SAVE THESE INSTRUCTIONS 

500 Watt Puresine Solar Power Generator

User Manual

Item # 40500

V1.1-M 5May2021

WARNING:

                       Read carefully and understand all assembly and operation instructions before 

operating. Failure to follow the safety rules and other basic safety precautions may result in 

serious personal injury.

Summary of Contents for 40500

Page 1: ...r Generator User Manual Item 40500 V1 1 M 5May2021 WARNING Read carefully and understand all assembly and operation instructions before operating Failure to follow the safety rules and other basic safety precautions may result in serious personal injury ...

Page 2: ...d responsible manner Do not allow persons to operate or assemble the product until they have read this manual and have developed a thorough understanding of how it works Do not modify this product in any way Unauthorized modification may impair the function and or safety and could affect the life of the product There are specific applications for which the product was designed Use the right tool f...

Page 3: ...pen place for remote observation after confirmation of safety contact the manufacturer or dealer This product has a built in high voltage power supply and battery keep away from children For long term storage more than one month please charge the power generator to about 70 Do not charge near fire or overheating Use or place Precautions when working with solar panels With the incidence of sunlight...

Page 4: ... charging and city electricity Light weight small size high power etc providing customers with convenient mobile energy power generator can meet the power supply needs of most household appliances such as rice cookers small refrigerators speakers televisions mobile phones computers cameras camcorders tablets LED lights emergency lights drones power tools Medical equipment etc Contains a wide range...

Page 5: ...ge 5 of 12 LCD DISPLAY HANDLE USB USB C OUTPUT 2X 110V AC OUTPUT CHARGING DC POWER INDICATOR DC POWER SWITCH AC POWER SWITCH SOLAR INPUT COOLING FAN CAR CHARGE IN 12V 10A OUT SOLAR IN 120W MAX AC IN DC5525 OUT Item 40500 ...

Page 6: ...he power generator will slowly drain the battery power Can be used normally after the load is disconnected and fully charged The power generator is equipped with 4 charging ports Adapter indicator light turns to green when its powered turns to red when charging the generator And then green again when fully charged Please disconnect after fully charged 1 AC Charging 110V AC Charger AC Output Power ...

Page 7: ...uired 3 Solar Charging 1 The included 10W Semiflex solar panels coming with DC socket connector can directly connect to the solar port for charging the other solar panels with DC socket connector and less than 120W can be the same 2 If solar panel coming with a SAE connector and less than 120W the included SAE DC socket cable can be use to connecting power generator for charge Noted Note LCD displ...

Page 8: ...imum 120W output DC5525 port DC5525 is not controlled by the DC power switch Same port as AC IN Maximum 60W output 2 DC Output Turn on the DC power switch Please turn it off in time after charging 3 USB Type C Output AC Output DC Output USB USB C Output 4 Powered Devices Common Devices for each charging port Work light 100W Around 5 Hours Fan 60W Around 8 Hours Laptop 30W Around 16 Hours Portable ...

Page 9: ... load 90 the lower the load power the higher the discharge efficiency 70 load 90 the lower the load power the higher the discharge efficiency Over current over Charge over discharge Short Circuit Protection Power Capacity Voltage Lifecycle AC Charger Input Voltage Output Frequency Output Power DC5525 Cigarette Socket Efficiency AC Adapter AC Charger Input Voltage Solar Charging Solar Charging Inpu...

Page 10: ...ime when the output power is greater than the input power the battery power reducing slowly when it is reduced to a low power state the output will be turned off Does this power generator have temperature protection When it is used in a high temperature environment if the internal temperature higher than 50 the circuit will be turned off for battery protection Why are there 2 solar charging ports ...

Page 11: ... may not be compatible Accidental shutdown during product use This power generator has a built in real time safety monitoring system which may cause unit to shut down because of the internal protection system startup This will protect from overcharging over discharge high temperature over current overload and short circuit In order to solve the problem quickly remove all electrical equipment keep ...

Page 12: ...at the purchasers expense A dated proof of purchase is required to receive warranty service Once received at authorized location and defect proves to be the result of defective material and workmanship the defective part or unit will be replaced at warrantors option and returned to the original purchaser at warrantors expense No refunds will be granted by the warrantor in the event of buyer s remo...