background image

 

 

 

1|5                                                                                                                                                                    datasheet-HL80-2209-en.1.1 
                                                                                                                                                                                                                                                                                                     

HL80 Series LED High Mast Light 

 

 

Products description and application 

HL80 series modular LED high mast lights, combined with a variety of optical 
lenses, provide lighting solutions with high efficiency, energy saving and low 
maintenance rate, and provide stable and comfortable lighting effects for the 
lighting area, so that staff can focus more on work safety and improve work 
efficiency. It is mainly used for industrial lighting in ports, large-scale 
operation mines, airports, stadiums and other places.

 

Features 

 

High thermal conductivity aluminum extrusion molding heat sink, 
improve LED service life. 

 

Well-designed heat flow channels keep the luminaire excellent heat 
dissipation performance. 

 

Equipped with waterproof and breathable valve to balance the 
temperature and pressure inside and outside the lamp to protect the 
LED light source device. 

 

A variety of optical light distribution options are available for more 
lighting scenarios. 

 

Clear and visible illumination angle adjustment, suitable for lighting in a 
variety of different positions. 

 

Optional light shield can be used to make the light interception effect of 
lamps better and effectively reduce glare. 

General Specifications 

Standard 

CE

 

EN60598-1

EN60598-2-5

EN62493

EN62471

EN55015

EN61547

EN61000-3-2

EN61000-3-3 

UL

 

UL1598

UL8750/CSA C22.2 NO250.0-08

CSA C22.2 No250.13 

Electrical 

 

Mechanical 

 

Rated voltage 

100-240VAC 

Color 

Silvery white 

Frequency 

50/60Hz   

Housing 

Aluminum alloy 

Rated power 

400W 600W 800W 1000W 

Cover 

PC 

PF 

PF

0.9 

Finish 

Anodized 

EMC 

IEC61000-4-2 Contact discharge:8KV   

Weight 

12Kg 17Kg 22Kg 28Kg 

 

Air discharge:15KV 

Mounting 

Bracket 

 

IEC61000-4-3 800~1000MHz 10V/m 

Ta 

-

40˚C ~ +50˚C 

 

IEC61000-4-4 ±2KV 

Vibration level 

ANSI C136.31    1.5g 

 

IEC61000-4-5 DM:±6KV    CM:±10KV

[1]

 

IP Rate 

IEC60529    IP67 

 

IEC61000-4-6 0.15~80MHz 10V/m 

Anti-corrosion 

ISO12944    C5 M 

 

EN55015 CLASS C 

 

 

Wiring method 

Lead wire 

 

 

Photometric 

 

 

 

Light source

 

LED

 

Source life

 

≥50000h

 

Color temp 

Cold white:5700K Warm white:2700K 

Beam angle 

30°/60°/

Asymmetric

20°×100° 

CRI 

Cold white

:Ra≥70 Warm white:Ra≥80 

 

 

Luminous 
efficacy 

30°/60°

Cold white:150lm/W Warm white:125lm/W 

Asymmetric

20°×100°

Cold white:140lm/W Warm white:120lm/W 

[1] 

 

This standard test meets the functional state B. It is normal for the lamp to flash at the moment of surge, and it can be 

automatically recovered. 

Summary of Contents for HL80 Series

Page 1: ...rent positions Optional light shield can be used to make the light interception effect of lamps better and effectively reduce glare General Specifications Standard CE EN60598 1 EN60598 2 5 EN62493 EN62471 EN55015 EN61547 EN61000 3 2 EN61000 3 3 UL UL1598 UL8750 CSA C22 2 NO250 0 08 CSA C22 2 No250 13 Electrical Mechanical Rated voltage 100 240VAC Color Silvery white Frequency 50 60Hz Housing Alumi...

Page 2: ... 2 The installation height is greater than 3 m two or more screws are required 3 Adjust the fixture to the angle and direction that needs to be illuminated and fix it firmly 3 1 3 2 3 3 4 Fix the safety chain in a suitable place and the fixing surface should have sufficient mechanical strength 930 430 374 171 316 HL80 400W HL80 600W HL80 800W HL80 1000W 90 150 240 14 14 80 180 14 14 300 80 180 14 ...

Page 3: ...irect installation on the surface of common combustible materials 5 The shortest distance between the lamp and the object to be illuminated is 3 meters to avoid fire 6 When using the lamp do not look directly at the bright light source 7 When the lamp is in use the surface of the shell and lampshade has a certain temperature rise which is a normal phenomenon 8 Replacement and maintenance of lamps ...

Page 4: ...57mm 1000521_015 HL80 A600CM1B 100 240VAC 600W 5700K 30 Lead wire 2m Bracket stretch out 6mm hole spacing 80 180mm high257mm 1000521_016 HL80 A600CW1B 100 240VAC 600W 5700K 60 Lead wire 2m Bracket stretch out 6mm hole spacing 80 180mm high257mm 1000521_017 HL80 A600CR1B 100 240VAC 600W 5700K 20 100 Lead wire 2m Bracket stretch out 6mm hole spacing 80 180mm high257mm 1000521_019 HL80 A800WM1C 100 2...

Page 5: ...n your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Thanks for choosing our products NANHUA Electronics is the professional brand of signal transmission and high quality industrial lighting which is trusted and loved by global users from various industries Read and unders...

Reviews: