background image

FUEL CONVERSION KITS FOR BURNERS

B81L, B81G, B81S

INSTALLER: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOME OWNER.

CHECK THE BOXES TO INDICATE THAT THE CORRESPONDING STEPS HAVE BEEN COMPLETED.

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada        •  (705)721-1212         •  fax (705)720-9081       • www.napoleonfireplaces.com

WARNING:

  Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this 

appliance may result in property damage or personal injury.

CAUTION:  Before proceeding with conversion the gas supply must be shut off prior to disconnecting the electrical power.

1.

  Remove the door and log set or glass from the fireplace. Refer to the “FINISHING” section of your installation manual for instructions.

2.  Logs Only

: Remove the center log support bracket (4 screws). Then remove the four tube burner cap brackets (8 screws).

2.  Glass/Rock Only:

 Remove the porcelain base (4 screws). Then remove the burner assembly (4 screws). (Carefully, not to damage the    

      pilot line)

3.

  Remove the tube burner(s).

4.

  Using a deep socket wrench, remove both orifices.  A back-up wrench must be used on the manifold to ensure that the tubing does 

not twist or kink.  Using pipe thread compound, replace with the orifices supplied. 

 

5.  

Before replacing the burners, adjust the air shutters according to the table located on the back of this page.

                                                                                                                                                                                          

Continued on reverse 

This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s 

instructions and all applicable codes and requirements of the authority having jurisdiction.  If the information 

in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result 

causing property damage, personal injury or loss of life.  The qualified service agency is responsible 

for the proper installation of this kit.  The installation is not proper and complete until the operation 

of the converted appliance is checked as specified in the owner instructions supplied with the kit.

W415-0956 / A / 12.09.16

B81L

B81G/B81S

B81L/B81G/B81S

 W175-0308 NG TO P

 W175-0313 NG TO P

 W175-0312 P TO NG

1

STEP MOTOR / REGULATOR

STEP MOTOR / REGULATOR

STEP MOTOR / REGULATOR

1

#53 BURNER ORIFICE

#52 Outer Ring BURNER ORIFICE

#34 BURNER ORIFICE

1

#53 BURNER ORIFICE

#54 Inner Tube BURNER ORIFICE

#34 BURNER ORIFICE

1

CONVERSION DATA LABEL

CONVERSION DATA LABEL

CONVERSION DATA LABEL

1

PILOT INJECTOR

PILOT INJECTOR

PILOT INJECTOR

CENTER LOG 

SUPPORT BRACKET

BURNER TUBE

PORCELAIN

BASE

BURNER ASSEMBLY

ORIFICES

CAP 

BRACKETS

ORIFICES

LOG BURNER

GLASS BURNER

#52

#54

ROCK BURNER

GLASS/ROCK BURNER

PORCELAIN

BASE

SCREWS

Summary of Contents for W175-0308 NG TO P

Page 1: ...und replace with the orifices supplied 5 Before replacing the burners adjust the air shutters according to the table located on the back of this page Continued on reverse This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructionsandallapplicablecodesandrequirementsoftheauthorityhavingjurisdiction Iftheinformation in these instructions is...

Page 2: ...water column for natural gas or 13 11 minimum water column for propane Check that main burner is operating on HI Outlet pressure can be checked the same as above using screw B Gauge should read 3 5 water column for natural gas or 10 water column for propane Check that main burner is operating on HI AFTER TAKING PRESSURE READINGS TIGHTEN SCREWS FIRMLY TO SEAL DO NOT OVER TORQUE LEAK TEST ADJUSTMENT...

Page 3: ...NS DOIVENT ÊTRE GARDÉES PAR LE PROPRIÉTAIRE VEUILLEZ COCHER LES CASES POUR INDIQUER QUE LES ÉTAPES CORRESPONDANTES ONT ÉTÉ COMPLÉTÉES ENSEMBLES DE CONVERSION POUR LES BRÛLEURS B81L B81G B81S Cet ensemble de conversion doit être installé par une agence d entretien qualifiée conformément aux instructions du fabricant et à tous les codes et les exigences des autorités compétentes Si ces instructions ...

Page 4: ...pection visuelle de la flamme de la veilleuse et du brûleur Comparez la à ces illustrations 7 Retirez la hotte de dérivation de flamme de l assemblage de la veilleuse en tirant à la verticale Utilisez une clé Allen pour dévisser l injecteur Remplacer l injecteur par celui qui est fourni Replacez la hotte de dérivation de flamme sur l assemblage de la veilleuse en vous assurant qu elle soit bien al...