background image

 

  1 

 

  50 

 

consumption

NADAMOO 

User Guide 

 

This User Guide Applies to E3000

H

E3100

H

))

 

V1.1.1 

Summary of Contents for E3000

Page 1: ...第 1 页 共 50 页 consumption NADAMOO User Guide This User Guide Applies to E3000 H E3100 H V1 1 1 ...

Page 2: ...r part of this guide is prohibited to excerpt copy bundle other products or sell without the written permission from us Version Record Version number Version description Version date V0 0 1 Add part of unrecognized setting code 2015 05 26 V0 0 2 1 Add lights and position light control 2 Add communication mode USB KBW and USB serial port 3 Trigger mode add auto induction mode 2015 07 27 V0 0 3 Add ...

Page 3: ...Add prompt switch function Add matrix 25 code and standard 25 code 2016 11 17 V1 0 2 Add specific SSI instructions 2017 02 21 V1 0 3 Add new function Modify some contents of the manual 2017 04 21 V1 0 4 Add event report Wiegand PS2 set password mode disable passive trigger scan instruction form 2017 06 15 V1 3 12 1 Solve the problem of VAT invoice output 2017 06 29 V1 3 13 1 USB KBW added to suppo...

Page 4: ...mm 2 1 4 Interface description 2 1 5 Communication port 3 1 6 Peripheral circuit diagram 4 1 6 1 buzzer 4 1 6 2 button 4 1 6 3 LED 5 1 7 Communication port 5 1 8 Supported code system 6 1 9 Start up shutdown standby and restart 6 1 10 Maintenance 7 1 11 Reading skills 7 2 barcode setting 8 2 1 Mark setting 8 2 2 Setting barcodes 8 ...

Page 5: ...rn on Turn off configuration code 11 2 2 9 Enable Disable sending setting code 11 2 2 10 Power mode 11 2 2 11 Sensitivity setting 11 2 2 12 Invoice automatic identification and output only for China 12 2 2 13 Invoice character type only for China 12 2 2 14 Invoice type only for China 13 2 3 Volume and light setting 13 2 3 1 indicator light setting 13 2 3 2 Successful decode indicate setting 13 2 3...

Page 6: ... 16 2 4 7 Bookland EAN ISBN 17 2 4 8 UPC EAN Addendum Code 17 2 4 9 Convert UPC E TO UPC A 17 2 4 10 Enable Disable Code 128 17 2 4 11 Enable Disable GS1 128 18 2 4 12 Enable Disable Code 39 18 2 4 13 Enable Disable Code 93 18 2 4 14 Enable Disable Code 11 18 2 4 15 Enable Disable ITF25 19 2 4 16 Enable Disable industrial ITF25 19 2 4 17 Enable Disable Codabar 19 2 4 18 Enable Disable MSI 19 2 4 1...

Page 7: ...mmunication setting 22 2 5 1 Baud rate setting 22 2 5 2 check bit setting 22 2 5 3 stop bit setting 23 2 5 4 The retard of characters 23 2 6 Prefix and suffix setting 24 2 6 1 Prefix and suffix setting 24 2 6 2 compound mode setting 24 2 7 Mark barcode transfer type setting 25 2 7 1 Disable mark barcode transfer type 25 2 7 2 Enable mark barcode transfer type 25 2 8 Chinese character encode 26 2 8...

Page 8: ... 3 Enable Disable decode function 30 3 4 serial port communication setting 32 3 5 Prefix and suffix setting 33 3 6 Mark barcode transfer type setting 33 appendix 35 Appendix 1 Number setting code 35 Appendix 2 set prefix and suffix by serial port instructions 37 Appendix 3 barcode sample 41 ...

Page 9: ...t of patent plug and play without the need to install driver Wide voltage design to avoid the data can t be transmitted due to voltage fluctuation 32 bit master chip equipped with patented software the scanner can smoothly decode reflective wrinkled blurred and colorful barcode and can also normally scan in light and dark environment Adopt all tantalum capacitors and anti oxidation optical technol...

Page 10: ...rface description Product standard interfaces are RS232 DB9 orifice TTL USB Keyboard USD HID Keyboard and Wiegand Standard interface of different products are not the same please confirm before purchase other interfaces can be customized according to customer needs ...

Page 11: ...Serial input port TTL level 5 Tx output Serial input port TTL level 6 USB_D Input output USB_D signal 7 USB_D Input output USB_D signal 8 NC Empty Spare 9 BPR output Buzzer output signal 10 LED output Indicator light output signal 11 NC Input Reset signal input Active low Maintain more than100us can reset product 12 TRIG Input Trigger to scan ...

Page 12: ...4 1 6 Peripheral circuit diagram 1 6 1 buzzer 1 6 2 button ...

Page 13: ...D 1 7 Communication port The scanner must be connected to a host to operate Host can be a PC POS machine intelligent terminal with USB or RS 232 interface USB USB interface on host RS 232 RS 232 interface on host ...

Page 14: ...3 Q AZTEC CODE x 3 z MAXI CODE x 3 U 1 9 Start up shutdown standby and restart Start up Connect host computer with scanner which will automatically start up and in working state Shutdown Remove the data cable which is connected with scanner remove the USB which is connected with host computer remove the power adapter which is inserted into RS 232 serial port Standby Scanner with automatic sleep st...

Page 15: ...s lens cleaning cloth Spraying liquid onto the window is prohibited Prohibit any cleaning solvents except for the cleaning water 1 11 Reading skills If the barcode is small it should be closer to the scanning window if the barcode is large it should be far away from the scanning window a little more thus easier to be read correctly If the barcode is highly reflective for example the coated surface...

Page 16: ...ion of the options and functions available for user setting and the corresponding setup code This method of setting the scanning is direct easy to understand and user friendly 2 1 Mark setting 2 2 Setting barcodes 2 2 1 Reset to default configuration 2 2 2 Communication mode setting USB virtual serial port USB Serial port Reset to default configuration 1 2 Reset to default configuration ...

Page 17: ...e cancel setting in the appendix 2 2 4 trigger mode setting Choose one of the below mode as trigger event for scanning engine Scan standard press trigger to active red light to decode barcode the red light will stay on and decoding until you release the trigger or exceed the decode scanning time Scan pulse press trigger to active red light to decode barcode the red light will stay on until success...

Page 18: ...t less than two numbers For example you want to set 0 5 second as interval time scan the barcode below then scan 0 5 at the appendix If you want to change or cancel one incorrect setting scan the cancel setting in the appendix 2 2 6 scan time interval setting of the same barcode Auto mode When the scanner is in auto mode this re scanning setting will come out the result with one barcode when you s...

Page 19: ... working In continuous power mode scanner module keep awake 2 2 11 Sensitivity setting To set sensitivity when the barcode scanner is in auto mode Query this parameter you can get a number feedback represent the sensitivity level Special level 0 Disable Configuration Code Enable Configuration Code Enter TAB Enable sending setting code Disable sending setting code Continuous power mode Power saving...

Page 20: ...el 15 Default high level 2 2 12 Invoice automatic identification and output only for China 2 2 13 Invoice character type only for China Low sensitivity Special sensitivity High sensitivity Middle sensitivity close default open English character default on UTF8 character ...

Page 21: ...ing To set the meaning of the indicator light 2 3 2 Successful decode indicate setting If decode successfully the indicator light on for a while on condition that the indicator light has been set to represent decode 2 3 3 Volume setting special invoice default Plain invoice Represent power Represent decode Off On Volume Low ...

Page 22: ...14 Reset to default configuration 2 3 4 Mute setting Turn on or off all volume 2 3 5 Starting up sound setting 2 3 6 setting code volume 2 3 7 LED setting Off Volume Middle Volume High Off On off on On ...

Page 23: ...tion 2 3 8 positioning lamp setting 2 4 Enable Disable decode function 2 4 1 code system character output 2 4 2 Enable Disable UPC A LED on when reading Always on Always off Always on when reading Always on Always off On Off Enable ...

Page 24: ...o default configuration 2 4 3 Enable Disable UPC E 2 4 4 Enable Disable EAN 8 2 4 5 Enable Disable EAN 13 2 4 6 Enable Disable Bookland EAN ISBN Disable Enable Disable Enable Disable Enable Disable Enable Disable ...

Page 25: ...ndum Code 2 4 9 Convert UPC E TO UPC A 2 4 10 Enable Disable Code 128 Bookland ISBN 10 Bookland ISBN 13 Disable UPC EAN Addendum Code Only identify UPC EAN with addendum code Auto identify UPC EAN Addendum code Enable Convert UPC E to UPC A Disable Convert UPC E to UPC A Enable ...

Page 26: ...nable Disable GS1 128 2 4 12 Enable Disable Code 39 2 4 13 Enable Disable Code 93 2 4 14 Enable Disable Code 11 Disable Enable GS1 128 Disable GS1 128 Enable Code 39 Disable Code 39 Disable Code 93 Enable Code 11 Disable Code 11 Enable Code 93 ...

Page 27: ...Disable industrial ITF25 2 4 17 Enable Disable Codabar 2 4 18 Enable Disable MSI 2 4 19 Enable Disable GS1 DataBar RSS 14 Enable ITF25 Disable ITF25 Enable industrial ITF25 Disable industrial ITF25 Enable Codabar Disable Codabar Enable MSI Disable MSI Enable GS1 DataBar RSS 14 ...

Page 28: ...20 Enable Disable PDF417 2 4 21 Enable Disable QR 2 4 22 Enable Disable single double QR Enable single QR default Enable double QR Enable single and double QR code Disable GS1 DataBar RSS 14 Enable PDF417 Disable PDF417 Enable QR Disable QR ...

Page 29: ... Data Matrix DM 2 4 25 Enable Disable Maxi Code 2 4 26 Enable Disable Aztec Code 2 4 27 Enable Disable Chinese code Enable MicroQRCode Disable MicroQRCode Enable Data Matrix DM Disable Data Matrix DM Enable Maxi Code Disable Maxi Code Enable Aztec Code Disable Aztec Code Enable Chinese code ...

Page 30: ... check bit is the most important bit in ASCII so you need to choose odd bit or even bit based on you host If you choose odd check bit the check bit will have a value between 0 and 1 and make sure one odd bit will be contained in the code character based on the data If you choose even check bit the check bit will have a value between 0 and 1 and make sure one even bit will be contained in the code ...

Page 31: ...he retard of characters The retard of characters can give host time to serve the receiver and execute other tasks between characters To set the retard of characters must match the requirements of the host The retarded time is in the rank of 0ms to 99ms the smallest unit is 1ms If you want to set the retarded time scan the below barcode first then scan two numbers as the retarded time For example y...

Page 32: ...dix II and II based on ASCII If you want to change or cancel one incorrect setting scan the cancel setting in the appendix Remark If you want to set prefix and suffix you must scan the barcode below to set the content of prefix and suffix first 2 6 2 compound mode setting Scan the barcode below to set the compound mode you want retard of characters default 0ms Prefix 1 Suffix 1 Suffix 1 delete pre...

Page 33: ...isable mark barcode transfer type 2 7 2 Enable mark barcode transfer type Barcode suffix 2 Barcode suffix 1 suffix 2 Prefix barcode Prefix barcode suffix 1 Prefix barcode suffix 2 Prefix barcode suffix 1 suffix 2 Enable mark barcode transfer type Disable mark barcode transfer type ...

Page 34: ...se character encode 2 8 1 Disable Chinese character encode 2 8 2 GBK GB2312 Be suited to TXT Excel type software display Default setting 2 8 3 UNICODE Be suited to QQ WORD type software display Disable Chinese character encode GBK GB2312 UNICODE ...

Page 35: ...ns need to count the check bit like prefix and suffix Other instructions and use directly based on below table 3 1 Basic Configuration function Instructions HEX Reset to default configuration 08 C6 04 08 00 F2 FF 00 FD 35 Communication mode setting Serial port 08 C6 04 08 00 F2 01 00 FE 33 USB HID 08 C6 04 08 00 F2 01 01 FE 32 USB virtual serial port 08 C6 04 08 00 F2 01 02 FE 31 Decode scanning t...

Page 36: ... Disable 08 C6 04 08 00 F1 71 00 FD C4 Power mode Continuous power mode 07 C6 04 08 00 80 00 FE A7 Power saving mode 07 C6 04 08 00 80 01 FE A6 Re scanning time Auto mode 1500ms 08 C6 04 08 00 F3 03 0F FE 21 500ms 08 C6 04 08 00 F3 03 05 FE 2B 300ms 08 C6 04 08 00 F3 03 03 FE 2D Sensitivity setting Special sensitivity 08 C6 04 08 00 F2 04 00 FE 30 High sensitivity 08 C6 04 08 00 F2 04 01 FE 2F Mid...

Page 37: ...tting On 08 C6 04 08 00 F2 0D 00 FE 27 Off 08 C6 04 08 00 F2 0D 01 FE 26 setting code volume On 08 C6 04 08 00 F2 0E 00 FE 26 Off 08 C6 04 08 00 F2 0E 01 FE 25 Decode successful volume On 07 C6 04 08 00 38 01 FE EE Off 07 C6 04 08 00 38 00 FE EF Lamp control Light up when decoding 08 C6 04 08 00 F2 02 00 FE 32 Always on 08 C6 04 08 00 F2 02 01 FE 31 Always off 08 C6 04 08 00 F2 02 02 FE 30 positio...

Page 38: ...07 C6 04 08 00 02 01 FF 24 Convert UPC E TO UPC A off 07 C6 04 08 00 25 00 FF 02 on 07 C6 04 08 00 25 01 FF 01 EAN 8 off 07 C6 04 08 00 04 00 FF 23 on 07 C6 04 08 00 04 01 FF 22 EAN 8 develop to EAN 13 off 07 C6 04 08 00 27 00 FF 00 on 07 C6 04 08 00 27 01 FE FF EAN 13 off 07 C6 04 08 00 03 00 FF 24 on 07 C6 04 08 00 03 01 FF 23 Bookland EAN ISBN off 07 C6 04 08 00 53 00 FE D4 on 07 C6 04 08 00 53...

Page 39: ...0 FF 1D on 07 C6 04 08 00 0A 01 FF 1C ITF25 off 07 C6 04 08 00 06 00 FF 21 on 07 C6 04 08 00 06 01 FF 20 industrial ITF25 off 07 C6 04 08 00 05 00 FF 22 on 07 C6 04 08 00 05 01 FF 21 Codabar off 07 C6 04 08 00 07 00 FF 20 on 07 C6 04 08 00 07 01 FF 1F MSI off 07 C6 04 08 00 0B 00 FF 1C on 07 C6 04 08 00 0B 01 FF 1B GS1 DataBar RSS 14 off 08 C6 04 08 00 F0 52 00 FD E4 on 08 C6 04 08 00 F0 52 01 FD ...

Page 40: ...0 F0 2F 00 FE 07 on 08 C6 04 08 00 F0 2F 01 FE 06 3 4 serial port communication setting Function Instructions HEX Baud rate setting 9600 07 C6 04 08 00 9C 06 FE 85 19200 07 C6 04 08 00 9C 07 FE 84 38400 07 C6 04 08 00 9C 08 FE 83 57600 07 C6 04 08 00 9C 09 FE 82 115200 07 C6 04 08 00 9C 0A FE 81 check bit setting Odd 07 C6 04 08 00 9E 00 FE 89 Even 07 C6 04 08 00 9E 01 FE 88 Mark 07 C6 04 08 00 9E...

Page 41: ...x 1 07 C6 04 08 00 EB 01 FE 3B Barcode suffix 2 07 C6 04 08 00 EB 02 FE 3A Barcode suffix 1 suffix 2 07 C6 04 08 00 EB 03 FE 39 Prefix barcode 07 C6 04 08 00 EB 04 FE 38 Prefix barcode suffix 1 07 C6 04 08 00 EB 05 FE 37 Prefix barcode suffix 2 07 C6 04 08 00 EB 06 FE 36 Prefix barcode suffix 1 suffix 2 07 C6 04 08 00 EB 07 FE 35 3 6 Mark barcode transfer type setting Function Instructions HEX Mar...

Page 42: ...Han Xin e GS1 D ataBar L PDF417 d Data Matrix DM Q QR z Aztec Code U Maxi Code m modifier meaning Code type Value GS1 128 0 Standard data package no function code 1 in the first character position 1 Function code 1 in the first character position 2 Function code 1 in the second character position For example GSI 128 barcode with function code 1 in the first character position will be transferred a...

Page 43: ...35 Reset to default configuration appendix Appendix 1 Number setting code When setting needs exact number scan the barcode below to set numbers Number Barcode 0 1 2 3 4 5 6 7 8 ...

Page 44: ...36 Reset to default configuration 9 Cancel Change setting or cancel one wrong barcode by scan this barcode ...

Page 45: ... the following table ASCII code Hex system Keyboard value 1000 00h CTRL 2 1001 01h CTRL A 1002 02h CTRL B 1003 03h CTRL C 1004 04h CTRL D 1005 05h CTRL E 1006 06h CTRL F 1007 07h CTRL G 1008 08h CTRL H 1009 09h CTRL I 1010 0Ah CTRL J 1011 0Bh CTRL K 1012 0Ch CTRL L 1013 0Dh CTRL M 1014 0Eh CTRL N 1015 0Fh CTRL O 1016 10h CTRL P 1017 11h CTRL Q 1018 12h CTRL R 1019 13h CTRL S 1020 14h CTRL T 1021 1...

Page 46: ...Bh 1044 2Ch 1045 2Dh 1046 2Eh 1047 2Fh 1048 30h 0 1049 31h 1 1050 32h 2 1051 33h 3 1052 34h 4 1053 35h 5 1054 36h 6 1055 37h 7 1056 38h 8 1057 39h 9 1058 3Ah 1059 3Bh 1060 3Ch 1061 3Dh 1062 3Eh 1063 3Fh 1064 40h 1065 41h A 1066 42h B 1067 43h C 1068 44h D 1069 45h E 1070 46h F 1071 47h G 1072 48h H 1073 49h I 1074 4Ah J 1075 4Bh K ...

Page 47: ...6 56h V 1087 57h W 1088 58h X 1089 59h Y 1090 5Ah Z 1091 5Bh 1092 5Ch 1093 5Dh 1094 5Eh 1095 5Fh _ 1096 60h 1097 61h a 1098 62h b 1099 63h c 1100 64h d 1101 65h e 1102 66h f 1103 67h g 1104 68h h 1105 69h i 1106 6Ah j 1107 6Bh k 1108 6Ch l 1109 6Dh m 1110 6Eh n 1111 6Fh o 1112 70h p 1113 71h q 1114 72h r 1115 73h s 1116 74h t 1117 75h u 1118 76h v ...

Page 48: ...40 Reset to default configuration 1119 77h w 1120 78h x 1121 79h y 1122 7Ah z 1123 7Bh 1124 7Ch 1125 7Dh 1126 7Eh 1127 76h v ...

Page 49: ...to default configuration Appendix 3 barcode sample Name Barcode sample Remark EAN13 UPC A EAN8 UPC E Default data 1234565 Codabar Encoded data c01235d Code93 Code39 Regular Code 39 FullASCII Encoded data Code 39 ...

Page 50: ......

Reviews: