manualshive.com logo in svg
background image

NA - Ultra5 Housing

For SmallHD Ultra5 Camera Monitor

PN 17926

Introduction

2

2

3

4

7

8

Package Contents

Important Instructions

Part Names and Functions

Opening the Housing

Closing the Housing

9

16

13

Setup Options

Preparation for Use

Cable Connection

19

20

21

Care/Storage

Warranty

Specifications

User Manual

Housing

Monitor

July, 2023

Содержание NA-Ultra5 Housing

Страница 1: ...uction 2 2 3 4 7 8 Package Contents Important Instructions Part Names and Functions Opening the Housing Closing the Housing 9 16 13 Setup Options Preparation for Use Cable Connection 19 20 21 Care Sto...

Страница 2: ...e all the included items listed below before using this product If some items are missing or damaged contact your local Nauticam dealer Pre installed items 25625 M16 Vacuum Valve II 25089 M28 HDMI 2 0...

Страница 3: ...ervised and or given instruction by a responsible person concerning use of the product to ensure that they can use it safely Do not seal the housing when travelling by air as this may lead to a pressu...

Страница 4: ...FUNCTIONS Joystick Right button Joystick Up button Joystick Left button Joystick Down button Back button Custom F1 button Custom F3 button Custom F2 button 1 2 3 4 5 7 6 8 Rear View 2 4 5 8 6 7 3 1 A...

Страница 5: ...5 PART NAMES AND FUNCTIONS M28 Accessory port Mounting ball Sacrificial zinc anodes 1 2 3 Front Bottom Views 3 2 1...

Страница 6: ...NAMES AND FUNCTIONS Top Side Views Pre installed M16 Vacuum valve II ON OFF button Housing unlock button Moisture alarm window M28 Accessory port Pre installed M28 HDMI 2 0 Adaptor 3 5 6 1 2 4 3 4 1...

Страница 7: ...THE HOUSING 1 2 3 depress housing unlock button turn housing lock latch anti clockwise to open the housing flip open the back housing when lock latch is aligned to open position drawings as illustrat...

Страница 8: ...nothing is caught between front and back housing and that they are fully aligned before locking main O ring insert the housing shaft into the shaft hole and then rotate the lock latch clockwise until...

Страница 9: ...dapter pre installed HDMI 1 4 Cable HDMI 1 4 Cable SDI Cable in 0 4m length SDI Surface monitor cable 15m or 45m M28 to M16 Adaptor M16 SDI Bulkhead M16 HDMI Bulkhead M24 to M16 Adaptor or M28 to M16...

Страница 10: ...ng on camera housing M28 HDMI 2 0 Adaptor or M24 HDMI 2 0 Adaptor depending on camera housing Connect to surface Connect to housing HDMI 2 0 Cable HDMI 2 0 Cable 25089 25089 or or or M28 HDMI 2 0 Adap...

Страница 11: ...SDI Cable Set Heightened M28 Adaptor included in 17926S packaging Heightened M28 Adaptor included in 17926S packaging for Raptor housings before SN A545638 please use 96184 M24 Adaptor instead for Ra...

Страница 12: ...es LEMO 4 pin to 9 pin adaptor cable 16265R includes LEMO 4 pin to 9 pin adaptor cable 16265A or 16265R or 16265S 16265A or 16265R or 16265S SDI Ethernet Power All In One Camera control cable bundle f...

Страница 13: ...rew it onto the monitor housing if the M28 HDMI 2 0 Adaptor is pre installed simply remove the cap from the housing plug the cable into the Port connect the cable onto monitor housing by securing the...

Страница 14: ...ble then place the monitor inside the housing connect the SDI cable then place the monitor inside the housing connect the All in one cable then place the monitor inside the housing secure the monitor...

Страница 15: ...6 SDI Bulkhead 25060 SDI cable and SDI surface cable is not included in the package SDI Surface Cable Cap M16 SDI Bulkhead Cap M 28 Plug M16 SDI Bulkhead M28 to M16 adaptor turn the locking levers in...

Страница 16: ...ing an O ring remover clean the O ring groove with a cloth and ensure that it is free from salt or other foreign materials lightly coat it with provided lubricant return the main O ring by slowly pres...

Страница 17: ...refer to page 18 for complete vacuum system guidance 1 3 2 4 remove battery insulation film switch on the alarm the moisture alarm window will flash in BLUE when it is working correctly test the alar...

Страница 18: ...test again hand pump moisture alarm window vacuum valve 1 2 Moisture alarm window colour indication Steady Blue Flashing Blue Steady Green Steady Red Flashing Yellow Flashing Red Alternating Blue and...

Страница 19: ...ot travel with monitor inside housing Operate all controls and buttons at least 3 times while immersed in fresh water We recommand cleaning and inspecting the main O ring each time after diving for an...

Страница 20: ...d service center s Please note that this warranty only applies when the product is pur chased in the territory where the service center is lo cated NAUTICAM accepts no liability for any damage to and...

Страница 21: ...D Micro Battery Plate for V Mount when used with the Fxlion NANO ONE 50Wh 14 8V Ultra Compact V Mount battery 17954 Universal Tripod Plate for Nauticam Housings Width In air Rating Display window 1795...

Страница 22: ...Nauticam Internationl Ltd Rm 2203 CCT Telecom Bldg 11 Wo Shing St Fo Tan Hong Kong Tel 852 26902711 Fax 852 26909778 URL www nauticam com Gallery www nauticam smugmug com...

Отзывы: