ar...

Page 93: ... the iSM server is blockaded Measures Collect information and restart the iSM server if necessary For how to collect the information refer to 6 1 9 Information Gathering Method when Server Fault with Unknown Cause of the NEC Storage Manager User s Manual iSM07094 Illegal data has detected aaa a productID bbbbb SN ccccc status ddddd h eeeee h Classification ERROR Explanation It indicates that a res...

Page 94: ... disk array Measures Check the resource with incorrect configuration and correct the configuration iSM07101 State of PD aa h has become ready bbb b productID ccccc SN ddddd No ee h ff h RankNo gg h ii h Classification INFO Explanation It indicates that the physical disk number ee ff of disk array name bbb b has become ready aa Internal number indicating physical disk type bbb b Disk array name ccc...

Page 95: ...g hh RANK number that the physical disk belongs to Measures Check the status of resource with the trouble and perform the appropriate maintenance iSM07104 State of PD aa h has become attn rebuilding bbb b productID ccccc SN ddddd No ee h ff h RankNo gg h hh h Classification NOTICE Explanation It indicates that the physical disk number ee ff of disk array name bbb b is rebuilding data aa Internal n...

Page 96: ... disk belongs to Measures Unnecessary It usually becomes ready within a few seconds If the status does not become ready perform the appropriate maintenance because some trouble may occur iSM07106 State of PD aa h has become attn formatting bbb b productID ccccc SN ddddd No ee h ff h RankNo gg h hh h Classification NOTICE Explanation It indicates that the physical disk number ee ff of disk array na...

Page 97: ... number that the physical disk belongs to Measures Check the physical disk in which the state transition occurred and perform the appropriate maintenance iSM07109 State of PD aa h has become ready bbb b productID ccccc SN ddddd No ee h ff h RankNo gg h hh h Classification INFO Explanation It indicates that the status of the physical disk number ee ff of disk array name bbb b changed from in troubl...

Page 98: ...ponent number except for logical disk physical disk Measures Unnecessary iSM07112 State of aaaaa bb h cc h has become fault ddd d productID eeeee SN fffff No gg h Classification ERROR Explanation It indicates that trouble occurred in the component abbreviated name aaaaa number gg of disk array name ddd d aaaaa Abbreviated name of component bb cc Internal number indicating component type ddd d Disk...

Page 99: ...umber except for logical disk physical disk Measures Check the resource in which the state transition occurred and perform the appropriate maintenance iSM07114 State of HD aa h has become attn nolicense bbb b productID ccccc SN ddddd No ee h Classification ERROR Explanation The program product NEC Storage BaseProduct has not been installed and the host director number ee of the disk array name bbb...

Page 100: ...Logical disk number eee e Logical disk name Measures Unnecessary iSM07122 State of LD has become fault aaa a productID bbbbb SN ccccc No dddd h Name eee e Classification ERROR Explanation It indicates that trouble media error occurred in the logical disk number dddd name eee e of disk array name aaaaa aaa a Disk array name bbbbb Product ID of disk array for example S2100 Disk Array etc ccccc Seria...

Page 101: ...heck the status of the logical disk with the trouble and perform the appropriate maintenance iSM07124 State of LD has become attn reduce aaa a productID bbbbb SN ccccc No dddd h Name eee e Classification ERROR Explanation It indicates that the logical disk number dddd name eee e of disk array name aaa a has become a reduced state RAID composition which lost redundancy by PD trouble aaa a Disk arra...

Page 102: ...mber eee e Logical disk name Measures In relation to the measures for the logical disk caused by state transition refer to the other applicable messages iSM07126 State of LD has become attn preventive copy aaa a productID bbbbb SN ccccc No dddd h Name eee e Classification NOTICE Explanation It indicates that data in the logical disk number dddd name eee e of disk array name aaa a has been copied i...

Page 103: ... dddd Logical disk number eee e Logical disk name Measures Unnecessary iSM07128 State of LD has become attn unformatted aaa a productID bbbbb SN ccccc No dddd h Name eee e Classification NOTICE Explanation It indicates that the logical disk number dddd name eee e of disk array name aaa a has been unformatted logically aaa a Disk array name bbbbb Product ID of disk array for example S2100 Disk Arra...

Page 104: ...ray dddd Logical disk number eee e Logical disk name Measures Unnecessary iSM07130 State of LD has become attn format fail aaa a productID bbbbb SN ccccc No dddd h Name eee e Classification NOTICE Explanation It indicates that the logical disk number dddd name eee e of disk array name aaa a failed in formatting logically aaa a Disk array name bbbbb Product ID of disk array for example S2100 Disk A...

Page 105: ...y dddd Logical disk number eee e Logical disk name Measures Unnecessary iSM07132 State of LD has become attn expand fail aaa a productID bbbbb SN ccccc No dddd h Name eee e Classification NOTICE Explanation It indicates that the logical disk number dddd name eee e of disk array name aaa a failed in logical expansion aaa a Disk array name bbbbb Product ID of disk array for example S2100 Disk Array ...

Page 106: ...c ccccc Serial number of disk array dd ee RANK number Measures Unnecessary iSM07142 State of RANK has become fault aaa a productID bbbbb SN ccccc No dd h ee h Classification ERROR Explanation It indicates that a trouble occurred in the RANK number dd ee of disk array name aaa a aaa a Disk array name bbbbb Product ID of disk array for example S2100 Disk Array etc ccccc Serial number of disk array d...

Page 107: ...umber of disk array dd ee RANK number Measures Check the status of the RANK with the trouble and perform the appropriate maintenance iSM07144 State of RANK has become attn rebuilding aaa a productID bbbbb SN ccccc No dd h ee h Classification NOTICE Explanation It indicates that the RANK number dd ee of disk array name aaa a is rebuilding data aaa a Disk array name bbbbb Product ID of disk array fo...

Page 108: ...disk array for example S2100 Disk Array etc ccccc Serial number of disk array dd ee RANK number Measures Unnecessary iSM07146 State of RANK has become attn copy back aaa a productID bbbbb SN ccccc No dd h ee h Classification NOTICE Explanation It indicates that data in the RANK number dd ee of disk array name aaa a has been restored from spare disk aaa a Disk array name bbbbb Product ID of disk ar...

Page 109: ...cccc Serial number of disk array dd ee RANK number Measures Unnecessary iSM07148 State of RANK has become attn expand fail aaa a productID bbbbb SN ccccc No dd h ee h Classification NOTICE Explanation It indicates that the rank number dd ee of disk array name aaa a failed in logical expansion aaa a Disk array name bbbbb Product ID of disk array for example S2100 Disk Array etc ccccc Serial number ...

Page 110: ... physical disk belong to Measures Unnecessary iSM07152 State of PD aa h has become fault bbb b productID ccccc SN ddddd No ee h ff h RankNo gg h hh h UC iiiiiiii FC jj Classification ERROR Explanation It indicates that a trouble occurred in the physical disk number ee ff of disk array name bbb b aa Internal number indicating physical disk type bbb b Disk array name ccccc Product ID of disk array f...

Page 111: ...sk belong to iiiiiiii jj Maintenance information Measures Unnecessary iSM07155 State of PD aa h has become attn powering up bbb b productID ccccc SN ddddd No ee h ff h RankNo gg h hh h Classification NOTICE Explanation It indicates that the physical disk number ee ff of disk array name bbb b is activated aa Internal number indicating physical disk type bbb b Disk array name ccccc Product ID of dis...

Page 112: ... RANK number that the physical disk belong to Measures Unnecessary iSM07158 State of PD aa h has become offline bbb b productID ccccc SN ddddd No ee h ff h RankNo gg h hh h Classification ERROR Explanation It indicates that the physical disk number ee ff of disk array name bbb b has been in the off line status aa Internal number indicating physical disk type bbb b Disk array name ccccc Product ID ...

Page 113: ...f disk array ee ff Physical disk number gg hh RANK number that the physical disk belong to iiiiiiii jj Maintenance information Measures Unnecessary iSM07161 State of aaaaa bb h cc h has become ready ddd d productID eeeee SN fffff No gg h Classification INFO Explanation It indicates that the component abbreviated name aaaaa number gg of disk array name ddd d has become ready aaaaa Abbreviated name ...

Page 114: ...t for logical disk physical disk Measures Check the status of the resource with the trouble and perform the appropriate maintenance iSM07163 State of aaaaa bb h cc h has become offline ddd d productID eeeee SN fffff No gg h Classification ERROR Explanation It indicates that the component abbreviated name aaaaa number gg of disk array name ddd d has become removed or not existed aaaaa Abbreviated n...

Page 115: ...ple S2100 Disk Array etc ddddd Serial number of the disk array ee Component number except for logical disk physical disk Measures Install the program product NEC Storage BaseProduct for the host director iSM07171 State of LD has become ready aaa a productID bbbbb SN ccccc No dddd h Name eee e Classification INFO Explanation It indicates that the logical disk number dddd name eee e of disk array na...

Page 116: ...the logical disk with the trouble and perform the appropriate maintenance iSM07173 State of LD has become fault media error aaa a productID bbbbb SN ccccc No dddd h Name eee e UC ffffffffff FC gg Classification ERROR Explanation It indicates that trouble media error occurred in the logical disk number dddd name eee e of disk array name aaa a aaa a Disk array name bbbbb Product ID of disk array for...

Page 117: ...mber eee e Logical disk name Measures Check the status of the logical disk with the trouble and perform the appropriate maintenance iSM07175 State of LD has become attn rebuilding aaa a productID bbbbb SN ccccc No dddd h Name eee e Classification NOTICE Explanation It indicates that the logical disk number dddd name eee e of disk array name aaa a is rebuilding data aaa a Disk array name bbbbb Prod...

Page 118: ...sk Array etc ccccc Serial number of disk array dddd Logical disk number eee e Logical disk name Measures Unnecessary iSM07177 State of LD has become attn copy back aaa a productID bbbbb SN ccccc No dddd h Name eee e Classification NOTICE Explanation It indicates that data in the logical disk number dddd name eee e of disk array name aaa a has been restored from spare disk aaa a Disk array name bbb...

Page 119: ...dd Logical disk number eee e Logical disk name Measures In relation to the measures for resources caused by state transition refer to the other applicable messages iSM07179 State of LD has become attn formatting aaa a productID bbbbb SN ccccc No dddd h Name eee e Classification NOTICE Explanation It indicates that the logical disk number dddd name eee e of disk array name aaa a is being formatted ...

Page 120: ...disk array dddd Logical disk number eee e Logical disk name Measures Check the status of the resource with the trouble and perform the appropriate maintenance iSM07181 State of LD has become attn expanding aaa a productID bbbbb SN ccccc No dddd h Name eee e Classification NOTICE Explanation It indicates that the logical disk number dddd name eee e of disk array name aaa a is expanding the logic aa...

Page 121: ... Array etc ccccc Serial number of disk array dddd Logical disk number eee e Logical disk name Measures Check the status of the resource with the trouble and perform the appropriate maintenance iSM07191 State of RANK has become ready aaa a productID bbbbb SN ccccc No dd h ee h Classification INFO Explanation It indicates that the RANK number dd ee of disk array name aaa a has become ready aaa a Dis...

Page 122: ...nce information Measures Check the status of the RANK with the trouble and perform the appropriate maintenance iSM07193 State of RANK has become attn reduce aaa a productID bbbbb SN ccccc No dd h ee h Classification ERROR Explanation It indicates that the RANK number dd ee of disk array name aaa a has become in reduced state RAID composition which lost redundancy by PD trouble aaa a Disk array nam...

Page 123: ...e RANK number Measures In relation to the measures for the RANK caused by state transition refer to the other applicable messages iSM07195 State of RANK has become attn preventive copy aaa a productID bbbbb SN ccccc No dd h ee h Classification NOTICE Explanation It indicates that data in the RANK number dd ee of disk array name aaa a has been copied into spare disk This message is output on UNIX s...

Page 124: ... ID of disk array for example S2100 Disk Array etc ccccc Serial number of disk array dd ee RANK number Measures Unnecessary iSM07197 State of RANK has become attn expanding aaa a productID bbbbb SN ccccc No dd h ee h Classification NOTICE Explanation It indicates that the rank number dd ee of disk array name aaa a is expanding the logic aaa a Disk array name bbbbb Product ID of disk array for exam...

Page 125: ...ct ID of disk array for example S2100 Disk Array etc ccccc Serial number of disk array dd ee RANK number Measures Check the status of the resource with the trouble and perform the appropriate maintenance iSM07201 Disk Array named aaa a has renamed to bbb b SN ccccc Classification INFO Explanation It indicates that the name of disk array name aaa a serial number ccccc has been changed to bbb b aaa ...

Page 126: ...o bbb b ccc c No dddd h Classification INFO Explanation It indicates that the logical disk number ccc c name of disk array name dddd has been changed from aaa a to bbb b aaa a Old Logical disk name bbb b New Logical disk name ccc c Disk array name dddd Logical disk number Measures Unnecessary iSM07204 Name setting has executed with SG file aaa a Classification INFO Explanation It indicates that th...

Page 127: ...E Explanation It indicates that the cache disk configuration of disk array name aaa a has been changed aaa a Disk array name Measures Unnecessary iSM07207 Attribute of PD has changed from aaaaa to bbbbb ccc c No dd h ee h Classification NOTICE Explanation It indicates that partition data spare in the physical disk number dd ee of disk array name ccc c has been changed aaaaa Old partition bbbbb New...

Page 128: ...ge of disk array names name aaa a serial number bbbbb failed aaa a Disk array name bbbbb Serial number Measures Check result indicated on client screen dialog and remove cause of the failure Then change the names again iSM07212 Renaming PORT of aaa a is failed No bb h cc h Classification INFO Explanation It indicates that change of port number bb cc of disk array name aaa a failed aaa a Disk array...

Page 129: ...sification INFO Explanation It indicates that service processor number component number dd of disk array name aaa a has been changed aaa a Disk array name bbbbb Product ID of disk array for example S2100 Disk Array etc ccccc Serial number of disk array dd Component number of service processor Measures Unnecessary iSM07221 Product information was changed aaa a productID bbbbb SN ccccc Classificatio...

Page 130: ...ame aaa a exists in others bbb b No cc h dd h Classification WARNING Explanation It indicates that the name aaa a of port number cc dd of the disk array name bbb b is duplicated aaa a Port name bbb b Disk array name cc dd Port number Measures Check the ports with the same name and correct the name iSM07253 LD name aaa a exists in others bbb b No cccc h Classification WARNING Explanation It indicat...

Page 131: ...ted bbb b Classification INFO Explanation It indicates that LD_SET name aaa a is deleted from disk array name bbb b aaa a LD_SET name bbb b Disk array name Measures Unnecessary iSM07303 PATH aaa a was added to LD_SET bbb b LD_SET ccc c Classification INFO Explanation It indicates that the path aaa a is added to LD_SET name ccc c of disk array name bbb b aaa a Path aaaa aaaa aaaa aaaa WWPN aah aah ...

Page 132: ...were assigned to LD_SET aaa a LD_SET bbb b PATH ccc c Classification INFO Explanation It indicates that LDs are assigned to LD_SET name bbb b of disk array name aaa a and the path cccc cccc cccc cccc aaa a Disk array name bbb b LD_SET name ccc c Path cccc cccc cccc cccc WWPN cch cch Port number Measures Unnecessary iSM07306 Some of LDs were assigned to LD_SET aaa a LD_SET bbb b Classification INFO...

Page 133: ...h bbh Port number ccc c Disk array name ddd d LD_SET name Measures Unnecessary iSM07308 LD named aaa a bbbb h was added to LD_SET ccc c LD_SET ddd d PATH eee e Classification INFO Explanation It indicates that the logical disk name aaa a number bbbb is added to LD_SET name ddd d of disk array name ccc c and the logical disk is accessible via the path eee e aaa a Logical disk name bbbb Logical disk...

Page 134: ... array name ddd d LD_SET name Measures Unnecessary iSM07310 LD named aaa a bbbb h was deleted from LD_SET ccc c LD_SET ddd d PATH eee e Classification INFO Explanation It indicates that the logical disk name aaa a number bbbb is added to LD_SET name ddd d of disk array name ccc c and the logical disk is inaccessible via the path eee e aaa a Logical disk name bbbb Logical disk number ccc c Disk arr...

Page 135: ...easures Unnecessary iSM07312 ACCESS_CONTROL mode was changed into aaaa bbb b No cc h dd h Classification INFO Explanation It indicates that Access Control of port number cc dd of disk array name bbb b is changed to aaaa mode aaaa Access Control mode after changing WWN Port bbb b Disk array name cc dd Port number Measures Unnecessary iSM07313 ACCESS_CONTROL function was started aaa a Classification...

Page 136: ...o bbb b ccc c Classification INFO Explanation It indicates that LD_SET name of disk array name ccc c has been changed from aaa a to bbb b aaa a Old LD_SET name bbb b New LD_SET name ccc c Disk array name Measures Unnecessary iSM07316 Platform was re set up aaa a LD_SET bbb b Classification INFO Explanation It indicates that platform information for LD_SET name bbb b of disk array name aaa a has be...

Page 137: ...hat deleting the LD_SET name aaa a from disk array name bbb b failed aaa a LD_SET name bbb b Disk array name Measures Identify a cause of fault on the basis of previous and following messages remove the cause of fault and then retry processing iSM07333 Adding a PATH named aaa a to LD_SET was failed bbb b LD_SET ccc c Classification INFO Explanation It indicates that adding Path aaa a to LD_SET nam...

Page 138: ...fault on the basis of previous and following messages remove the cause of fault and then retry processing iSM07335 Assigning some of LDs to LD_SET was failed aaa a LD_SET bbb b PATH ccc c Classification INFO Explanation It indicates that assigning Logical Disk to LD_SET name bbb b of disk array name aaa a Path ccc c failed aaa a Disk array name bbb b LD_SET name ccc c Path cccc cccc cccc cccc WWPN...

Page 139: ...e of fault and then retry processing iSM07337 Exchanging a PATH from aaa a to bbb b was failed ccc c LD_SET ddd d Classification INFO Explanation It indicates that changing Path to LD_SET name ddd d of disk array name ccc c from aaa a to bbb b failed aaa a Path before change aaaa aaaa aaaa aaaa WWPN aah aah Port number bbb b Path after change bbbb bbbb bbbb bbbb WWPN bbh bbh Port number ccc c Disk...

Page 140: ...eeh eeh Port number Measures Identify a cause of fault on the basis of previous and following messages remove the cause of fault and then retry processing iSM07339 Adding a LD named aaa a bbbb h to LD_SET was failed ccc c LD_SET ddd d Classification INFO Explanation It indicates that adding Logical Disk name aaa a number bbbb to LD_SET name ddd d of disk array name ccc c failed aaa a Logical disk ...

Page 141: ...eh Port number Measures Identify a cause of fault on the basis of previous and following messages remove the cause of fault and then retry processing iSM07341 Deleting a LD named aaa a bbbb h from LD_SET was failed ccc c LD_SET ddd d Classification INFO Explanation It indicates that deleting Logical Disk name aaa a number bbbb from LD_SET name ddd d of disk array name ccc c failed aaa a Logical di...

Page 142: ...n was failed aaa a Classification INFO Explanation It indicates that starting Access Control function of disk array name aaa a failed aaa a Disk array name Measures Identify a cause of fault on the basis of previous and following messages remove the cause of fault and then retry processing iSM07344 Stopping ACCESS_CONTROL function was failed aaa a Classification INFO Explanation It indicates that ...

Page 143: ...g iSM07346 Re setup of Platform was failed aaa a LD_SET bbb b Classification INFO Explanation It indicates that re setup of the LD_SET name bbb b to disk array name aaa a failed aaa a Disk array name bbb b LD_SET name Measures Identify a cause of fault on the basis of previous and following messages remove the cause of fault and then retry processing iSM07501 Request is meaningless already Explana...

Page 144: ...t on UNIX system Measures Retry after checking the related resources iSM07505 Service stopped Explanation It indicates that the request cannot be executed since the NEC Storage Manager service is stopped This message is output on UNIX system Measures Unnecessary iSM07506 Request cancel Explanation It indicates that the request is cancelled since due to disk array failure etc This message is output...

Page 145: ...g processed for the disk array This message is output on UNIX system Measures Retry after the processing of the request is completed iSM07510 Invalid disk array id Explanation It indicates that the request cannot be executed since the target disk array cannot be identified in the state monitoring process This message is output on UNIX system Measures Retry after choking the status of the disk arra...

Page 146: ...us Measures Retry after checking that the disk array configuration setting is completed iSM07550 Program error has occurred code aaa a Classification NOTICE Explanation It indicates that an internal processing error occurred in the state monitoring process This message is output on UNIX system aaa a Internal error code Measures Investigate the cause with syslog or iSM operation log iSM07551 Time o...

Page 147: ...n NOTICE Explanation It indicates that signal reception caused the process end This message is output on UNIX system Measures Execute again If the same phenomenon recurs investigate the cause with syslog or iSM operation log iSM07554 Internal communication error has occurred code aaa a Classification NOTICE Explanation It indicates that error occurred in the coordination between state monitoring p...

Page 148: ...yslog or iSM operation log iSM07556 Insufficient resource has detected code aaa a Classification NOTICE Explanation It indicates that it failed to allocate the resources for internal processing in state monitoring process aaa a Internal error code Measures Execute again If the same phenomenon recurs investigate the cause with syslog or iSM operation log iSM07557 This function is not supported Expl...

Page 149: ...ion information after LD movement is completed for the disk array name aaa a aaa a Disk array name Measures Unnecessary iSM07611 Dataerase status is failed aaa a productID bbbbb SN ccccc No dddd h Name eee e Classification NOTICE Explanation It indicates that data initialization is failed for the logical disk number dddd name eee e in the disk array name aaa a aaa a Disk array name bbbbb Product I...

Page 150: ...isk array was detected by data retention function aaa a Name of disk array that detected invalid write request bbbb Number of logical disk that detected invalid write request ccc c Server location on which illegal data writing was requested indicated by World Wide Port Name WWPN of Host Bus Adapter HBA Measures Locate a fault and re execute transaction as required iSM07981 Message output failed aa...

Page 151: ...M08021 Disk array aaa a logging is stopped Classification INFO Explanation It indicates that accumulation into statistics information history file has been stopped aaa a Disk array name Measures Unnecessary iSM08022 Disk array aaa a logging interval has changed interval bb Classification NOTICE Explanation It indicates that data accumulation changed interval on statistic information history file a...

Page 152: ... is already stopped Classification NOTICE Explanation It indicates that accumulation into statistics information history file has already been stopped aaa a Disk array name Measures Check whether the specified disk array name is correct iSM08032 Disk array aaa a is not monitored Classification NOTICE Explanation It indicates that specified disk array is not monitored aaa a Disk array name Measures...

Page 153: ...n a option of starting stopping accumulation into statistics information history file was executed for all disk array with a iSMprflog start command Measures Check the status of disk array and if necessary execute the command again iSM08035 Disk array aaa a logging is started overload interval bb Classification NOTICE Explanation It indicates that accumulation into statistics information history f...

Page 154: ...tion history file 2 Stop monitoring and execute trouble maintenance And then start the monitoring and execute the operation to start accumulation into statistics information history file again iSM08037 Disk array aaa a is overload limit bbbb residual cccc Classification NOTICE Explanation It indicates that disk array is overloaded aaa a Disk array name bbbb Upper limit of count for statistic infor...

Page 155: ...e Transfer Rate avlen Average Transfer Length avresp Average Response Time readhit Read Hit Ratio writehit Write Hit Ratio busy Busy Ratio eee e Performance data value ffff Monitoring item value ggg g Threshold value Measures Research the access status of components with exceeded thresholds as necessary iSM08051 Performance monitoring overhead exceeds permissible amount disk array aaa a Classifica...

Page 156: ...al min or sec ccc Minimum number of I Os Measures Unnecessary iSM08053 Condition to reset threshold excess state has changed interval aa time bb cc Classification NOTICE Explanation It indicates that threshold excess release conditions have been changed aa Threshold excess release interval threshold monitoring count If no value is specified asterisk is displayed interval bb cc Threshold excess rel...

Page 157: ...avresp Average Response Time readhit Read Hit Ratio writehit Write Hit Ratio busy Busy Ratio Measures Unnecessary iSM08055 Saving of threshold monitoring object failed disk array aaa a func bbb b errno cccc detcode dddddddd Classification WARNING Explanation It indicates that storing of threshold value failed aaa a Disk array name bbb b Name of function in which an error occurred cccc Error number...

Page 158: ...n in which an error occurred cccc Error number dddddddd Detail code Measures Input error of threshold saving file or shortened display refresh rate is suspected as a possible cause Against an input error of threshold saving file remove the cause of file system failure and then restart the iSM server Against shortened display refresh rate detcode 01660086 restore the display refresh rate to a previ...

Page 159: ... the environment definition file has no writing permission errno 13 detcode 0122f026 0122f025 It failed in the open access close processing of statistics information history file due to shortage of disk space errno 2 4 28 detcode 0122f026 01220031 01220032 0122f033 0122f035 01230013 012300 14 01260030 01260031 01100002 0122f011 0122f025 Access error of disk occurred errno 5 detcode 01220031 012200...

Page 160: ...t a statistics information history file has already existed In this case a new file is created by assigning a file sequence number to the existing statistics information history file name and accumulation of statistics information will normally start aaa a Disk array name bbb b File name finally determined Measures Unnecessary iSM08070 Make directory failed dirname aaa a errno bbbb detcode ccccccc...

Page 161: ...no bbbb detcode cccccccc Classification NOTICE Explanation It indicates that it failed to reserve resources shared memory aaa a Function name bbbb Error code cccccccc Detail code Measures Remove the cause of trouble and restart iSM server iSM08091 To create process failed func aaa a errno bbbb detcode cccccccc Classification NOTICE Explanation It indicates that it failed to generate the internal p...

Page 162: ...DD RD Statistics information of RD LD Statistics tics information of LD PD Statistics information of PD RANK Statistics information of RANK cccc ID number of component of failed information dddddddd Detail code Measures Investigate the state of disk array and remove the cause of trouble iSM08093 Failed in communication with aaaa func bbb b errno cccc detcode dddddddd Classification NOTICE Explanat...

Page 163: ...cccccc Detail code Measures Restart iSM server iSM08099 Program error occurred detcode aaaaaaaa Classification NOTICE Explanation It indicates that internal contradiction has been detected aaaaaaaa Detail code Measures Restart iSM server iSM08180 Accept new display refresh rate a times minute old b Classification NOTICE Explanation Display refresh rate was changed a Specified refresh rate b Refres...

Page 164: ...sh rate cannot be changed because a performance monitoring screen is displayed reduce threshold monitoring object Refresh rate cannot be changed due to excess number of threshold monitoring object bbb b Disk array name Measures Take the measures below If the change was failed because a performance monitoring client was being connected stop all performance monitoring clients Terminate all performan...

Page 165: ...rray aaa a type bbbb number cccc detcode dddddddd Classification NOTICE Explanation Performance data collected from HW is illegal aaa a Disk array name bbbb Type of performance data HD Statistical information of HD DD Statistical information of DD LD Statistical information of LD PD Statistical information of PD RANK Statistical information of RANK cccc Component ID number dddddddd Detail code Mea...

Page 166: ...ate emergency unexpected error message maybe generated Classification WARNING Windows Explanation The performance monitoring instructed emergency stop However process could not be stopped immediately This message is output on Windows system Measures Unnecessary ...

Page 167: ... Detail code Measures Restart iSM server iSM09002 Start LD movement from aaaa bbb b to cccc ddd d in eee e Classification NOTICE Explanation It indicates that logical disk movement starts aaaa Logical disk number of moved material logical disk bbb b Logical disk name of moved material logical disk cccc Logical disk number of work disk for Optimization ddd d Logical disk name of work disk for Optim...

Page 168: ...cccc Logical disk number of work disk for Optimization ddd d Logical disk name of work disk for Optimization eee e Disk array name fff f Error cause detcode xxxxxxxx Detail code terminated successfully Moving of the logical disk terminated normally terminated unsuccessfully Moving of the logical disk terminated abnormally stopped by user request The movement process suspended by user request Measu...

Page 169: ...f moved material logical disk cccc Logical disk number of work disk for Optimization ddd d Logical disk name of work disk for Optimization eee e Disk array name Measures Unnecessary iSM09005 Insufficient resource detected func aaa a errno bbbb detcode cccccccc Classification NOTICE Explanation It indicates that it has failed to acquire sufficient memory aaa a Function name bbbb Error code cccccccc...

Page 170: ...a Communication target bbb b Function name cccc Error code dddddddd Detail code Measures Remove the cause of the error and restart iSM server iSM09007 To create process failed func aaa a errno bbbb detcode cccccccc Classification NOTICE Explanation It indicates that it has failed to create internal process aaa a Function name bbbb Error code cccccccc Detail code Measures Remove the cause of the er...

Page 171: ...b Function name cccc Error code dddddddd Detail code Measures Remove the cause of the error and restart iSM server iSM09009 Change directory failed dirname aaa a func bbb b errno cccc detcode dddddddd Classification NOTICE Explanation It indicates that it has failed to move the directory aaa a Directory name bbb b Function name cccc Error code dddddddd Detail code Measures Remove the cause of the ...

Page 172: ...here is an error remove the cause of the error and execute the process again iSM09011 Request of stop LD movement from aaaa bbb b to cccc ddd d in eee e is rejected detcode ffffffff Classification NOTICE Explanation It indicates that the request to suspend moving process of the logical disk was rejected aaaa Logical disk number of moved material logical disk bbb b Logical disk name of moved materi...

Page 173: ...ffffff Detail code Measures Take the measures below Check the specification of the logical disk for which the movement speed is changed Check for the disk array status according to the related messages eliminate the error cause e g error recovery and then re execute the command iSM09013 To get subsystem information failed from disk array aaa a detcode bbbbbbbb Classification NOTICE Explanation It ...

Page 174: ...on shown in other message remove the cause and resume monitoring When monitoring is resumed the termination process for the logical disk movement is executed again iSM09015 Illegal LD movement information was received from aaa a Classification NOTICE Explanation It indicates that the following abnormality occurred in moving of logical disks 1 The movement information of the logical disk included i...

Page 175: ...l disks year month day hour minute kk Re execution continuing time when the Logical Disk could not be moved at scheduled time 1 to 24 unit hour Measures Unnecessary iSM09017 Request to register the schedule of LD movement from aaaa bbb b to cccc ddd d in eee e rejected detcode ffffffff Classification NOTICE Explanation It indicates that moving schedule of logical disks has been registered aaaa Log...

Page 176: ...n eee e Disk array name Measures Unnecessary iSM09019 Request to delete the schedule of LD movement from aaaa bbb b to cccc ddd d in eee e rejected detcode ffffffff Classification NOTICE Explanation It indicates that moving schedule of logical disks has been registered aaaa Logical disk number of moved material logical disk bbb b Logical disk name of moved material logical disk cccc Logical disk n...

Page 177: ... disks year month day hour minute kk Re execution continuing time when the Logical Disk could not be moved at scheduled time 1 to 24 unit hour Measures Unnecessary iSM09021 Request to change the schedule of LD movement from aaaa bbb b to cccc ddd d in eee e rejected detcode ffffffff Classification NOTICE Explanation It indicates that moving schedule of logical disks has been registered aaaa Logica...

Page 178: ...al disk cccc Logical disk number of work disk for Optimization ddd d Logical disk name of work disk for Optimization eee e Disk array name ffffffff Detail code Measures Retry moving of logical disks of failed moving process or re register the moving schedule iSM09099 Program error occurred detcode aaaaaaaa Classification NOTICE Explanation It indicates that internal contradiction is detected aaaaa...

Page 179: ...le name Measures Check the Bsl file and the file system remove the cause of the error and restart the iSM server iSM09102 Bsl file remove failed func aaa a errno bbbb detcode cccccccc filename ddd d Classification WARNING Explanation Failed to delete the Bsl file aaa a Function name bbbb Error code cccccccc Detail code ddd d Bsl file name Measures Check the Bsl file and the file system remove the ...

Page 180: ... file and the file system remove the cause of the error and restart the iSM server iSM09104 Bsl file write failed func aaa a errno bbbb detcode cccccccc rankno dddd filename eee e Classification WARNING Explanation Failed to write to the Bsl file aaa a Function name bbbb Error code cccccccc Detail code dddd RANK number of the data that could not be written eee e Bsl file name Measures Check the Bs...

Page 181: ...sl file name Measures Check the Bsl file and the file system remove the cause of the error and restart the iSM server iSM09106 Bsl file read failed func aaa a errno bbbb detcode cccccccc rankno dddd filename eee e Classification WARNING Explanation Failed to read the Bsl file aaa a Function name bbbb Error code cccccccc Detail code dddd RANK number of the data that could not be read eee e Bsl file...

Page 182: ...r code cccccccc Detail code ddd d Bsl file name Measures Check the Bsl file and the file system remove the cause of the error and restart the iSM server iSM09108 Bsl file re created illegal format detected detcode aaaaaaaa Classification NOTICE Explanation The Bsl file format was illegal when the iSM server was previously operated and the Bsl file was re created aaaaaaaa Detail code Measures Unnec...

Page 183: ...planation It indicates that it failed to initialize communication function to iSM server aaa Code indicating location of error bbb b Error code Measures Check whether abnormalities have occurred in the configuring process on the iSM server machine and restart the iSM server iSM10020 sys error main sc aaa h ec bbb b h Classification ERROR Explanation It indicates that it failed in system call at th...

Page 184: ...c aaa h ec bbb b h Classification NOTICE Explanation It indicates that it failed to initialize communication function to iSM server aaa Code indicating location of error bbb b Error code Measures Check whether abnormalities have occurred in the configuring process on the iSM server machine and restart the iSM server iSM10101 comm error Agent sc aaa h ec bbb b h Classification NOTICE Explanation It...

Page 185: ...tion ERROR Explanation It indicates that it failed in system call when telegram sending receiving from disk array aaa Code indicating location of error bbb b Error code Measures Check whether abnormalities such as insufficient memory have occurred in the operation environment of iSM server iSM10104 func error Agent sc aaa h ec bbb b h Classification NOTICE Explanation It indicates that it failed t...

Page 186: ...ailed to process the telegram receiving aaa Code indicating location of error bbb b Error code Measures Check whether abnormalities have occurred in the configuring process on the iSM server machine and restart the iSM server iSM10201 comm error client sc aaa h ec bbb b h Classification NOTICE Explanation It indicates that it failed to process the telegram transmission aaa Code indicating location...

Page 187: ...ment between iSM server and iSM client and connect again If there is no abnormality in the connection environment the iSM client may be one with old version Perform the version up of the iSM client and connect again iSM10220 sys error client sc aaa h ec bbb b h Classification ERROR Explanation It indicates that it failed in system call when telegram sending receiving aaa Code indicating location o...

Page 188: ...Function Guide Measures Check whether the configuration of disk array has been changed iSM10303 command aaa a volume bbbb h ccc c status failed dd h ee h ff h Classification INFO Explanation It indicates that it failed in accessing the volume expressed in volume number failure of SCSI protocol aaa a Command name bbbb Volume number ccc c Disk array name dd Sense Key defined in SCSI specification ee...

Page 189: ...fication hh Additional Sense Code Qualifier defined in SCSI specification As for command name refer to the NEC Storage Manager Data Replication User s Manual Function Guide Measures Check whether the configuration of disk array has been changed iSM10305 command aaa a bbb b status failed ec ccc c Classification INFO Explanation It indicates that it failed in accessing the disk array failure except ...

Page 190: ...Guide Measures Check whether the configuration of disk array has been changed iSM10307 command aaa a bbb b ccc c dddd h eee e status failed ec fff f Classification INFO Explanation It indicates that it failed in accessing the volume expressed in logical disk name failure of something except for SCSI protocol aaa a Command name bbb b Volume classification ccc c Logical disk name dddd Volume number ...

Page 191: ...I specification As for command name refer to the NEC Storage Manager Data Replication User s Manual Function Guide Measures Check whether the configuration of disk array has been changed iSM10309 command aaa a mv bbb b cccc h ddd d rv bbb b cccc h ddd d status failed ec eee e Classification INFO Explanation It indicates that it failed in accessing the pair expressed in MV or RV failure except for ...

Page 192: ...l disk name dddd Volume number eee e Disk array name As for command name refer to the NEC Storage Manager Data Replication User s Manual Function Guide Measures Unnecessary iSM10311 command aaa a bbb b Classification NOTICE Explanation It indicates that setting operation to disk array has been executed aaa a Command name bbb b Disk array name As for command name refer to the NEC Storage Manager Da...

Page 193: ...ry iSM10313 Replication state of diskarray was changed aaa a Replication Subsystem State bbb b Back Ground Copy Level c several states changed Classification NOTICE Explanation It indicates that the state change of disk array replication freeze defreeze was detected If two or more state transitions occurred within a polling interval and the midway states could not be identified several states chan...

Page 194: ... transitions occurred aaa a Logical disk name bbbb Volume number ccc c Disk array name Measures Unnecessary iSM10315 Logical Disks were unpaired mv aaa a bbbb h ccc c rv aaa a bbbb h ccc c several states changed Classification NOTICE Explanation It indicates that unpairing of paired volumes was detected If two or more state transitions occurred within a polling interval and the midway states could...

Page 195: ...nd the two are under the same state only one state is indicated for activity state sync state and copy control state aaa a Logical disk name bbbb Volume number ccc c Disk array name ddd d Activity state replicate Replicate separate Separate restore Restore restore protect Restore with RV protection eee e Sync state rpl exec Replicate Execution rpl exec rpl sync Sync State rpl sync cancel Forced Se...

Page 196: ... and restart the iSM server iSM10330 inconsistency of product revision of diskarray mv aaa a rv aaa a Classification NOTICE Explanation There is a functionally unacceptable difference in the product revisions between the disk arrays of MV and RV It indicates that the process has been aborted because replicate and restore will result in the inconsistency of the signatures on the disks aaa a Disk ar...

Page 197: ...ion Guide for Windows iSM10401 copy error mv aaa a bbbb h ccc c rv aaa a bbbb h ccc c status ddd d h UC eeeeeeee FC ff Classification ERROR Explanation It indicates the information of volume in which copy fault occurred aaa a Logical disk name bbbb Volume number ccc c Disk array name ddd d Error code 4 fault separation 9 abnormal suspend eeeeeeee ff Maintenance information Measures After remove ca...

Page 198: ...s Manual Installation and Operation Guide for Windows iSM10403 Disk array info aaa a S N bbb b Product ID ccc c UC dddddddd FC ee Classification ERROR Explanation It indicates additional information of disk array in which copy fault occurred For the pair composed by RemoteDataReplication additional information of disk array of each of MV and RV is output aaa a Disk array name bbb b Production numb...

Page 199: ...assification NOTICE Explanation It indicates that it failed in receiving telegram from iSM server aaaaaaaa Telegram code which indicates the telegram that occurred abnormality bbb b Error code Measures Check whether abnormalities have occurred in the configuring process on the iSM server iSM10420 comm error report sc aaa h ec bbb b h Classification NOTICE Explanation It indicates that it failed in...

Page 200: ...er iSM10440 func error report sc aaa h ec bbb b h Classification NOTICE Explanation It indicates that it failed in the transmission of trouble report to iSM client aaa Code indicating location of error bbb b Error code Measures Check whether abnormalities have occurred in the configuring process on the iSM server iSM10900 Process is busy when it terminates emergency Unexpected error message maybe ...

Page 201: ...ified parameter aaa a Classification INFO Explanation Setting of the disk array is executed according to the specified parameter aaa a Additional information Measures Unnecessary iSM11102 Specified Disk Array Subsystem is not monitored fault maintenance Classification INFO Explanation Specified disk array is not being monitored fault maintenance Measures Execute again after fault recovery or after...

Page 202: ... monitoring disk array and execute it again iSM11104 Disk Array Subsystem aaa a was selected Classification INFO Explanation The Disk Array aaa a has been selected aaa a Disk array name Measures Unnecessary iSM11105 Specified Disk Array Subsystem is set by another maintenance tool Classification INFO Explanation Specified disk array is set by another maintenance tool Measures Execute it again afte...

Page 203: ...as notified to the disk array Measures Unnecessary iSM11107 The end of the configuration operation was notified to disk array Classification INFO Explanation The end of configuration operation was notified to the disk array Measures Unnecessary iSM11108 aaa a was started Classification INFO Explanation aaa a iSMconf iSMautobind was started aaa a Program name Measures Unnecessary ...

Page 204: ...art of information about disk array Measures Check the status of the disk array iSM11151 Failed to get information or set configuration aaa a Classification INFO Explanation It failed in getting information or in setting configuration of the disk array aaa a Additional information Measures Check whether the disk array is a monitoring object of iSM iSM11152 Failed to output Log Message Classificati...

Page 205: ... failed in notifying the request for start of aaa a aaa a Program name Measures Check whether iSMsvr has started iSM11155 Failed to request notification for termination of aaa a Classification INFO Explanation It failed in notifying the request for end of aaa a aaa a Program name Measures Check whether iSMsvr has started iSM11161 Failed to get Disk Array Subsystem list Classification INFO Explanat...

Page 206: ...anager User s Manual iSM11163 Specified Disk Array Subsystem is not found Classification INFO Explanation The specified disk array cannot be found Measures Terminate the program Check that the iSM server covers the disk array as monitoring target and also check the environmental definition of the iSM server and the connection with the disk array For more information refer to Part III Operations of...

Page 207: ...SM11172 RANK doesn t exist Classification INFO Explanation RANK does not exist Measures Check the status of the disk array iSM11173 LD doesn t exist Classification INFO Explanation LD does not exist Measures Check the status of the disk array iSM11174 PD doesn t exist Classification INFO Explanation PD does not exist Measures Check the status of the disk array ...

Page 208: ...n t exist Classification INFO Explanation Port with access permission to LD does not exist Measures Check the status of the disk array iSM11178 LD Set doesn t exist Classification INFO Explanation There is no LD Set Measures Check the status of the disk array iSM11179 LD Set doesn t match Classification INFO Explanation LD Set does not match Measures Check the status of the disk array ...

Page 209: ... supports the information of the specified option iSM11181 WWPN does not exist Classification INFO Explanation WWPN does not exist Measures Check the status of the disk array iSM11220 Port aa h bb h was selected Classification INFO Explanation Port aa bb was selected aa bb Port number Measures Unnecessary iSM11221 View Host Permit List was selected Classification INFO Explanation View host permit ...

Page 210: ...231 Port configuration is required Classification INFO Explanation Port configuration is needed Measures Execute it after selecting the port iSM11232 Cannot set Access Control function Cross call function should be working for using Access Control function It is set up from the main menu Classification INFO Explanation Access Control function cannot be set Cross Call function must work when using ...

Page 211: ...d Measures Check the status of the disk array iSM11235 Effective LD without being in List Classification INFO Explanation A nonexistent logical disk was specified Measures Specify a logical disk that exists iSM11236 Setting over this ineffective Classification INFO Explanation Setting is invalid because the allowed number of assigned logical disks was exceeded Measures Reduce the number of assigne...

Page 212: ...this program iSM11240 PDG aa h was selected Classification INFO Explanation PDG aa was selected aa PDG number Measures Unnecessary iSM11241 Cannot set up LD because number of PD is not sufficient Classification INFO Explanation LD cannot be set because the number of PD is insufficient Measures Check the status of the disk array iSM11242 All settings are cleared Classification INFO Explanation All ...

Page 213: ... in the following message and go on the operation iSM11251 Failed to open a file Classification INFO Explanation It failed in opening a file Measures Check the content of the file iSM11252 Succeeded in loading a file Classification INFO Explanation It succeeded in loading a file Measures Unnecessary iSM11253 Illegal file parameter Classification INFO Explanation File parameter is invalid Measures ...

Page 214: ...ving a file Classification INFO Explanation It succeeded in saving a file Measures Unnecessary iSM11258 Failed to save a file Classification INFO Explanation It failed in saving a file Measures Check whether the specification of the file name and the save destination are correct iSM11300 This program configures Disk Array Subsystem Classification INFO Explanation This program configures disk array...

Page 215: ... from the host before executing this command which has the parameter of all or High Reliability Mode off Otherwise the data in LD may be invalid Measures Unnecessary iSM11306 ATTENTION Specified F W is older than Disk Array Subsystem s F W Classification INFO Explanation Attention Specified F W is older than F W of the disk array Measures Check whether F W file revision is correct iSM11307 ATTENTI...

Page 216: ... Classification INFO Explanation ATTENTION Internal Log data will be deleted Measures Unnecessary iSM11310 ATTENTION Media Error List data will be deleted Classification INFO Explanation Attention Media Error List data will be deleted Measures Unnecessary iSM11311 ATTENTION Need to reboot the OS to enable the setting Classification INFO Explanation Attention Rebooting the operation system is neede...

Page 217: ...necessary iSM11321 System space of 2MB is added to LD and LD is bound Classification INFO Explanation System space of 2MB is added to LD and LD is bound Measures Unnecessary iSM11322 The address which can be specified is aaaa h or bbbb h Classification INFO Explanation The address which can be specified is aaaa or bbbb aaaa bbbb Address which can be specified Measures Unnecessary ...

Page 218: ...NK iSM11330 Failed to get Disk Array Subsystem information Classification INFO Explanation It failed in getting the information of disk array Measures Check the status of the disk array iSM11340 Now downloading Please wait a minute Classification INFO Explanation Now downloading Wait a minute Measures Unnecessary iSM11360 Specified resource is not found Classification INFO Explanation Specified re...

Page 219: ... RANK Classification INFO Explanation It failed in binding RANK Measures Check the status of the disk array iSM11363 Failed to bind some RANKs Classification INFO Explanation It failed in binding some RANKs Measures Check the status of the disk array iSM11364 Failed to bind Hot Spare Classification INFO Explanation It failed in binding Hot Spare Measures Check the status of the disk array ...

Page 220: ... Specified RANK does not exist Measures Check the status of the disk array iSM11367 Specified Hot Spare doesn t exist Classification INFO Explanation Specified Hot spare does not exist Measures Check the status of the disk array iSM11369 Specified F W file is not conformable to the target Disk Array Classification INFO Explanation Specified F W file is not conformable to the object disk array Meas...

Page 221: ...hether it is the monitoring object of iSM iSM11373 Specified F W file is not conformable to the target resource F W Classification INFO Explanation Specified F W file is not conformable to the object resource Measures Check whether F W file is correct iSM11374 a RANKs were bound successfully But some RANKs failed to bind Classification INFO Explanation It succeeded to bind a number of RANKs but it...

Page 222: ... range that can be specified Classification INFO Explanation LD cannot be bound because number of LDs exceeds the range that can be specified Measures Input number of LD correctly iSM11377 Cannot bind LD because LD number exceeds the range that can be specified Only aa LDs will be able to be bound Classification INFO Explanation LD cannot be bound because number of LDs exceeds the range that can b...

Page 223: ...fication INFO Explanation Space to bind LD is insufficient Only aa number of LDs will be able to be bound aa Number of LD which can be bound Measures Check the space of RANK iSM11380 Failed to allocate a memory space Classification INFO Explanation It failed in allocating a memory space Measures Check the status of the server iSM11381 Failed to bind LD Classification INFO Explanation It failed in ...

Page 224: ...ures Check the status of RANK iSM11383 Succeeded in downloading of the following aaa a bbbb hex cc cc Classification INFO Explanation It succeeded in downloading of the following aaa a aaa a Download resource name bbbb Resource number cc cc Resource position Measures Unnecessary iSM11384 Failed to download F W of aaa a Classification INFO Explanation It failed in downloading aaa a aaa a Download r...

Page 225: ...easures Check the status of the disk array and download only the unexecuted one iSM11402 Auto assignment was selected aaa a Classification INFO Explanation Auto assignment was selected aaa a Additional information Measures Unnecessary iSM11403 Subsystem time specifying time was selected Classification INFO Explanation Subsystem time custom was selected Measures Unnecessary ...

Page 226: ...n SPARE cannot be bound by specified parameter aaa a Additional information Measures Check whether the input parameter is correct iSM11406 Cannot bind RANK by specified parameter aaa a Classification INFO Explanation RANK cannot be bound by specified parameter aaa a Additional information Measures Check whether the input parameter is correct iSM11407 LD format time was selected Classification INFO...

Page 227: ...a Classification INFO Explanation Cross call was selected aaa a Additional information Measures Unnecessary iSM11410 Subsystem control mode was selected aaa a Classification INFO Explanation Subsystem control mode was selected aaa a Additional information Measures Unnecessary iSM11412 Expand lun was selected aaa a Classification INFO Explanation Expand LUN was selected aaa a Additional information...

Page 228: ...tion Firmware file cannot be opened Measures Check whether the path and name of the firmware file is correct iSM11415 Illegal resource type was selected Classification INFO Explanation Selected resource is incorrect Measures Check whether the firmware file belongs to a target resource iSM11416 Firmware download was selected aaa a Classification INFO Explanation Firmware download was selected aaa a...

Page 229: ...planation Object disk array specified by firmware file is not found Measures Check whether the firmware file belongs to a target disk array iSM11420 Cannot bind some RANKs that was specified aaa a Classification INFO Explanation Some RANKs that was specified cannot be bound aaa a Additional information Measures Check the status of the disk array iSM11421 Forced reduce rebuilding was selected aaa a...

Page 230: ...xplanation Hot spare bind custom was selected aaa a Additional information Measures Unnecessary iSM11424 Hot SPARE bind standard was selected aaa a Classification INFO Explanation Hot spare bind standard was selected aaa a Additional information Measures Unnecessary iSM11425 Hot SPARE unbind was selected aaa a Classification INFO Explanation Hot spare unbind was selected aaa a Additional informati...

Page 231: ...planation RANK is not found in the specified PDG aaa a Additional information Measures Check the status of the disk array iSM11431 Auto repair was selected aaa a Classification INFO Explanation Auto repair was selected aaa a Additional information Measures Unnecessary iSM11437 PD assigned as SPARE is not found aaa a Classification INFO Explanation PD assigned as SPARE is not found aaa a Additional...

Page 232: ...s Check whether the input parameter is correct iSM11439 LD ownership was selected aaa a Classification INFO Explanation LD ownership was selected aaa a Additional information Measures Unnecessary iSM11440 Dynamic capacity expansion was selected aaa a Classification INFO Explanation Dynamic capacity expansion was selected aaa a Additional information Measures Unnecessary ...

Page 233: ...rd was selected aaa a Classification INFO Explanation RANK bind standard was selected aaa a Additional information Measures Unnecessary iSM11444 RANK unbind was selected aaa a Classification INFO Explanation RANK unbind was selected aaa a Additional information Measures Unnecessary iSM11455 Temp sense interval was selected Classification INFO Explanation Temp sense interval was selected Measures U...

Page 234: ...s downloaded to may be not present aaa a Classification INFO Explanation The resource of downloading destination may be not mounted aaa a Additional information Measures Check the status of the disk array iSM11501 LD information was selected Classification INFO Explanation LD information was selected Measures Unnecessary iSM11502 LD No Name information was selected Classification INFO Explanation ...

Page 235: ...K PD information was selected Classification INFO Explanation RANK PD information was selected Measures Unnecessary iSM11505 PD information was selected Classification INFO Explanation PD information was selected Measures Unnecessary iSM11506 RANK map information was selected Classification INFO Explanation RANK map information was selected Measures Unnecessary ...

Page 236: ...was selected Classification INFO Explanation Median error list init was selected Measures Unnecessary iSM11509 Subsystem view current setting was selected Classification INFO Explanation Subsystem view current setting was selected Measures Unnecessary iSM11510 Maintenance view current setting was selected Classification INFO Explanation Maintenance view current setting was selected Measures Unnece...

Page 237: ...ror List does not exist Measures Unnecessary iSM11531 Disk Array Subsystem list information option was selected Classification INFO Explanation Disk Array Subsystem list information option was selected Measures Unnecessary iSM11532 Disk Array Subsystem detail information option was selected aaa a Classification INFO Explanation Disk Array Subsystem detail information option was selected aaa a Addi...

Page 238: ...on Measures Unnecessary iSM11534 LD detail information option was selected aaa a Classification INFO Explanation LD detail information option was selected aaa a Additional information Measures Unnecessary iSM11535 PD list information option was selected aaa a Classification INFO Explanation PD list information option was selected aaa a Additional information Measures Unnecessary ...

Page 239: ...necessary iSM11537 Port information with LD key option was selected aaa a Classification INFO Explanation Port information with LD key option was selected aaa a Additional information Measures Unnecessary iSM11538 LD information with port key option was selected aaa a Classification INFO Explanation LD information with port key option was selected aaa a Additional information Measures Unnecessary ...

Page 240: ...information Measures Unnecessary iSM11540 Enclosure information option was selected aaa a Classification INFO Explanation Enclosure information option was selected aaa a Additional information Measures Unnecessary iSM11541 Controller resource doesn t exist aaa a Classification INFO Explanation Controller resource doesn t exist aaa a Additional information Measures Unnecessary ...

Page 241: ...lected aaa a Classification INFO Explanation Platform information option was selected aaa a Additional information Measures Unnecessary iSM11544 Specified Resource does not exist Classification INFO Explanation Specified resource does not exist Measures Check input resource name and resource number and retry processing iSM11545 Cache doesn t exist Classification INFO Explanation Cache module does ...

Page 242: ...M11549 Cannot make or refresh volume list data Classification ERROR Explanation Creation of a volume list data failed This message is output on UNIX system Measures If operation trace data has been collected troubleshoot on the basis of operation trace data and error code and then remove cause of fault iSM11557 Only root can use this option Classification ERROR Explanation A command was executed b...

Page 243: ...Classification INFO Explanation Spare Rebuild option was selected aaa a Additional information Measures Unnecessary iSM11563 iSMrepair was executed Classification INFO Explanation iSMrepair was executed Measures Unnecessary iSM11564 PD group number exceeds the range that can be specified Classification INFO Explanation PD Group number exceeds the range that can be specified Measures Check whether ...

Page 244: ...e range that can be specified Classification INFO Explanation RANK number exceeds the range that can be specified Measures Check whether the input parameter is correct iSM11567 PD Group Number is different Classification INFO Explanation PD Group Number is different Measures Check whether the input parameter is correct iSM11572 All information option was selected Classification INFO Explanation Al...

Page 245: ...Measures Unnecessary iSM11574 Enclosure detail information option is selected aaa a Classification INFO Explanation Enclosure detail information option was selected aaa a Additional information Measures Unnecessary iSM11575 LD Set detail information option was selected aaa a Classification INFO Explanation LD Set detail information option was selected aaa a Additional information Measures Unnecess...

Page 246: ...O Explanation It failed to communicate Measures Check whether iSMsvr has started iSM11602 Failed to set Log output environment Classification INFO Explanation It failed in setting Log output environment Measures Unnecessary iSM11603 Only an Administrators group can execute Classification INFO Explanation Execution is allowed for users belonging to Administrators group only This message is output o...

Page 247: ...sfully created This message is output on Windows system Measures Unnecessary iSM11702 Failed to make volume list data Classification ERROR Explanation It indicates that the volume list is not created This message is output on Windows system Measures A detailed error message is displayed Execute the correct operation according to the detailed error message iSM11703 Option is insufficient Classifica...

Page 248: ...specified option is not supported by the program This message is output on Windows system Measures Specify the correct option iSM11706 Too many options are specified Classification ERROR Explanation It indicates that two or more options are specified at a time This message is output on Windows system Measures Specify the correct option iSM11707 Combination of options is illegal Classification ERRO...

Page 249: ...pecify the correct parameter iSM11710 Conflict of volume list data has been detected Please update volume list data Classification ERROR Explanation Inconsistency was found in volume list Volume list is old and is not consistent with system status Measures Update the volume list iSM11721 Disk Array does not exist in volume list data Classification ERROR Explanation It indicates that the disk array...

Page 250: ...3 Specified ld_number does not exist in volume list data Classification ERROR Explanation It indicates that the specified logical disk is not registered in the volume disk This message is output on Windows system Measures Specify the correct logical disk iSM11724 Specified ld_name does not exist in volume list data Classification ERROR Explanation It indicates that the specified logical disk name ...

Page 251: ... iSM11726 Specified disk_number does not exist in volume list data Classification ERROR Explanation It indicates that the specified disk is not registered in the volume list This message is output on Windows system Measures Specify the correct disk iSM11727 Specified HBT does not exist in volume list data Classification ERROR Explanation It indicates that the specified HBT is not registered in the...

Page 252: ...Classification ERROR Explanation It indicates that the disk array information is not registered in the volume list This message is output on Windows system Measures Check the connection between the host machine and the disk array and newly create a volume list iSM11730 Failed to get the specified Disk Array information Classification ERROR Explanation It indicates that the disk array information c...

Page 253: ...mount point volume is not registered in the volume list This message is output on Windows system Measures Specify the correct mount point volume name iSM11733 Failed to initialize an ODM session Classification ERROR Explanation Failed in initialization of ODM session Measures Check that ODM environment is normal and retry processing Check that system memory capacity is sufficient and retry process...

Page 254: ... Measures Target control volume list data may become invalid Create a target control volume list again iSM11737 Failed to get control volume definitions Classification ERROR Explanation Failed in obtaining control volume definitions Measures Check that control volume definition file is described correctly and then retry processing iSM11738 Failed to get target volume definitions Classification ERR...

Page 255: ... volume definition file Measures Check that target volume definition file exists and then retry processing iSM11744 Failed to open target control volume list data Classification ERROR Explanation Failed in opening target control volume list Measures Target control volume list data may be invalid Create a target control volume list again iSM11745 Failed to close control volume definition file Class...

Page 256: ... closing target control volume list Measures Target control volume list data may be invalid Create a target control volume list again iSM11748 Target control volume list data has invalid data Classification ERROR Explanation Target control volume list includes invalid data Measures Create a target control volume list again iSM11749 Control volume is not found Classification ERROR Explanation Contr...

Page 257: ...y started iSM11751 iSMvollist command has already started iSM11751 iSMmknod command has already started iSM11751 iSM Server has already started Classification ERROR Explanation Reference or update of Volume List was executed during execution of the replication control command The volume list is being updated by the iSMvollist command Update of Volume List was executed during execution of the iSMmk...

Page 258: ...remove it iSM11756 Illegal OS version Classification ERROR Explanation This version of OS is not supported for NEC Storage ReplicationControl This message is output on Windows system Measures NEC Storage ReplicationControl cannot be used iSM11757 SCSI path through driver is not installed Classification ERROR Explanation The SCSI path through driver is not installed in the system This message is ou...

Page 259: ...ail 211 mknod command fail 212 mksf command fail 213 child process dissipation 214 scsi open fail 215 scsi inquiry fail 216 scsi sense fail 230 open fail 231 stat fail Measures If the operation trace is collected use the information in the operation trace and the error code to find the cause and remove it iSM11759 Failed to open control volume in Diagnostic mode Classification ERROR Explanation Co...

Page 260: ...ge is output on Windows system Measures The volume list may be invalid Create a new volume list iSM11782 Failed to close volume list data Classification ERROR Explanation It indicates that the volume list is not closed due to an error This message is output on Windows system Measures The volume list may be invalid Create a new volume list iSM11783 Failed to read volume list data Classification ERR...

Page 261: ... failed This message is output on Windows system Measures The volume list may be invalid Create a new volume list iSM11786 Failed to copy volume list data Classification ERROR Explanation It indicates that the volume list is not copied due to an error This message is output on Windows system Measures The volume list may be invalid Create a new volume list iSM11787 Failed to rename volume list data...

Page 262: ...ROR Explanation It indicates that directory creation is failed This message is output on Windows system Measures Volume list table is created under the installation directory of an OS Identify a cause of inability to create a directory and then create a volume list table again iSM11793 Failed to query device Classification ERROR Explanation It indicates that device query is failed This message is ...

Page 263: ... not supported by the OS you currently use Use the OS supporting this program to run this program iSM11796 Failed to allocate a memory space Classification ERROR Explanation It indicates that the required memory space cannot be allocated Measures The required memory space may be insufficient Allocate a required memory space by expanding memory to run this program iSM11797 Target device does not ex...

Page 264: ... to create log files Classification INFO Explanation Failed in creating log file Measures Check that creation of file is allowed in the log file output directory iSM11802 Started to get aaa a log Classification INFO Explanation Obtaining log from disk array indicated by aaa a started aaa a Disk array name Measures Unnecessary iSM11803 Succeed to get aaa a log Classification INFO Explanation Obtain...

Page 265: ...sage List 260 iSM11804 Failed to get aaa a log Classification INFO Explanation Failed in obtaining log from disk array indicated by aaa a Measures Check status of iSM server and disk array and then retry processing ...

Page 266: ...ication INFO Explanation Replication command start message Only when specifying wait aaaa bb cc Year Month Day dd ee ff Hour Minute Second ggg g Volume name Measures Unnecessary iSM13202 Replicate Normal End aaaa bb cc dd ee ff MV ggg g RV ggg g Classification INFO Explanation Replication command end message Only when specifying wait aaaa bb cc Year Month Day dd ee ff Hour Minute Second ggg g Volu...

Page 267: ...immediately before to handle it iSM13204 Restore Start aaaa bb cc dd ee ff MV ggg g RV ggg g Classification INFO Explanation Restoration command start message aaaa bb cc Year Month Day dd ee ff Hour Minute Second ggg g Volume name Measures Unnecessary iSM13205 Restore Normal End aaaa bb cc dd ee ff MV ggg g RV ggg g Classification INFO Explanation Restoration command normal termination message Onl...

Page 268: ...mmediately before to handle it iSM13207 Separate Start aaaa bb cc dd ee ff MV ggg g RV ggg g Classification INFO Explanation Separation command start message aaaa bb cc Year Month Day dd ee ff Hour Minute Second ggg g Volume name Measures Unnecessary iSM13208 Separate Normal End aaaa bb cc dd ee ff MV ggg g RV ggg g Classification INFO Explanation Separation command normal termination message Only...

Page 269: ...mmediately before to handle it iSM13210 Change Start aaaa bb cc dd ee ff MV ggg g RV ggg g Classification INFO Explanation Copy Control State change command start message aaaa bb cc Year Month Day dd ee ff Hour Minute Second ggg g Volume name Measures Unnecessary iSM13211 Change Normal End aaaa bb cc dd ee ff MV ggg g RV ggg g Classification INFO Explanation Copy Control State change command norma...

Page 270: ...ately before to handle it iSM13213 Wait Abnormal End aaaa bb cc dd ee ff MV ggg g RV ggg g Classification INFO Explanation The wait by the wait state command has abnormally terminated aaaa bb cc Year Month Day dd ee ff Hour Minute Second ggg g Volume name Measures Check the message displayed immediately before to handle it iSM13214 These targets have already replicated MV aaa a RV aaa a Classifica...

Page 271: ...ation bbb b Volume name Measures Unnecessary iSM13216 These targets have already restored MV aaa a RV aaa a Classification INFO Explanation Specified volume has already been restored aaa a Volume name Measures Unnecessary iSM13220 Setting drive letter aaa a has succeeded iSM13220 Setting mount point bbb b has succeeded Classification INFO Explanation The drive letter or the NTFS folder mount point...

Page 272: ... name bbb b Path Measures Unnecessary iSM13222 Reading signature succeeded aaa a records Classification INFO Explanation The disk signature information was read successfully This message is output on Windows system aaa a Record count Measures Unnecessary iSM13223 Initializing signature succeeded volume aaa a Classification INFO Explanation The disk signature information was initialized successfull...

Page 273: ...n Start Classification INFO Explanation Indicates a start message of device scanning command Measures Unnecessary iSM13229 Scan Normal End Classification INFO Explanation Indicates a normal termination message of device scanning command Measures Unnecessary iSM13230 Scan Abnormal End Classification INFO Explanation Indicates an abnormal termination message of device scanning command Measures Take ...

Page 274: ...map file succeeded volume aaa a Classification INFO Explanation The signature information of the specified disk was deleted from the signature map file successfully This message is output on Windows system aaa a Physical disk number Measures Unnecessary iSM13233 Deleting of signature information from signature map file has succeeded Classification INFO Explanation All the disk signature informatio...

Page 275: ...Measures Unnecessary iSM13235 Importing file succeeded aaa a records Classification INFO Explanation The disk signature information was read successfully This message is output on Windows system aaa a Record count Measures Unnecessary iSM13240 SnapshotBackup Start aaaa bb cc dd ee ff Classification INFO Explanation Backup of snapshot has started aaaa bb cc Year Month Day dd ee ff Hour Minute Secon...

Page 276: ... Abnormal End aaaa bb cc dd ee ff Classification INFO Explanation Backup of snapshot has terminated abnormally aaaa bb cc Year Month Day dd ee ff Hour Minute Second Measures Take measures with reference to a message that was output immediately before this message iSM13243 SnapshotRestore Start aaaa bb cc dd ee ff Classification INFO Explanation Restoration of snapshot has started aaaa bb cc Year M...

Page 277: ...ecessary iSM13245 SnapshotRestore Abnormal End aaaa bb cc dd ee ff Classification INFO Explanation Restoration of snapshot has terminated abnormally aaaa bb cc Year Month Day dd ee ff Hour Minute Second Measures Take measures with reference to a message that was output immediately before this message iSM13247 Command has completed successfully Classification INFO Explanation Command execution was ...

Page 278: ...NG Explanation Specified pair information is defined repeatedly When iSMrc_sense is executed the volume defined on the MV side is repeated aaa a Volume name Measures Revise the file The processing continues iSM13406 Specified targets are duplicated MV aaa a Classification WARNING Explanation MV specified by omitting the RV is defined repeatedly When iSMrc_sense is executed the volume defined on th...

Page 279: ... have replicated MV aaa a RV aaa a Classification WARNING Explanation A command which must not be executed for volumes with Replicate being completed was executed aaa a Volume name Measures Confirm the condition for executing the specified command and then re execute the command iSM13409 These targets have separated MV aaa a RV aaa a Classification WARNING Explanation A command which must not be e...

Page 280: ...pended Classification WARNING Explanation The specified pair of volumes are in normal suspend state of copy control states Measures Execute the copy mode change instruction to restart the process by issuing the copy control state change command iSM13412 Target pair s copy mode is background Classification WARNING Explanation The specified pair of volumes are in background copy state of copy contro...

Page 281: ...n change the copy mode iSM13414 Conflict of volume list data has been detected Please update volume list data Classification WARNING Explanation Inconsistency was found in volume list Volume list is old and is not consistent with system status Measures Update the volume list iSM13415 Specified volume was ignored aaa a Classification WARNING Explanation Specified volume was ignored aaa a Ignored vo...

Page 282: ...d value Measures Specify the necessary arguments in the command line If file option is specified check the replication operation file iSM13501 Specified options are duplicated aaa a Classification ERROR Explanation The same argument is specified more than once in the command line aaa a Specified value Measures Specify only one argument iSM13502 Options which can not be omitted are specified aaa a ...

Page 283: ...anation An invalid combination of arguments are specified in the command line aaa a Specified value Measures Check the input format and enter it again iSM13505 Illegal control option Classification ERROR Explanation The argument you specified in the command line cannot be specified Measures Check the input format and enter it again iSM13506 Illegal mvflg type aaa a Classification ERROR Explanation...

Page 284: ...ROR Explanation The value specified in cprange is invalid aaa a Specified value Measures Specify a correct value iSM13509 Illegal cpmode type aaa a Classification ERROR Explanation The value specified in cpmode is invalid aaa a Specified value Measures Specify a correct value iSM13510 Illegal rvacc type aaa a Classification ERROR Explanation The value specified in rvacc for RV is invalid aaa a Spe...

Page 285: ...ecify a correct value iSM13513 Volume aaa a does not exist in volume list Classification ERROR Explanation The specified volume doesn t exist in the Volume Table may or may not be displayed aaa a Specified volume name Measures Check the volume and execute it again or re create the Volume Table iSM13514 Volume name is too long aaa a Classification ERROR Explanation The specified volume name is too ...

Page 286: ...t in the volume group or disk group This message is output on UNIX system Measures Specify only one volume for the RV iSM13517 Number of LD MV is not equal to that of LD RV Classification ERROR Explanation The number of volumes specified for MV and RV are different This message is output on UNIX system Measures Make the number of MV and RV volumes equal iSM13518 Illegal value of wait second aaa a ...

Page 287: ...a Classification ERROR Explanation The value specified in the environment variable RPL_ENDWATCHDEV is invalid The value specified in RPL_ENDWATCHDEV of the replication operation option setting file is not allowed aaa a Specified volume Measures Specify a value within the specified range iSM13521 Specified volume group does not exist vg aaa a iSM13521 Specified disk group does not exist dg bbb b Cl...

Page 288: ...tion ERROR Explanation The specified pair is invalid Measures Specify a correct pair iSM13524 No such file filename aaa a errno bbb Classification ERROR Explanation The specified file doesn t exist aaa a File name bbb Error number Measures Specify a correct file name iSM13525 Illegal file type filename aaa a Classification ERROR Explanation The specified file type cannot be processed aaa a File na...

Page 289: ...aracter is included filename aaa a line bbb b Classification ERROR Explanation The first column of the file contains a space aaa a File name bbb b Number of column Measures Correct the file and execute it again iSM13528 Line has too many characters filename aaa a line bbb b Classification ERROR Explanation More than 1024 characters are specified in one line aaa a File name bbb b Number of column M...

Page 290: ...3532 Illegal RV type is specified filename aaa a line bbb b Classification ERROR Explanation An invalid value was specified in RV Type aaa a File name bbb b Number of column Measures Specify correct value for RV Type iSM13533 MV name is too long error filename aaa a line bbb b Classification ERROR Explanation The volume name specified for MV is too long aaa a File name bbb b Number of column Measu...

Page 291: ...ror is detected in the execution of fgets function File read out is interrupted since failed to obtain volume group or disk group information aaa a File name bbb b Number of column Measures Check that the file is not destroyed and retry the command Or Specify a correct volume group or disk group iSM13537 Number of LD MV is not equal to that of LD RV filename aaa a line bbb b Classification ERROR E...

Page 292: ...nation force all or rv cannot be specified when RV is not visible from the self host Measures Specify mv when RV is not visible from the self host iSM13540 Illegal volflg type aaa a Classification ERROR Explanation The value specified in the vol type is invalid aaa a Specified value Measures Specify a correct value iSM13541 Semi sync mode is not available to DynamicDataReplication Classification E...

Page 293: ...on Specified partition does not exist This message is output on Windows system Measures Check the specified partition and retry it iSM13548 Making MV RV device list failed Classification ERROR Explanation Creation of internal information of the specified volume failed Measures Check the message displayed immediately before to handle it iSM13549 Failed to replicate Classification ERROR Explanation ...

Page 294: ...the message displayed immediately before to handle it iSM13552 Failed to change Classification ERROR Explanation Change Copy Control State failed Measures Check the message displayed immediately before to handle it iSM13555 Checking status failed detail error code aaa Classification ERROR Explanation Could not obtain volume state during wait mode process aaa Error code Measures Take appropriate me...

Page 295: ...as failed Classification ERROR Explanation SCSI open error occurred Measures Check that the user with the access right to the volume exists or that the disk number corresponding to the specified volume exists and execute it again iSM13558 SCSI close has failed Classification ERROR Explanation SCSI close error occurred Measures Check that the user with the access right to the volume exists or that ...

Page 296: ...fy RV and execute it again iSM13563 System call error error code aaa Classification ERROR Explanation It failed in system calling aaa Error number Measures If the operation trace is collected use the information in the operation trace and the error code to find the cause and remove it iSM13564 This connection does not allow replicating restoring at the same time Classification ERROR Explanation Si...

Page 297: ... The activity state of the pair of the specified RV and the paired RV is not Separate Measures Execute it when the pair activity state with RV becomes Separate iSM13567 Specified disk array s status is freeze Classification ERROR Explanation The disk array where the specified MV and RV are stored is in the Freeze state Measures Cancel the Freeze state and execute it again iSM13569 Target pair is r...

Page 298: ...being separated Measures After Separate is complete resume the process iSM13573 Target pair is not replicated or restored Classification ERROR Explanation The activity state of the specified pair is not the Replicate or Restore state Measures Execute it again when the activity state is the Replicate or Restore state iSM13574 Specified path aaa a does not exist Classification ERROR Explanation Spec...

Page 299: ...red Classification ERROR Explanation Specified volume is not paired Or it failed to obtain the pair main activity status information Measures Retry after confirming the pair state of the specified volume iSM13577 These targets are replicating now MV aaa a RV aaa a Classification ERROR Explanation A non executable replication operation command was performed for the pair in Replicate execution aaa a...

Page 300: ...n A non executable replication operation command was performed for the pair in Restore execution aaa a Volume name Measures Check the execution conditions of the specified command and execute it again iSM13581 These targets have replicated Classification ERROR Explanation A command not allowed for replicated volume was executed Measures Check executing condition of the command and retry command ex...

Page 301: ...cation ERROR Explanation Insufficient memory to execute the process and error number may or may not be displayed aaa a Resource name bbb Error number Measures Add more memory to the system iSM13585 Volume list is missing or unexpected error occurred error code aa Classification ERROR Explanation Processing is interrupted because the volume list table does not exist aa Error code 2 fopen failure 3 ...

Page 302: ...f the volume list table is not correct Measures Create a new volume list table iSM13592 Target pair is not separated Classification ERROR Explanation The main active status of the specified pair is not Separate Measures Execute it when the pair activity state becomes Separate iSM13595 License for DynamicDataReplication is locked Classification ERROR Explanation The NEC Storage DynamicDataReplicati...

Page 303: ...7 DynamicDataReplication is not supported Classification ERROR Explanation The DynamicDataReplication function is not supported Measures NEC Storage ReplicationControl cannot be used iSM13598 RemoteDataReplication is not supported Classification ERROR Explanation The RemoteDataReplication function is not supported Measures NEC Storage ReplicationControl cannot be used iSM13599 License for this com...

Page 304: ...tion operation option setting file iSMrpl ini must be changed to execute operation for multiple partitions However operation for multiple extensions is not allowed iSM13601 Specified drive is not basic disk Classification ERROR Explanation Specified drive is not a basic disk This message is output on Windows system Measures Specify a basic disk and retry it iSM13602 Specified partitions is not pri...

Page 305: ...nagement in case of Windows 2000 Settings for the replication operation option setting file iSMrpl ini must be changed to execute operation for multiple partitions However operation for multiple extensions is not allowed iSM13604 Specified partition does not exist Classification ERROR Explanation Specified partition does not exist This message is output on Windows system Measures Check the partiti...

Page 306: ...partition has already been mounted This message is output on Windows system Measures Check the specified partition and re execute iSM13609 Access of specified disk was refused Classification ERROR Explanation Access to the disk is refused This message is output on Windows system Measures If there is any application accessing the specified disk terminate the application and then re execute Refer to...

Page 307: ...lassification ERROR Explanation The signature information of the specified disk does not exist This message is output on Windows system aaa a Physical disk number Measures Specify a correct value iSM13614 Failed to read signature volume aaa a Classification ERROR Explanation The disk signature information could not be read This message is output on Windows system aaa a Physical disk number Measure...

Page 308: ...t exist in signature map file volume aaa a Classification ERROR Explanation The specified disk does not exist in the signature map file This message is output on Windows system aaa a Physical disk number Measures Specify a correct value iSM13619 Writing signature failed volume aaa a Classification ERROR Explanation The signature could not be written into the signature map file This message is outp...

Page 309: ...message iSM13626 Signature file format is illegal filename aaa a Classification ERROR Explanation The signature map file is in illegal format This message is output on Windows system aaa a File name Measures Specify a correct signature map file iSM13627 Specified volume s signature does not exist in file filename aaa a Classification ERROR Explanation The signature information of the specified dis...

Page 310: ...ecified disk is read only Write operation is not executes This message is output on Windows system Measures Change the RV access from the Replication Manager or select a read write enable disk iSM13631 Failed to mount Classification ERROR Explanation Failed to mount This message is output on Windows system Measures Check the message displayed immediately before to handle it iSM13632 Failed to umou...

Page 311: ... drive letter or the NTFS folder mount point could not be set This message is output on Windows system aaa a Drive letter bbb b Path Measures Take measures according to the message output immediately before this message iSM13635 Failed to reset drive letter aaa a iSM13635 Failed to reset mount point bbb b Classification ERROR Explanation The drive letter or the NTFS folder mount point could not be...

Page 312: ...his message iSM13637 Specified path aaa a is not correct directory Classification ERROR Explanation Mount point does not reside in the specified NTFS directory This message is output on Windows system aaa a Path Measures Check the mount point and re execute iSM13638 This OS version does not support specified function Classification ERROR Explanation Specified option cannot be used on this OS This ...

Page 313: ...ssary for firmware are not supported aaa a Function name signature Signature function separate immediate Separate Quick Replicate function separate RDR immediate Separate Quick Replicate function of RemoteDataReplication restore rv protection Restore protect function Measures Check for the target product and update it iSM13642 Popen ps command has failed Classification ERROR Explanation The I O fu...

Page 314: ...M13646 Specified mv volume is mounted path aaa a Classification ERROR Explanation The MV has been mounted This message is output on UNIX system aaa a Path name Measures Unmount the MV and then re execute the command iSM13647 These targets are not replicating now MV aaa a RV aaa a Classification ERROR Explanation Specified pair is not in the replication status aaa a Volume name Measures Check the p...

Page 315: ...OR Explanation Specified pair is not in the restoration status aaa a Volume name Measures Check the specified pair operation status and re execute iSM13653 Illegal mode type aaa a Classification ERROR Explanation The value specified in the mode option of the Restore command is illegal aaa a Specified value Measures Specify a correct value iSM13654 Illegal rvuse type aaa a Classification ERROR Expl...

Page 316: ...value iSM13656 Illegal value of interval second aaa a Classification ERROR Explanation The value specified in the interval option of the Wait command is illegal aaa a Specified value Measures Specify a correct value iSM13657 Illegal value of limit second aaa a Classification ERROR Explanation The value specified in the limit option of the Wait command is illegal aaa a Specified value Measures Spec...

Page 317: ...fication ERROR Explanation The specified volumes can not be operated Measures The volume is specified under the NotReady status Check status of volume and retry command execution iSM13660 Replicate command has terminated because activity status is changed by other process Classification ERROR Explanation Main activity status of a pair has been change by other process during waiting process for com...

Page 318: ...atus of a pair has been changed by other process during waiting process for completion of separation The separate command has terminated waiting for completion of separation Measures Check status of pair If separation is required retry executing the separate command iSM13663 The processing of waiting has terminated because separate diff or copy diff does not decrease in the specified time aaa sec ...

Page 319: ...n execution of a command the specified user ID and password are used for connecting to Microsoft SQL Server 2000 However if a user ID is omitted user name and password of Windows login account are used for connection Check that the user ID and password are correct and then retry command execution iSM13679 Illegal remod type aaa a Classification ERROR Explanation A value specified for remod option ...

Page 320: ...s available in given environment and then retry command execution iSM13683 No authority to access database Classification ERROR Explanation No authority to access database is given Measures Check that authority to access database is given Check that database is not under restoration or under verification iSM13684 Failed to get database name list Classification ERROR Explanation Failed in obtaining...

Page 321: ...ailed in creating metafile aaa a File name Measures Check that specified metafile is correct and retry command execution iSM13687 Metafile aaa a is not found Classification ERROR Explanation Specified metafile is not found aaa a File name Measures Check that specified metafile is correct and retry command execution iSM13688 Failed to metafile aaa a open Classification ERROR Explanation Failed in o...

Page 322: ...o SQL command execution Classification ERROR Explanation Failed in SQL command Measures Check error log of Microsoft SQL Server 2000 remove cause of fault and then retry command execution iSM13691 Dbname does not exist in SQL server Classification ERROR Explanation Database name does not exist in Microsoft SQL Server 2000 Measures Check that database name is correct and then retry command executio...

Page 323: ...ROR Explanation Database is used by other process aaa a Database name Measures Check that other process is not using the database and then retry command execution iSM13695 Failed to detach database Classification ERROR Explanation Detaching database failed Measures Check that detaching database is allowed and then retry command execution iSM13696 Failed to get database volume from metafile Classif...

Page 324: ...ile of database and then retry command execution iSM13699 Number of move files are not equal to metafile s number Classification ERROR Explanation The number of files specified by move option is not the same as the number of files in database Measures Check that the number of specified files is the same as the number of physical files in database and then retry command execution iSM13700 Failed to...

Page 325: ... b Detailed information This code isn t disorder reason but a value for maintenance Measures For specifying R W check that the system is under separated status and then retry command execution iSM13702 Specified Background copy level is incorrect level aaa a code bbb b ccc c ccc c ccc c Classification ERROR Explanation Invalid value has been specified for copy level aaa a Specified values bbb b Pr...

Page 326: ... unexpected error occurred aaa a Process number bbb b Detailed information This code isn t disorder reason but a value for maintenance Measures Abnormality was found in message from iSM server Check status of iSM server iSM13705 Receive data is incorrect Data mismatch may has occurred in iSM Server code aaa a bbb b bbb b bbb b Classification ERROR Explanation Received data is invalid Data inconsis...

Page 327: ...bb b bbb b bbb b Classification ERROR Explanation Pair setting is unavailable because specified RV has been specified for a pair with other MV aaa a Process number bbb b Detailed information This code isn t disorder reason but a value for maintenance Measures Check status of specified RV and then specify pairs correctly iSM13708 Specified pair will build loop structure code aaa a bbb b bbb b bbb b...

Page 328: ...e aaa a bbb b bbb b bbb b Classification ERROR Explanation Pair setting is not allowed because volume capacities are different from each other aaa a Process number bbb b Detailed information This code isn t disorder reason but a value for maintenance Measures Check volume capacity iSM13711 OS type of specified volumes does not match code aaa a bbb b bbb b bbb b Classification ERROR Explanation OS ...

Page 329: ...a a bbb b bbb b bbb b Classification ERROR Explanation Specified disk array is not under control of iSM aaa a Process number bbb b Detailed information This code isn t disorder reason but a value for maintenance Measures Check that specified disk array is under management of iSM iSM13714 Disk Array includes specified volume is not managed by iSM code aaa a bbb b bbb b bbb b Classification ERROR Ex...

Page 330: ...under defreeze status aaa a Process number bbb b Detailed information This code isn t disorder reason but a value for maintenance Measures Check the status of the disk array iSM13717 Control path is not set to iSM Server code aaa a bbb b bbb b bbb b Classification ERROR Explanation I O path for disk array is not specified to use iSM server replication management function aaa a Process number bbb b...

Page 331: ...ion ERROR Explanation Specified disk array name is tool long aaa a Process number bbb b Detailed information This code isn t disorder reason but a value for maintenance Measures Input a correct disk array name and then retry command execution iSM13720 License for DynamicDataReplication RemoteDataReplication is locked code aaa a bbb b bbb b bbb b Classification ERROR Explanation License for NEC Sto...

Page 332: ...tailed information This code isn t disorder reason but a value for maintenance Measures Check supporting status of disk array iSM13722 Specified volume does not exist in Logical disk list code aaa a bbb b bbb b bbb b Classification ERROR Explanation Specified volume does not exist in logical disk list aaa a Process number bbb b Detailed information This code isn t disorder reason but a value for m...

Page 333: ...bbb b Detailed information This code isn t disorder reason but a value for maintenance Measures Start monitoring on disk array iSM13724 Failed to receive volume information code aaa a bbb b bbb b bbb b Classification ERROR Explanation Obtaining volume information failed aaa a Process number bbb b Detailed information This code isn t disorder reason but a value for maintenance Measures Check specif...

Page 334: ... bbb b Detailed information This code isn t disorder reason but a value for maintenance Measures Check that disk array is monitored or that data replication function is available iSM13726 Volume information error has detected in iSM server code aaa a bbb b bbb b bbb b Classification ERROR Explanation Volume information is invalid aaa a Process number bbb b Detailed information This code isn t diso...

Page 335: ... maintenance Measures Specified volume which has reserve attribute is not specifiable iSM13728 Failed to execute command part of targets Classification ERROR Explanation Operations on some pairs failed Measures Check status of pairs with failed operation and then retry command execution iSM13729 Failed to execute command all of targets Classification ERROR Explanation Operations on all pairs faile...

Page 336: ...ssification ERROR Explanation Specified volume does not allow pair setting aaa a Process number bbb b Detailed information This code isn t disorder reason but a value for maintenance Measures Check that operation is allowed for disk array of specified volume iSM13732 Capacity of DDR license is insufficient code aaa a bbb b bbb b bbb b Classification ERROR Explanation Licensed capacity of NEC Stora...

Page 337: ... Array as RV code aaa a bbb b bbb b bbb b Classification ERROR Explanation Specified MV has already been paired as RV within the same disk aaa a Process number bbb b Detailed information This code isn t disorder reason but a value for maintenance Measures Check status of specified MV and specify pairs correctly iSM13735 Specified RV has already paired with other volume on same Disk Array as MV cod...

Page 338: ...sing of target control list failed Measures A target control volume list may be invalid Create a target control volume list again iSM13738 Target control volume list data has invalid data Classification ERROR Explanation Target control list contains invalid information Measures Create a target control volume list again iSM13739 Control volume is not found Classification ERROR Explanation Control v...

Page 339: ...tion ERROR Explanation Socked creation failed aaa a Process number bbb b ccc c ddd d Detailed information This code isn t disorder reason but a value for maintenance Measures With reference to error number indicated by ddd d in detailed information remove cause of error and retry command execution iSM13742 Failed to send to iSM Server code aaa a bbb b bbb b bbb b Classification ERROR Explanation M...

Page 340: ...n This code isn t disorder reason but a value for maintenance Measures Check status of communication with iSM server iSM13744 Specified aaa a is duplicated code bbb b ccc c ccc c ccc c Classification ERROR Explanation Specified volume exists in duplication aaa a Volume number bbb b Process number ccc c Detailed information This code isn t disorder reason but a value for maintenance Measures Check ...

Page 341: ...e bbb b ccc c ccc c ccc c Classification ERROR Explanation Invalid OS type has been specified for volume aaa a OS type bbb b Process number ccc c Detailed information This code isn t disorder reason but a value for maintenance Measures Specify a correct OS type for volume iSM13747 Specified Disk Array does not have link information code aaa a bbb b bbb b bbb b Classification ERROR Explanation Link...

Page 342: ...nlocking bbb b Drive letter ccc c Mount point volume name Measures Take measures with reference to a message that was output immediately before this message iSM13749 Volume list data is locked by another process Classification ERROR Explanation Volume list data has been created modified by other process Measures After completion of a process retry command execution iSM13750 Volume list data does n...

Page 343: ...out occurred in process of iSM server Measures Loads on iSM server may be too heavy Check status of iSM server and retry command execution iSM13753 Disconnected from iSM Server Classification ERROR Explanation Connection with iSM server was disconnected Measures Operations of iSM server may have stopped Check status of iSM server iSM13754 Replication function of iSM Server is not ready Classificat...

Page 344: ...this message iSM13800 No such database name filename aaa a line bbb b Classification ERROR Explanation Database name has not been specified in database operation file aaa a File name bbb b Line number Measures Specify a database name iSM13801 Illegal Option type is specified filename aaa a line bbb b Classification ERROR Explanation Invalid value was specified for option type in database operation...

Page 345: ... byte iSM13803 User id is too long filename aaa a line bbb b Classification ERROR Explanation User ID specified in database operation file is too long aaa a File name bbb b Line number Measures Specify a user ID within 64 characters 1 byte iSM13804 Password is too long filename aaa a line bbb b Classification ERROR Explanation Password specified in database operation file is too long aaa a File na...

Page 346: ... 16 characters 1 byte iSM13808 Illegal remod type filename aaa a line bbb b Classification ERROR Explanation Database return mode value specified in database operation file is invalid aaa a File name bbb b Line number Measures Specify a correct value iSM13809 Refile name is too long filename aaa a line bbb b Classification ERROR Explanation Standby database file name specified in database operatio...

Page 347: ...ong filename aaa a line bbb b Classification ERROR Explanation Physical file name for move option specified in database operation file is too long aaa a File name bbb b Line number Measures Specify move option physical file name within 1024 characters 1 byte iSM13812 Illegal control option aaa a filename bbb b line ccc c Classification ERROR Explanation Option specified in database operation file ...

Page 348: ...egal combination of options input filename aaa a line bbb b Classification ERROR Explanation Option input has been specified in database operation file aaa a File name bbb b Line number Measures Do not specify input option when specifying uid and pass options iSM13815 Options uid can not be omitted are specified filename aaa a line bbb b Classification ERROR Explanation Option uid has been omitted...

Page 349: ...andby also when specifying refile option iSM13817 Specified database name is duplicated filename aaa a line bbb b Classification ERROR Explanation Specified database overlaps in database operation file aaa a File name bbb b Line number Measures Specify a database uniquely iSM13818 Failed to metafolder aaa a creation Classification ERROR Explanation Specified metadata storage folder cannot be creat...

Page 350: ...sification ERROR Explanation Value specified by server option is invalid aaa a Server name Measures Specify a name in a form of computer name instance name or computer name iSM13821 Illegal server name aaa a filename bbb b line ccc c Classification ERROR Explanation Value specified by server option is invalid aaa a Server name bbb b File name ccc c Line number Measures Specify a name in a form of ...

Page 351: ...13824 Illegal SQL server version Classification ERROR Explanation Version of Microsoft SQL Server 2000 is earlier than ServicePack2 Measures Install ServicePack2 of Microsoft SQL Server 2000 iSM13825 Failed to I O path route Classification ERROR Explanation Command execution is not allowed because linked operation with replication management via iSM server has been specified in I O issuing control...

Page 352: ...e iSM13827 User id is too long Classification ERROR Explanation User ID is too long Measures Specify user ID within 64 characters 1 byte iSM13828 Password is too long Classification ERROR Explanation Password is too long Measures Specify password within 64 characters 1 byte iSM13829 Server name is too long Classification ERROR Explanation computer name instance name is too long Measures Specify a ...

Page 353: ...ed database already exists aaa a Database name Measures Detach specified database and execute SQL command again iSM13832 Database name is too long Classification ERROR Explanation Specified database name is too long Measures Specify database name within 128 characters 1 byte iSM13833 Database operation file name is too long Classification ERROR Explanation Specified database operation file name is...

Page 354: ... is too long Classification ERROR Explanation Specified metafile storing folder name is too long Measures Specify metafile storing folder name within 256 characters 1 byte iSM13836 Number of database exceeds the limit that can be specified Classification ERROR Explanation The number of databases simultaneously operative exceeds specifiable upper limit Measures Reduce the number of databases simult...

Page 355: ...est information or restarting performance monitoring check current status and retry command execution iSM14401 Configuration reserved Disk Array aaa a status bbb b Classification INFO Explanation It indicates that configuration setting started aaa a Disk array name bbb b Execution state of the command good Normal failed xxxx Error occurred xxxx is error description Measures When an error occurs st...

Page 356: ...rom which configuration setting was made and connect the iSM client again iSM14403 LD bind LDN aaaa h aaaa h RANK bb h bb h PDG cc h status ddd d Classification INFO Explanation It indicates that the binding of Logical Disk was executed aaaa Logical disk number bb RANK number cc PD group number ddd d Execution state of the command good Normal failed xxxx Error occurred xxxx is error description Me...

Page 357: ...on or restarting state monitoring check current state and execute again iSM14405 RANK bind RANK aa h PDN bb h bb h PDG cc h Time dd RAID ee status fff f Classification INFO Explanation It indicates that the binding of RANK was executed aa RANK number bb Physical disk number cc PD group number dd Rebuilding time ee RAID type fff f Execution state of the command good Normal failed xxxx Error occurre...

Page 358: ...nformation or restarting state monitoring check current state and execute again iSM14407 Dynamic capacity expansion RANK aa h PDN bb h PDG cc h Time dd status eee e Classification INFO Explanation It indicates that the expansion of RANK was executed aa RANK number bb Physical disk number cc PD group number dd Rebuilding time eee e Execution state of the command good Normal failed xxxx Error occurr...

Page 359: ...After updating it to the newest information or restarting state monitoring check current state and execute again iSM14409 SPARE unbind PDN aa h aa h PDG bb h status ccc c Classification INFO Explanation It indicates that the unbinding of SPARE was executed aa Physical disk number bb PD group number ccc c Execution state of the command good Normal failed xxxx Error occurred xxxx is error descriptio...

Page 360: ...guration or setting of the disk array may be changed After updating it to the newest information or restarting state monitoring check current state and execute again iSM14411 Cross call mode aaa status bbb b Classification INFO Explanation It indicates that ON OFF of Cross call was set aaa on off bbb b Execution state of the command good Normal failed xxxx Error occurred xxxx is error description ...

Page 361: ...xecute again iSM14413 Rebuild maintenance RANK aa h PDN bb h PDG cc h Time dd status eee e Classification INFO Explanation It indicates that rebuilding to specified physical disk has been started aa RANK number bb Physical disk number cc PDG number dd Rebuilding time eee e Execution state of the command good Normal failed xxxx Error occurred xxxx is error description Measures When an error occurs ...

Page 362: ... updating it to the newest information or restarting state monitoring check current state and execute again iSM14415 Preventive Reduce maintenance RANK aa h PDN bb h PDG cc h status ddd d Classification INFO Explanation It indicates that preventive replacement was instructed to specified physical disk aa RANK number bb Physical disk number cc PD group number ddd d Execution state of the command go...

Page 363: ... may be changed After updating it to the newest information or restarting state monitoring check current state and execute again iSM14417 Set Rebuild time maintenance RANK aa h PDG bb h Time cc status ddd d Classification INFO Explanation It indicates that rebuilding time was changed for the physical disk under rebuilding process aa RANK number bb PD group number cc Rebuilding time ddd d Execution...

Page 364: ...ror occurs status failed was output the configuration or setting of the disk array may be changed After updating it to the newest information or restarting state monitoring check current state and execute again iSM14419 Temp sense interval maintenance interval aaaaa Classification INFO Explanation It indicates that temperature monitoring interval was set aaaaa Temperature monitoring interval Measu...

Page 365: ...rred xxxx is error description Measures When an error occurs status failed was output check whether the F W file or the state or subjected resource is normal iSM14421 Disk Array log init maintenance status aaa a Classification INFO Explanation It indicates that the initialization of internal log of Disk Array was executed aaa a Execution state of the command good Normal failed xxxx Error occurred ...

Page 366: ...disk array may be changed After updating it to the newest information or restarting state monitoring check current state and execute again iSM14423 PD recovery report init maintenance status aaa a Classification INFO Explanation It indicates that the PD recovery report within Disk Array was initialized aaa a Execution state of the command good Normal failed xxxx Error occurred xxxx is error descri...

Page 367: ...ating it to the newest information or restarting state monitoring check current state and execute again iSM14425 Set write cache mode maintenance aaa mode bbb status ccc c Classification INFO Explanation It indicates that ON OFF of write cache mode was set aaa BBU or CNT bbb on off ccc c Execution state of the command good Normal failed xxxx Error occurred xxxx is error description Measures When a...

Page 368: ...he disk array may be changed After updating it to the newest information or restarting state monitoring check current state and execute again iSM14427 LD format time Time aa status bbb b Classification INFO Explanation It indicates that format time of Logical Disk was changed aa Format time bbb b Execution state of the command good Normal failed xxxx Error occurred xxxx is error description Measur...

Page 369: ...the newest information or restarting state monitoring check current state and execute again iSM14429 Expand LUN mode HD aa h Port bb h mode cc status ddd d Classification INFO Explanation It indicates that Expand LUN mode was set aa on off bb Host Director number cc Port number ddd d Execution state of the command good Normal failed xxxx Error occurred xxxx is error description Measures When an er...

Page 370: ...ter updating it to the newest information or restarting state monitoring check current state and execute again iSM14431 Cancel LD reserve LDN aaaa h status bbb b Classification INFO Explanation It indicates that the Reserve Pool attribute was canceled aaaa Logical disk number bbb b Execution state of the command good Normal failed xxxx Error occurred xxxx is error description Measures When an erro...

Page 371: ...ter updating it to the newest information or restarting state monitoring check current state and execute again iSM14433 Stop data initialize LDN aaaa h status bbb b Classification INFO Explanation It indicates that initialization of the logical disk was suspended aaaa Logical disk number bbb b Execution state of the command good Normal failed xxxx Error occurred xxxx is error description Measures ...

Page 372: ...be changed After updating it to the newest information or restarting state monitoring check current state and execute again iSM14435 Set LD reserve optimization LDN aaaa h status bbb b Classification INFO Explanation It indicates that DVR attribute was set aaaa Logical disk number bbb b Execution state of the command good Normal failed xxxx Error occurred xxxx is error description Measures When an...

Page 373: ... updating it to the newest information or restarting state monitoring check current state and execute again iSM14437 Set default LD name LDN aaaa h status bbb b Classification INFO Explanation It indicates that the logical disk name was initialized to the default aaaa Logical disk number bbb b Execution state of the command good Normal failed xxxx Error occurred xxxx is error description Measures ...

Page 374: ...ay be changed After updating it to the newest information or restarting state monitoring check current state and execute again iSM14439 Shutdown Disk Array status aaa a Classification INFO Explanation Shutdown process of disk array started aaa a Command execution status good Normal failed xxxx Error occurred xxxx is error description Measures When an error occurs status failed was output the confi...

Page 375: ...toring check current state and execute again iSM14441 Storage Control Software update status aaa a Classification INFO Explanation It indicates that storage control software has been updated Upon normal operation iSM14439 and iSM14442 messages are output also aaa a Command execution status good Normal failed xxxx Error occurred xxxx is error description Measures When an error occurs status failed ...

Page 376: ...cessor all Whole disk array bb Resource number applicable to resetting all for the whole disk array ccc c Command execution status good Normal failed xxxx Error occurred xxxx is error description Measures When an error occurs status failed was output the configuration or setting of the disk array may be changed Check that accesses to disk array have terminated Turn off and then on the power and th...

Page 377: ...nge ccc c Subnet mask before change ddd d Gateway address before change eee e IP address after change fff f Subnet mask after change ggg g Gateway address after change hhh h Command execution status good Normal failed xxxx Error occurred xxxx is error description Measures When an error occurs status failed was output the configuration or setting of the disk array may be changed After updating it t...

Page 378: ...erver on or off ccc c IP address to allow access only when access restriction is on ddd d Command execution status good Normal failed xxxx Error occurred xxxx is error description Interrupted Measures When an error occurs status failed was output the configuration or setting of the disk array may be changed After updating it to the newest information or restarting state monitoring check current st...

Page 379: ...service processor aa Service processor number bb Access restriction status by SNMP request on or off ccc c Community name ddd d IP address to allow access only when access restriction is on eee e Command execution status good Normal failed xxxx Error occurred xxxx is error description Interrupted Measures When an error occurs status failed was output the configuration or setting of the disk array ...

Page 380: ...the disk array may be changed After updating it to the newest information or restarting state monitoring check current state and execute again iSM14447 License aaa a Product bbb b status ccc c Classification INFO Explanation It indicates that license was released or locked aaa a Setting type Release License released Lock License locked bbb b Program product name ccc c Command execution status good...

Page 381: ...fter resetting disk array or service processor aa Service processor number bbb b Community name ccc c IP address of SNMP Trap sending destination ddd d Command execution status good Normal failed xxxx Error occurred xxxx is error description Interrupted Measures When an error occurs status failed was output the configuration or setting of the disk array may be changed After updating it to the newe...

Page 382: ... ccc c Management information administrator of disk array managing department and contact address ddd d System name nickname of disk array using host name etc eee e Installation site installation sited of disk array fff f Supplementary information other information required for managing ggg g Command execution status good Normal failed xxxx Error occurred xxxx is error description Interrupted Meas...

Page 383: ...bbb Internal code such as errno Measures Check whether any abnormality has occurred in the processes making up the iSM server or in the operation environment then restart the iSM server iSM14601 Forced termination status aaa a Classification INFO Explanation It indicates that the Under configuration setting state was forcefully canceled aaa a Execution state of the command good Normal failed xxxx ...

Page 384: ...urred aaa a The following output will be provided depending on an error content communication detail communication system call detail system call process busy Time out in waiting for termination Windows version only bbbb Internal code such as errno Measures Check whether any abnormality has occurred in the processes making up the iSM server or in the operation environment then restart the iSM serv...

Page 385: ...ser name in environment setting Detail 2 file transfer information and restart iSM server iSM17002 Ftp environment ftp_root_directory is invalid File Transfer function can not be used detail aa bbbb Classification NOTICE Explanation File transfer function cannot be used because root directory of FTP server has not been defined correctly aa bbbb Detailed information This code isn t disorder reason ...

Page 386: ...nt setting Detail 2 file transfer information and restart iSM server iSM17004 Temp directory is not under ftp root directory File Transfer function can not be used detail aa bbbb Classification NOTICE Explanation File transfer function cannot be used because work file storing directory is not in the root directory of FTP server aa bbbb Detailed information This code isn t disorder reason but a val...

Page 387: ...son but a value for maintenance Measures Check function name and error number take appropriate measures and restart iSM server iSM17020 Socket access has failed func aaa a errno bbb detail cc dddd Classification WARNING Explanation An error occurred in socket access function aaa a Function name bbb Path name cc dddd Detailed information This code isn t disorder reason but a value for maintenance M...

Page 388: ...lue for maintenance Measures Check function name and error number take appropriate measures and restart iSM server iSM17040 System call error has occurred func aaa a errno bbb detail cc dddd Classification WARNING Explanation An error occurred in system function iSM server terminates abnormally aaa a Function name bbb Path name cc dddd Detailed information This code isn t disorder reason but a val...

Page 389: ...der reason but a value for maintenance Measures Save the following information and restart iSM server iSM operation log syslog for other than Windows system Event log for Windows system iSM17900 Process is busy when it terminates emergency Unexpected error message maybe generated Classification WARNING Explanation It indicates that file transfer function decided to execute emergency termination bu...

Page 390: ...d with the sever internal message of iSM client aaa a Server name bbb b Port name ccc c User name ddd d Client name iSM99002 Disconnected with iSM server Server aaa a Port bbb b User ccc c Client ddd d Classification INFO Explanation It was disconnected with the server internal message of iSM client aaa a Server name bbb b Port name ccc c User name ddd d Client name ...

Page 391: ...assification INFO Explanation Failed in SCSI command execution aaa a Additional information Measures Check connection between host and disk array iSMnetconf 111 Internal error has occurred aaa a Classification INFO Explanation An internal error occurred aaa a Additional information Measures Check that no problem exists in operating environment of this command and connection between host and disk a...

Page 392: ...s not exist Classification INFO Explanation Applicable resource does not exist Measures Check that service processor has been installed iSMnetconf 202 Many target resources exist Classification INFO Explanation Two or more applicable resources exist Measures Specify an applicable resource iSMnetconf 203 Only root can execute Classification INFO Explanation Execution is allowed for root authorized ...

Page 393: ...fied Disk Array Subsystem is set by another maintenance tool Classification INFO Explanation Specified disk array is being set by other tool Measures For executing this program terminate the setting by other tool iSMnetconf 221 Specified option is illegal Classification INFO Explanation Specified option is invalid Measures Specify a valid option iSMnetconf 222 Specified parameter is illegal Classi...

Page 394: ...224 Specified IP Address is illegal Classification INFO Explanation Specified IP address is invalid Measures Specify a valid IP address iSMnetconf 225 Specified Subnet Mask is illegal Classification INFO Explanation Specified subnet mask is invalid Measures Specify a valid subnet mask iSMnetconf 226 Specified Gateway Address is illegal Classification INFO Explanation Specified gateway address is i...

Page 395: ...the function where the error occurred cccc Error number Measures Specify a correct file or specify an appropriate access right iSMprfarc 103 Can t open directory aaa a func bbb b errno cccc Explanation The specified directory cannot be opened aaa a Name of the file to be opened bbb b Name of the function where the error occurred cccc Error number Measures Specify a correct directory or specify an ...

Page 396: ... of summarizing iSMprfarc 107 Can t find target file Explanation The specified directory doesn t contain the statistic info files corresponding to the target period of summarizing Measures Specify a correct directory or target period of summarizing iSMprfarc 108 No more archiving aaa a Explanation Statistic information secondary summarized files cannot be summarized aaa a Name of the specified fil...

Page 397: ... write bbb b Name of the function where the error occurred cccc Error number Measures Remove the cause of write failure iSMprfarc 112 Record broken aaa a Explanation The record of the input statistic info file is damaged aaa a Specified file name Measures Damaged statistic info files cannot be summarized Remove them from the target files iSMprfarc 201 Warning Find discontinuous file Explanation A ...

Page 398: ...ion Measures Specify the mandatory option and then re execute the command iSMprfctl 011 Illegal option aaa a Explanation An illegal option was specified aaa a Name of the illegal option Measures Specify the correct option and then re execute the command iSMprfctl 012 Missing option value aaa a Explanation No value has been specified in the option aaa a Name of the option in which no value has been...

Page 399: ... the command iSMprfctl 021 Specified Disk Array is invalid Explanation The command cannot be executed for the specified disk array because of the following The specified disk array is not one to be monitored by iSM The specified disk array is not permitted to use the performance optimization function Measures Check for the specified disk array name or the available product status iSMprfctl 022 Spe...

Page 400: ...sk exists in the specified disk array if the specified logical disk is defined as a work disk for optimization Measures Review the specification of the logical disk to be moved and then re execute the command iSMprfctl 031 Specified Optimization Work Disk is invalid Explanation The specification of the work disk for optimization is invalid Check if the specified work disk for optimization exists i...

Page 401: ...l Disk is multi rank type Explanation The specified logical disk to be moved is a multi RANK disk and it cannot be moved Measures Review the specification of the logical disk to be moved and then re execute the command iSMprfctl 035 Specified Logical Disk and Optimization Work Disk are in the same rank Explanation The logical disk to be moved and the work disk for optimization exist in the same RA...

Page 402: ...zation is identical to the name of another disk in the specified disk array Measures Correct the volume format specification of the work disk for optimization and then re execute the command iSMprfctl 040 Specified Logical Disk is under moving Explanation The specified logical disk to be moved is already moving Measures Review the specification of the logical disk to be moved and then re execute t...

Page 403: ...t be moved Measures Rebuild the work disk for optimization or specify another one and then re execute the command iSMprfctl 044 Number of movement exceeds permissible amount Explanation The number of specified disks to be concurrently moved exceeded the allowable maximum in the specified disk array Measures Confirm that the current Move command has terminated and then re execute the command iSMprf...

Page 404: ...rver aaa a Function name bbbb Error code cccccccc Detail code Measures Eliminate the error cause e g restarting the iSM server and then re execute the command iSMprfctl 051 Time out has occurred Explanation A timeout occurred during communication with the iSM server Measures Check for the iSM server status restart the iSM server if necessary and then re execute the command iSMprfctl 060 Insufficie...

Page 405: ...moving of the logical disk failed to start Measures Check the error cause according to the related messages recover the disk array from the error and then re execute the command iSMprfctl 910 Illegal function parameter Explanation An illegal subcommand was specified Measures Correct the specification of the subcommand and then re execute the command ...

Page 406: ...ng Measures Unnecessary iSMprfedit 100 Illegal option aaa a Explanation It indicates that a wrong option was specified aaa a Name of the wrong option String Measures Specify the option correctly and execute the command again iSMprfedit 101 Illegal file name aaa a Explanation It indicates that the name of the specified file is invalid other than psl and psa aaa a Invalid file name String Measures C...

Page 407: ... the error in Hexadecimal Measures Remove the cause of the open error based on the name of the function where the error occurred and the error number and execute the command again iSMprfedit 111 File close error aaa a func bbb b errno cccc ds dddddddd Explanation It indicates that an error occurred in the close process of the file aaa a Name of the file for which the error occurred in the close pr...

Page 408: ...le for which the error occurred in the write process String bbb b Name of the function where the error occurred String cccc Error number in Decimal dddddddd Detailed code of the error in Hexadecimal Measures Remove the cause of the write error based on the name of the function where the error occurred and the error number or change the location where the edit report is created by specifying the o ...

Page 409: ...r and execute the command again iSMprfedit 120 Illegal file format aaa a ds bbbbbbbb Explanation It indicates that a wrong file other than statistic information history file statistic information summarized file is specified aaa a Name of the wrong file String bbbbbbbb Detailed code of the error in Hexadecimal Measures Specify the correct file and execute the command again iSMprfedit 121 Data empt...

Page 410: ...ummarized file character string Measures A disk array with no function for collecting RANK statistic information does not contain RANK statistic information in statistic information history file statistic information summarized file Review parameters and retry command execution iSMprfedit 999 Unexpected error aaa a ds bbbbbbbb Explanation It indicates that an error occurred in the internal process...

Page 411: ...a Name of the option with wrong specification String Measures Correct the specification of the option and execute the command again iSMprfext 003 Illegal option value aaa a Explanation It indicates that the value of the specified option is invalid aaa a Name of the option with invalid value String Measures Correct the value of the option and execute the command again iSMprfext 004 File open error ...

Page 412: ...cess of the file aaa a Name of the file for which the error occurred in the input process String bbb b Name of the function where the error occurred String cccc Error number in Decimal dddddddd Detailed code of the error in Hexadecimal Measures Check whether the specified statistic information history file statistic information summarized file is damaged or not iSMprfext 007 Write error aaa a func...

Page 413: ...nformation history file statistic information summarized file does not contain statistic information to be converted to the CSV format aaa a Name of the specified statistic information history file statistic String Measures If any extraction conditions are specified check the conditions and execute the command again iSMprfext 010 Unexpected error aaa a ds bbbbbbbb Explanation It indicates that an ...

Page 414: ...nation It indicates that the number of records of the output file in the CSV format exceeded the upper limit 65 536 records aaa a Name of the output file CSV file String Measures Specify some extraction conditions to limit statistic information to extract and execute the command again ...

Page 415: ...t indicates that data accumulation in statistic information history file has already been started aaa a Disk array name Measures Check that specified disk array name is correct iSMprflog 003 Disk array aaa a logging is started overload interval bb Explanation It indicates that data accumulation in statistic information history file has been started By collecting statistic information disk array is...

Page 416: ...t data accumulation in statistic information history file has been already terminated aaa a Disk array name Measures Unnecessary iSMprflog 100 Missing option aaaaa Explanation It indicates that option has not been specified aaaaa Option name which should be specified Measures Specify required option and retry command execution iSMprflog 101 Illegal option aaaaa Explanation It indicates that specif...

Page 417: ...og 104 Illegal function parameter Explanation It indicates that a wrong parameter except start or stop was specified Measures Specify correct parameter and retry command execution iSMprflog 120 Disk array aaa a is not monitored Explanation It indicates that specified disk array is not monitored aaa a disk array name Measures Specify the disk array for monitoring and start or terminate accumulating...

Page 418: ...e Measures Take the following measures Against case 1 above Remove the causes of overloading and start accumulation of statistic information in statistic information history file Against case 2 above Stop monitoring and start troubleshooting And then restart monitoring and perform accumulation of statistic information in statistic information history file iSMprflog 900 System call error occurred f...

Page 419: ...X Solaris Windows iSM01001 INFO iSM01002 INFO iSM01003 INFO iSM01004 WARNING iSM01005 INFO iSM01006 WARNING iSM01010 INFO iSM01011 INFO iSM01101 WARNING iSM01102 NOTICE iSM01103 NOTICE iSM01105 NOTICE iSM01106 NOTICE iSM01107 WARNING iSM01108 NOTICE iSM01109 WARNING iSM01110 NOTICE iSM01111 NOTICE iSM01113 NOTICE iSM01230 WARNING iSM01232 ERROR iSM01400 iSM01401 iSM01402 iSM01403 iSM01404 iSM01405...

Page 420: ...Appendix A Message Output Destination List 415 iSM02020 NOTICE Output Not output when the default is selected ...

Page 421: ... iSM02053 INFO iSM02060 NOTICE iSM02061 NOTICE iSM03100 WARNING iSM03101 WARNING iSM03102 ERROR iSM03103 ERROR iSM03104 ERROR iSM03105 ERROR iSM03106 ERROR iSM03107 ERROR iSM03108 ERROR iSM03109 ERROR iSM03110 ERROR iSM03111 ERROR iSM03112 ERROR iSM03113 WARNING iSM03114 WARNING iSM03120 INFO iSM03121 WARNING iSM03122 INFO iSM03130 NOTICE iSM03131 NOTICE iSM03132 NOTICE iSM03133 NOTICE iSM03134 NO...

Page 422: ...Appendix A Message Output Destination List 417 Output Not output when the default is selected ...

Page 423: ...ROR iSM03300 INFO iSM03301 INFO iSM03302 WARNING iSM03303 INFO iSM03400 ERROR iSM03410 ERROR iSM03411 ERROR iSM03412 ERROR iSM03420 ERROR iSM03430 ERROR iSM03441 ERROR iSM03442 ERROR iSM03500 ERROR iSM03900 WARNING iSM04020 NOTICE iSM04021 NOTICE iSM04022 WARNING iSM04023 ERROR iSM04024 ERROR iSM04025 ERROR iSM04030 INFO iSM04040 WARNING iSM04060 INFO iSM06020 NOTICE iSM06021 NOTICE iSM06029 WARNI...

Page 424: ...Appendix A Message Output Destination List 419 iSM06038 WARNING Output Not output when the default is selected ...

Page 425: ...6050 WARNING iSM06051 WARNING iSM06062 WARNING iSM06063 WARNING iSM06064 WARNING iSM06065 WARNING iSM06066 WARNING iSM06070 WARNING iSM06071 WARNING iSM06080 INFO iSM06081 WARNING iSM06082 WARNING iSM06083 ERROR iSM06084 ERROR iSM06085 ERROR iSM06086 WARNING iSM06087 WARNING iSM06088 WARNING iSM06091 WARNING iSM06092 WARNING iSM06093 WARNING iSM06099 WARNING iSM06902 ERROR iSM07011 INFO iSM07012 I...

Page 426: ...Appendix A Message Output Destination List 421 Output Not output when the default is selected ...

Page 427: ...04 NOTICE iSM07105 NOTICE iSM07106 NOTICE iSM07108 ERROR iSM07109 ERROR iSM07111 INFO iSM07112 ERROR iSM07113 ERROR iSM07114 NOTICE iSM07121 INFO iSM07122 ERROR iSM07123 ERROR iSM07124 ERROR iSM07125 NOTICE iSM07126 NOTICE iSM07127 NOTICE iSM07128 NOTICE iSM07129 NOTICE iSM07130 NOTICE iSM07131 NOTICE iSM07132 NOTICE iSM07141 INFO iSM07142 ERROR iSM07143 ERROR iSM07144 NOTICE iSM07145 NOTICE iSM07...

Page 428: ...Appendix A Message Output Destination List 423 iSM07159 INFO Output Not output when the default is selected ...

Page 429: ...7175 NOTICE iSM07176 NOTICE iSM07177 NOTICE iSM07178 NOTICE iSM07179 NOTICE iSM07180 NOTICE iSM07181 NOTICE iSM07182 NOTICE iSM07191 INFO iSM07192 ERROR iSM07193 ERROR iSM07194 NOTICE iSM07195 NOTICE iSM07196 NOTICE iSM07197 NOTICE iSM07198 NOTICE iSM07201 INFO iSM07202 INFO iSM07203 INFO iSM07204 INFO iSM07205 NOTICE iSM07206 NOTICE iSM07207 NOTICE iSM07208 NOTICE iSM07211 INFO iSM07212 INFO iSM0...

Page 430: ...Appendix A Message Output Destination List 425 iSM07304 INFO Output Not output when the default is selected ...

Page 431: ...NFO iSM07310 INFO iSM07311 INFO iSM07312 INFO iSM07313 INFO iSM07314 INFO iSM07315 INFO iSM07316 INFO iSM07331 INFO iSM07332 INFO iSM07333 INFO iSM07334 INFO iSM07335 INFO iSM07336 INFO iSM07337 INFO iSM07338 INFO iSM07339 INFO iSM07340 INFO iSM07341 INFO iSM07342 INFO iSM07343 INFO iSM07344 INFO iSM07345 INFO iSM07346 INFO iSM07501 iSM07503 iSM07504 iSM07505 iSM07506 iSM07507 iSM07509 iSM07510 iS...

Page 432: ...Appendix A Message Output Destination List 427 iSM07553 NOTICE iSM07554 NOTICE Output Not output when the default is selected ...

Page 433: ... iSM08020 INFO iSM08021 INFO iSM08030 NOTICE iSM08031 NOTICE iSM08032 NOTICE iSM08033 NOTICE iSM08034 NOTICE iSM08035 NOTICE iSM08036 NOTICE iSM08037 NOTICE iSM08050 WARNING iSM08051 NOTICE iSM08052 NOTICE iSM08053 NOTICE iSM08054 NOTICE iSM08055 WARNING iSM08056 WARNING iSM08060 WARNING iSM08061 WARNING iSM08062 WARNING iSM08063 INFO iSM08070 NOTICE iSM08071 NOTICE iSM08072 NOTICE iSM08091 NOTICE...

Page 434: ...Appendix A Message Output Destination List 429 Output Not output when the default is selected ...

Page 435: ... iSM09009 NOTICE iSM09010 NOTICE iSM09011 NOTICE iSM09012 NOTICE iSM09013 NOTICE iSM09014 NOTICE iSM09015 NOTICE iSM09016 NOTICE iSM09017 NOTICE iSM09018 NOTICE iSM09019 NOTICE iSM09020 NOTICE iSM09021 NOTICE iSM09022 NOTICE iSM09099 NOTICE iSM09101 WARNING iSM09102 WARNING iSM09103 WARNING iSM09104 WARNING iSM09105 WARNING iSM09106 WARNING iSM09107 WARNING iSM09108 WARNING iSM10001 NOTICE iSM1000...

Page 436: ...Appendix A Message Output Destination List 431 Output Not output when the default is selected ...

Page 437: ...iSM10307 INFO iSM10308 INFO iSM10309 INFO iSM10310 NOTICE iSM10311 NOTICE iSM10312 NOTICE iSM10313 NOTICE iSM10314 NOTICE iSM10315 NOTICE iSM10316 NOTICE iSM10320 ERROR iSM10330 NOTICE iSM10400 NOTICE iSM10401 ERROR iSM10402 WARNING iSM10403 ERROR iSM10410 NOTICE iSM10411 NOTICE iSM10420 NOTICE iSM10430 ERROR iSM10440 NOTICE iSM10900 WARNING iSM11100 INFO iSM11101 INFO iSM11102 INFO iSM11103 INFO ...

Page 438: ...Appendix A Message Output Destination List 433 iSM11153 INFO Output Not output when the default is selected ...

Page 439: ... iSM11172 INFO iSM11173 INFO iSM11174 INFO iSM11175 INFO iSM11176 INFO iSM11178 INFO iSM11179 INFO iSM11180 INFO iSM11181 INFO iSM11220 INFO iSM11221 INFO iSM11222 INFO iSM11230 INFO iSM11231 INFO iSM11232 INFO iSM11233 INFO iSM11234 INFO iSM11235 INFO iSM11236 INFO iSM11237 INFO iSM11240 INFO iSM11241 INFO iSM11242 INFO iSM11250 INFO iSM11251 INFO iSM11252 INFO iSM11253 INFO iSM11255 INFO iSM1125...

Page 440: ...Appendix A Message Output Destination List 435 iSM11310 INFO Output Not output when the default is selected ...

Page 441: ... iSM11360 INFO iSM11361 INFO iSM11362 INFO iSM11363 INFO iSM11364 INFO iSM11365 INFO iSM11366 INFO iSM11367 INFO iSM11369 INFO iSM11370 INFO iSM11372 INFO iSM11373 INFO iSM11374 INFO iSM11375 INFO iSM11376 INFO iSM11377 INFO iSM11378 INFO iSM11379 INFO iSM11380 INFO iSM11381 INFO iSM11382 INFO iSM11383 INFO iSM11384 INFO iSM11385 INFO iSM11402 INFO iSM11403 INFO iSM11404 INFO iSM11405 INFO iSM1140...

Page 442: ...Appendix A Message Output Destination List 437 iSM11415 INFO Output Not output when the default is selected ...

Page 443: ... iSM11424 INFO iSM11425 INFO iSM11426 INFO iSM11429 INFO iSM11431 INFO iSM11438 INFO iSM11439 INFO iSM11440 INFO iSM11442 INFO iSM11443 INFO iSM11444 INFO iSM11455 INFO iSM11486 INFO iSM11487 INFO iSM11501 INFO iSM11502 INFO iSM11503 INFO iSM11504 INFO iSM11505 INFO iSM11506 INFO iSM11507 INFO iSM11508 INFO iSM11509 INFO iSM11510 INFO iSM11521 INFO iSM11522 INFO iSM11531 INFO iSM11532 INFO iSM1153...

Page 444: ...Appendix A Message Output Destination List 439 iSM11542 INFO Output Not output when the default is selected ...

Page 445: ...62 INFO iSM11563 INFO iSM11564 INFO iSM11565 INFO iSM11566 INFO iSM11567 INFO iSM11568 INFO iSM11569 INFO iSM11570 INFO iSM11571 INFO iSM11572 INFO iSM11573 INFO iSM11574 INFO iSM11575 INFO iSM11600 INFO iSM11601 INFO iSM11602 INFO iSM11603 INFO iSM11700 INFO iSM11701 INFO iSM11702 ERROR iSM11703 ERROR iSM11704 ERROR iSM11705 ERROR iSM11706 ERROR iSM11707 ERROR iSM11708 ERROR iSM11709 ERROR iSM117...

Page 446: ...Appendix A Message Output Destination List 441 iSM11728 ERROR Output Not output when the default is selected ...

Page 447: ...OR iSM11737 ERROR iSM11738 ERROR iSM11742 ERROR iSM11743 ERROR iSM11744 ERROR iSM11745 ERROR iSM11746 ERROR iSM11747 ERROR iSM11748 ERROR iSM11749 ERROR iSM11750 ERROR iSM11751 ERROR iSM11755 ERROR iSM11756 ERROR iSM11757 ERROR iSM11758 ERROR iSM11759 ERROR iSM11760 ERROR iSM11781 ERROR iSM11782 ERROR iSM11783 ERROR iSM11784 ERROR iSM11785 ERROR iSM11786 ERROR iSM11787 ERROR iSM11791 ERROR iSM1179...

Page 448: ...Appendix A Message Output Destination List 443 iSM11803 INFO Output Not output when the default is selected ...

Page 449: ...NFO iSM13206 INFO iSM13207 INFO iSM13208 INFO iSM13209 INFO iSM13210 INFO iSM13211 INFO iSM13212 INFO iSM13213 INFO iSM13214 INFO iSM13215 INFO iSM13216 INFO iSM13220 INFO iSM13221 INFO iSM13222 INFO iSM13223 INFO iSM13224 INFO iSM13228 INFO iSM13229 INFO iSM13230 INFO iSM13231 INFO iSM13232 INFO iSM13233 INFO iSM13234 INFO iSM13235 INFO iSM13240 INFO iSM13241 INFO iSM13242 INFO iSM13243 INFO iSM1...

Page 450: ...Appendix A Message Output Destination List 445 Output Not output when the default is selected ...

Page 451: ...5 WARNING iSM13500 ERROR iSM13501 ERROR iSM13502 ERROR iSM13503 ERROR iSM13504 ERROR iSM13505 ERROR iSM13506 ERROR iSM13507 ERROR iSM13508 ERROR iSM13509 ERROR iSM13510 ERROR iSM13511 ERROR iSM13512 ERROR iSM13513 ERROR iSM13514 ERROR iSM13515 ERROR iSM13516 ERROR iSM13517 ERROR iSM13518 ERROR iSM13519 ERROR iSM13520 ERROR iSM13521 ERROR iSM13522 ERROR iSM13523 ERROR iSM13524 ERROR iSM13525 ERROR ...

Page 452: ...Appendix A Message Output Destination List 447 iSM13538 ERROR Output Not output when the default is selected ...

Page 453: ...R iSM13551 ERROR iSM13552 ERROR iSM13555 ERROR iSM13556 ERROR iSM13557 ERROR iSM13558 ERROR iSM13559 ERROR iSM13561 ERROR iSM13562 ERROR iSM13563 ERROR iSM13564 ERROR iSM13565 ERROR iSM13566 ERROR iSM13567 ERROR iSM13569 ERROR iSM13570 ERROR iSM13571 ERROR iSM13573 ERROR iSM13574 ERROR iSM13575 ERROR iSM13576 ERROR iSM13577 ERROR iSM13578 ERROR iSM13579 ERROR iSM13581 ERROR iSM13582 ERROR iSM13583...

Page 454: ...Appendix A Message Output Destination List 449 Output Not output when the default is selected ...

Page 455: ...05 ERROR iSM13607 ERROR iSM13608 ERROR iSM13609 ERROR iSM13610 ERROR iSM13613 ERROR iSM13614 ERROR iSM13615 ERROR iSM13618 ERROR iSM13619 ERROR iSM13623 ERROR iSM13626 ERROR iSM13627 ERROR iSM13629 ERROR iSM13630 ERROR iSM13631 ERROR iSM13632 ERROR iSM13633 ERROR iSM13634 ERROR iSM13635 ERROR iSM13636 ERROR iSM13637 ERROR iSM13638 ERROR iSM13639 ERROR iSM13641 ERROR iSM13642 ERROR iSM13643 ERROR i...

Page 456: ...Appendix A Message Output Destination List 451 iSM13656 ERROR Output Not output when the default is selected ...

Page 457: ...75 ERROR iSM13676 ERROR iSM13679 ERROR iSM13680 ERROR iSM13681 ERROR iSM13682 ERROR iSM13683 ERROR iSM13684 ERROR iSM13685 ERROR iSM13686 ERROR iSM13687 ERROR iSM13688 ERROR iSM13689 ERROR iSM13690 ERROR iSM13691 ERROR iSM13692 ERROR iSM13693 ERROR iSM13694 ERROR iSM13695 ERROR iSM13696 ERROR iSM13697 ERROR iSM13698 ERROR iSM13699 ERROR iSM13700 ERROR iSM13701 ERROR iSM13702 ERROR iSM13703 ERROR i...

Page 458: ...Appendix A Message Output Destination List 453 iSM13712 ERROR Output Not output when the default is selected ...

Page 459: ...20 ERROR iSM13721 ERROR iSM13722 ERROR iSM13723 ERROR iSM13724 ERROR iSM13725 ERROR iSM13726 ERROR iSM13727 ERROR iSM13728 ERROR iSM13729 ERROR iSM13730 ERROR iSM13731 ERROR iSM13732 ERROR iSM13733 ERROR iSM13734 ERROR iSM13735 ERROR iSM13736 ERROR iSM13737 ERROR iSM13738 ERROR iSM13739 ERROR iSM13740 ERROR iSM13741 ERROR iSM13742 ERROR iSM13743 ERROR iSM13744 ERROR iSM13745 ERROR iSM13746 ERROR i...

Page 460: ...Appendix A Message Output Destination List 455 iSM13755 ERROR iSM13800 ERROR Output Not output when the default is selected ...

Page 461: ...M13809 ERROR iSM13810 ERROR iSM13811 ERROR iSM13812 ERROR iSM13813 ERROR iSM13814 ERROR iSM13815 ERROR iSM13816 ERROR iSM13817 ERROR iSM13818 ERROR iSM13819 ERROR iSM13820 ERROR iSM13821 ERROR iSM13822 ERROR iSM13823 ERROR iSM13824 ERROR iSM13825 ERROR iSM13826 ERROR iSM13827 ERROR iSM13828 ERROR iSM13829 ERROR iSM13830 ERROR iSM13831 ERROR iSM13832 ERROR iSM13833 ERROR iSM13834 ERROR iSM13835 ERR...

Page 462: ...Appendix A Message Output Destination List 457 iSM14407 INFO Output Not output when the default is selected ...

Page 463: ...14 INFO iSM14415 INFO iSM14416 INFO iSM14417 INFO iSM14418 INFO iSM14419 INFO iSM14420 INFO iSM14421 INFO iSM14422 INFO iSM14423 INFO iSM14424 INFO iSM14425 INFO iSM14426 INFO iSM14427 INFO iSM14428 INFO iSM14429 INFO iSM14430 INFO iSM14431 INFO iSM14432 INFO iSM14433 INFO iSM14434 INFO iSM14435 INFO iSM14436 INFO iSM14437 INFO iSM14438 INFO iSM14439 INFO iSM14440 INFO iSM14441 INFO iSM14442 INFO ...

Page 464: ...Appendix A Message Output Destination List 459 iSM14600 INFO iSM14601 INFO Output Not output when the default is selected ...

Page 465: ...M17050 WARNING iSM17900 WARNING iSM99001 INFO iSM99002 INFO iSMnetconf 001 INFO iSMnetconf 101 INFO iSMnetconf 111 INFO iSMnetconf 112 INFO iSMnetconf 201 INFO iSMnetconf 202 INFO iSMnetconf 203 INFO iSMnetconf 211 INFO iSMnetconf 212 INFO iSMnetconf 221 INFO iSMnetconf 222 INFO iSMnetconf 223 INFO iSMnetconf 224 INFO iSMnetconf 225 INFO iSMnetconf 226 INFO iSMprfarc 101 iSMprfarc 102 iSMprfarc 10...

Page 466: ...Appendix A Message Output Destination List 461 iSMprfctl 010 Output Not output when the default is selected ...

Page 467: ...ctl 023 iSMprfctl 030 iSMprfctl 031 iSMprfctl 032 iSMprfctl 033 iSMprfctl 034 iSMprfctl 035 iSMprfctl 036 iSMprfctl 037 iSMprfctl 040 iSMprfctl 041 iSMprfctl 042 iSMprfctl 043 iSMprfctl 044 iSMprfctl 050 iSMprfctl 051 iSMprfctl 060 iSMprfctl 090 iSMprfctl 910 iSMprfedit 001 iSMprfedit 100 iSMprfedit 101 iSMprfedit 102 iSMprfedit 103 iSMprfedit 110 iSMprfedit 111 iSMprfedit 112 iSMprfedit 113 iSMpr...

Page 468: ...Appendix A Message Output Destination List 463 Output Not output when the default is selected ...

Page 469: ...ndows iSMprfext 002 iSMprfext 003 iSMprfext 004 iSMprfext 005 iSMprfext 006 iSMprfext 007 iSMprfext 008 iSMprfext 009 iSMprfext 010 iSMprfext 011 iSMprflog 001 iSMprflog 002 iSMprflog 003 iSMprflog 010 iSMprflog 011 iSMprflog 100 iSMprflog 101 iSMprflog 102 iSMprflog 103 iSMprflog 104 iSMprflog 120 iSMprflog 121 iSMprflog 122 iSMprflog 123 iSMprflog 900 Output Not output when the default is select...

Page 470: ...ered client aaaaaaaa ip bbb b Old iSM03226 New All control paths of aaa a productID bbbbb SN ccccc are not available detail dd eeee ERROR Old Process busy when terminate emergency unexpected error messages maybe generated iSM03900 New Process is busy when it terminates emergency Unexpected error message maybe generated Old Log File has swapped the latest backup aa iSM04040 New Log File has swapped...

Page 471: ...eeds 256 bytes line aaa Old Shell file not exist file aaa a iSM06050 New Shell file does not exist file aaa a Old Shell file not executable file aaa a iSM06051 New Shell file is not executable file aaa a Old Message buffer full data lost detected iSM06070 New Message buffer is full Data lost detected Old Definition change success iSM06080 New Definition change is successful Old Definition change e...

Page 472: ...rror HEADER is not defined Old iSM07220 New SVP information was updated aaa a productID bbbbb SN ccccc No dd h Old iSM07221 New Product information was changed aaa a productID bbbbb SN ccccc Old ACCESS_CONTROL mode was changed into WWN aaaaa No bb h cc h iSM07312 New ACCESS_CONTROL mode was changed into aaaa bbbbb No cc h dd h Old iSM07314 New ACCESS_CONTROL function was stopped aaaaa Old iSM07344...

Page 473: ...dddd WARNING Old iSM08056 New Restoration of threshold monitoring object failed disk array aaa a func bbbb errno cccc detcode dddddddd WARNING Old Successful name aaa a iSM08080 New Old Already name aaa a iSM08081 New Old Not watched name aaa a iSM08082 New Old Not exist name aaa a iSM08083 New Old There is no disk array iSM08084 New Old Successful ovld name aaa a iSM08085 New Old Overload name aa...

Page 474: ...stem State bbb b Back Ground Copy Level ccc c several states changed NOTICE Old iSM10314 New Logical Disks were paired mv aaa a bbb b h ccc c rv aaa a bbb b h ccc c several states changed NOTICE Old iSM10315 New Logical Disks were unpaired mv aaa a bbb b h ccc c rv aaa a bbb b h ccc c several states changed NOTICE Old iSM10316 New Replication state of pair was changed mv aaa a bbb b h ccc c Activi...

Page 475: ...or end of aaa a iSM11155 New Failed to request notification for termination of aaa a Old iSM11181 New WWPN does not exist INFO Old Port configuration is needed iSM11231 New Port configuration is required Old Cannot set Access Control function Cross call function must work when using Access Control function It sets up from the main menu iSM11232 New Cannot set Access Control function Cross call fun...

Page 476: ...fied ld_number does not exist in volume list data Old Specified ld_name doesn t exist in volume list data iSM11724 New Specified ld_name does not exist in volume list data Old Specified drive doesn t exist in volume list data iSM11725 New Specified drive does not exist in volume list data Old Specified disk_number doesn t exist in volume list data iSM11726 New Specified disk_number does not exist ...

Page 477: ...finition file ERROR Old iSM11746 New Failed to close target volume definition file ERROR Old iSM11747 New Failed to close target control volume list data ERROR Old iSM11748 New Target control volume list data has invalid data ERROR Old iSM11749 New Control volume is not found ERROR Old popen ps command failed iSM11750 New Failed to execute popen Old ReplicationControl command has already started i...

Page 478: ...lready restored MV aaa a RV aaa a iSM13216 New These targets have already restored MV aaa a RV aaa a Old to set drive letter aaa a succeeded iSM13220 New Setting drive letter aaa a has succeeded Old to set mount point bbb b succeeded iSM13220 New Setting mount point bbb b has succeeded Old to reset drive letter aaa a succeeded iSM13221 New Resetting drive letter aaa a has succeeded Old to reset mo...

Page 479: ...ew Importing file succeeded aaa a records Old iSM13240 New SnapshotBackup Start aaaa bb cc dd ee ff INFO Old iSM13241 New SnapshotBackup Normal End aaaa bb cc dd ee ff INFO Old iSM13242 New SnapshotBackup Abnormal End aaaa bb cc dd ee ff INFO Old iSM13243 New SnapshotRestore Start aaaa bb cc dd ee ff INFO Old iSM13244 New SnapshotRestore Normal End aaaa bb cc dd ee ff INFO Old iSM13245 New Snapsho...

Page 480: ...ode is foreground iSM13413 New Target pair s copy mode is foreground Old iSM13414 New Conflict of volume list data has been detected Please update volume list data WARNING Old iSM13415 New Specified volume was ignored aaa a WARNING Old insufficient option aaa a iSM13500 New Insufficient option aaa a Old specified options are duplicated aaa a iSM13501 New Specified options are duplicated aaa a Old ...

Page 481: ...V iSM13517 New Number of LD MV is not equal to that of LD RV Old illegal value of wait second aaa a iSM13518 New Illegal value of wait second aaa a Old illegal value of RPL_WATCHDEV aaa a iSM13519 New Illegal value of RPL_WATCHDEV aaa a Old illegal value of RPL_ENDWATCHDEV aaa a iSM13520 New Illegal value of RPL_ENDWATCHDEV aaa a Old specified volume group does not exist vg aaa a iSM13521 New Spec...

Page 482: ...to that of LD RV filename aaa a line bbb b iSM13537 New Number of LD MV is not equal to that of LD RV filename aaa a line bbb b Old specified file is empty filename aaa a line bbb b iSM13538 New Specified file is empty filename aaa a line bbb b Old specified RV is not available to force iSM13539 New Specified RV is not available to force Old illegal volflg type aaa a iSM13540 New Illegal volflg ty...

Page 483: ...icating restoring at the same time iSM13564 New This connection does not allow replicating restoring at the same time Old upper pair is not separated iSM13565 New Upper pair is not separated Old lower pair is not separated iSM13566 New Lower pair is not separated Old specified disk array s status is freeze iSM13567 New Specified disk array s status is freeze Old target pair is replicating now iSM1...

Page 484: ...no bbb Old volume list is missing or unexpected error occurred error code aa iSM13585 New Volume list is missing or unexpected error occurred error code aa Old specified drive letter has already existed iSM13587 New Specified drive letter has already existed Old volume list error iSM13591 New Volume list error Old target pair is not separated iSM13592 New Target pair is not separated Old license f...

Page 485: ...cified volume does not have signature volume aaa a iSM13613 New Specified volume does not have signature volume aaa a Old failed to read signature volume aaa a iSM13614 New Failed to read signature volume aaa a Old failed to read signature map file errno aaa iSM13615 New Failed to read signature map file errno aaa Old specified volume does not exist in signature map file volume aaa a iSM13618 New ...

Page 486: ...ified path aaa a is not correct directory iSM13637 New Specified path aaa a is not correct directory Old this OS version does not support specified function iSM13638 New This OS version does not support specified function Old specified path is not normal status iSM13639 New Specified path is not normal status Old firmware does not support aaa a function iSM13641 New Firmware does not support aaa a...

Page 487: ... the limit option aaa sec Old specified targets are not ready iSM13659 New Specified targets are not ready Old replicating was aborted by other process abandon waiting for command termination iSM13660 New Replicate command has terminated because activity status is changed by other process Old restoring was aborted by other process abandon waiting for command termination iSM13661 New Restore comman...

Page 488: ...iSM13687 New Metafile aaa a is not found Old failed to metafile aaa a open iSM13688 New Failed to metafile aaa a open Old failed to snapshot execution iSM13689 New Failed to snapshot execution code aaa a Old failed to sql command execution iSM13690 New Failed to sql command execution Old dbname does not exist in SQL server iSM13691 New Dbname does not exist in SQL server Old specified volume has m...

Page 489: ... Server code aaa a bbb b bbb b bbb b ERROR Old iSM13705 New Receive data is incorrect Data mismatch may has occurred in iSM Server code aaa a bbb b bbb b bbb b ERROR Old iSM13706 New No more RV can be paired with specified MV code aaa a bbb b bbb b bbb b ERROR Old iSM13707 New Specified RV has already paired with other MV code aaa a bbb b bbb b bbb b ERROR Old iSM13708 New Specified pair will buil...

Page 490: ...b bbb b ERROR Old iSM13720 New License for DynamicDataReplication RemoteDataReplication is locked code aaa a bbb b bbb b bbb b ERROR Old iSM13721 New DynamicDataReplication RemoteDataReplication is not supported code aaa a bbb b bbb b bbb b ERROR Old iSM13722 New Specified volume does not exist in Logical disk list code aaa a bbb b bbb b bbb b ERROR Old iSM13723 New State of Disk Array includes sp...

Page 491: ...eady paired with other volume on same Disk Array as RV code aaa a bbb b bbb b bbb b ERROR Old iSM13735 New Specified RV has already paired with other volume on same Disk Array as MV code aaa a bbb b bbb b bbb b ERROR Old iSM13736 New Failed to open target control volume list data ERROR Old iSM13737 New Failed to close target control volume list data ERROR Old iSM13738 New Target control volume lis...

Page 492: ...OR Old iSM13750 New Volume list data does not exist ERROR Old iSM13751 New Volume type is not ld ERROR Old iSM13752 New Timeout error has occurred in iSM Server ERROR Old iSM13753 New Disconnected from iSM Server ERROR Old iSM13754 New Replication function of iSM Server is not ready ERROR Old iSM13755 New Command issue to aaa a failed ERROR Old iSM13800 New No such database name filename aaa a lin...

Page 493: ... Old iSM13814 New Illegal combination of options input filename aaa a line bbb b ERROR Old iSM13815 New Options uid can not be omitted are specified filename aaa a line bbb b ERROR Old iSM13816 New Options remod and set value standby can not be omitted are specified filename aaa a line bbb b ERROR Old iSM13817 New Specified database name is duplicated filename aaa a line bbb b ERROR Old iSM13818 N...

Page 494: ...ROR Old iSM13833 New Database operation file name is too long ERROR Old iSM13834 New Metafile name is too long ERROR Old iSM13835 New Metafolder name is too long ERROR Old iSM13836 New Number of database exceeds the limit that can be specified ERROR Old Configuration reserved Disk Array Disk Array aaa a status bbb b iSM14401 New Configuration reserved Disk Array aaa a status bbb b Old Configuratio...

Page 495: ...M14447 New License aaa a Product bbb b status ccc c INFO Old iSM14448 New Set SNMP Trap Transmission number aa h Community Name bbb b SNMP Trap Transmission IP Address ccc c ccc c status ddd d INFO Old iSM14449 New Set SNMP Trap Information number aa h Trap Sense Interval bb Unit Contact ccc c Unit Name ddd d Unit Location eee e Unit Info fff f status ggg g INFO Old iSM17001 New FTP environment us...

Page 496: ...aybe generated WARNING Old iSMnetconf 001 New Command complete successfully INFO Old iSMnetconf 101 New Command has failed aaa a INFO Old iSMnetconf 111 New Internal error has occurred aaa a INFO Old iSMnetconf 112 New Changed to the alternative path aaa a INFO Old iSMnetconf 201 New Resource does not exist INFO Old iSMnetconf 202 New Many target resources exist INFO Old iSMnetconf 203 New Only ro...

Page 497: ...llegal option aaa a Old illegal file name aaa a iSMprfedit 101 New Illegal file name aaa a Old missing file name iSMprfedit 102 New Missing file name Old missing option aaa a iSMprfedit 103 New Missing option aaa a Old file open error aaa a func bbb b errno cccc ds dddddddd iSMprfedit 110 New File open error aaa a func bbb b errno cccc ds dddddddd Old file close error aaa a func bbb b errno cccc d...

Page 498: ...ile open error aaa a func bbb b errno cccc iSMprfext 004 New File open error aaa a func bbb b errno cccc Old file close error aaa a func bbb b errno cccc iSMprfext 005 New File close error aaa a func bbb b errno cccc Old read error aaa a func bbb b errno cccc ds dddddddd iSMprfext 006 New Read error aaa a func bbb b errno cccc ds dddddddd Old write error aaa a func bbb b errno cccc iSMprfext 007 N...

Page 499: ...sk array aaa a logging is stopped Old iSMprflog 011 New Disk array aaa a logging is already stopped Old iSMprflog 100 New Missing option aaa Old iSMprflog 101 New Illegal option aaaaa Old iSMprflog 102 New Missing option value aaaaa Old iSMprflog 103 New Illegal option value aaa Old iSMprflog 104 New Illegal function parameter Old iSMprflog 120 New Disk array aaa a is not watched Old iSMprflog 121...