xtreme DB

DP-34044-3 User Guide

A Murrelektronik Company

Summary of Contents for DataPanel xtreme DB DP-34044-3

Page 1: ...1 A Murrelektronik Company xtreme DB DP 34044 3 User Guide A Murrelektronik Company...

Page 2: ...Rate 7 4 2 Configuring the Node ID 8 4 3 Powering the Module 9 4 4 LEDs 10 4 4 1 LED Status 11 4 5 Circuit Protection 12 5 Module Configuration 13 5 1 Configuration Steps 13 5 2 Output Configuration...

Page 3: ...ry may perform configuration installation set up maintenance and testing of the equipment 2 3 REGULATIONS Current safety and accident prevention laws valid for a specific application must be observed...

Page 4: ...re indicated by text and a corresponding symbol inside of a frame CAUTION Disregard of safety measures may result in damage to equipment and other serious consequences 3 INSTALLATION 3 1 XtremeDB INST...

Page 5: ...A Murrelektronik Company 5 3 8 2 0 0 2 8 1 10 4 10 4 1 3 3 8 1 3 0 2 10 4 10 4 1 3 ATTENTION Modules must be mounted a minimum of 3mm from each other...

Page 6: ...6 Configuration Power Plug CAN Ports 1 2 Non Isolated 16 Outputs 4 MODULE OVERVIEW...

Page 7: ...1 7 of the Power and Configuration plug shown below Currently there are 2 baud rates supported 250kb and 500kb If you are connecting to a 250kb network no jumpers are required If connecting to a 500kb...

Page 8: ...D 61413 PGN Node ID 1 s 2 s 4 s 8 s PGN Source Address 0 0 0 0 0 61408 224 1 1 0 0 0 61409 225 2 0 1 0 0 61410 226 3 1 1 0 0 61411 227 4 0 0 1 0 61412 228 5 1 0 1 0 61413 229 6 0 1 1 0 61414 230 7 1 1...

Page 9: ...amps and is used to power connected modules down the line This power is also used for all input ports as well The first and last Node on the network must have a 120 Ohm terminating resistor Please not...

Page 10: ...Power for ports 1 2 P2 Power for ports 3 4 P3 Power for ports 5 6 P4 Power for ports 7 8 FLT LED Red Fault Status STAT LED Green Module Status PORT I O LED Yellow Left LED Output A Right LED Output B...

Page 11: ...on ON OFF F0 Bootload Mode 1 Short 1 Short F1 Output Over Current Fault 1 Short 1 Long F2 Low Voltage Warning 2 Short F3 Over Voltage Warning 3 Short F4 Over Temperature Warning 4 Short F5 Low Volts 5...

Page 12: ...e CAN port as well Ground A Output Power This module has both 10 amp and 4 amp outputs The outputs have both short circuit and overcurrent protection See Figure 1 2 10A 14 4A Reseting an output fault...

Page 13: ...oller Mode Output Reset Enabled 01 cycling the output will reset the fault if 00 power cycle required for fault reset Enable Status Msg 1 3 4 Enables the constant transmission of status message 1 Enab...

Page 14: ...hasn t been saved Status 7 9 13 Returns a value of 1 each time a Command message 52 58 is sent to ensure each configuration has been sent This is on for a brief moment and then resets Command 0x51 Out...

Page 15: ...amps for ports 5 6 Outputs 5A 5B 6A 6B Power 4 13 amps for ports 7 8 Outputs 7A 7B 8A 8B Ground B output ground internally connected to all Ground B pins Please note that ALL module power connections...

Page 16: ...ort 2 Pin 2 Output 2B Port 3 Pin 4 Output 3A Port 3 Pin 2 Output 3B Port 4 Pin 4 Output 4A Port 4 Pin 2 Output 4B Port 5 Pin 4 Output 5A Port 5 Pin 2 Output 5B Port 6 Pin 4 Output 6A Port 6 Pin 2 Outp...

Page 17: ...ables the constant transmission of status message 2 Enable Amp Msg 7 8 Enable the constant transmission of amperage message Enable 24 vdc 3 1 2 Enables the low and over voltage fault limits for 24 vdc...

Page 18: ...offset See PGN s used sheet Name Data Type Byte Bits Description Command Byte 1 Command for index pointer which message your sending Mode 1A 4 bit 2 1 2 3 4 Mode 0x0 disabled 0x1 On Off 0x2 Data 0 40...

Page 19: ...Description Command Byte 1 Command for index pointer Port 1A Output 1A 0 100 2 All Set amp range 0 0 10 0A Data Range 0 100 Port 1A Output 1B Not Used 3 Port 1A Output 2A 0 100 4 Port 1A Output 2B No...

Page 20: ...cated for each of the PWM control messages with the first 12 bits being used for the value The first byte and the first 4 bits of the second byte are put together for 12 bit control of the output Exam...

Page 21: ...K 7 Current reading on Output 4A 100mA bit OUT 4B AMP FEEDBACK 8 Current reading on Output 4B 100mA bit B Amperage Feedback Status Message 5 Ouput Amperage Feedback OUT 5A 8B Name Data Type Byte Bits...

Page 22: ...2 True when Message Command 0x52 received Status 10 3 4 True when Message Command 0x53 received Status 11 5 6 True when Message Command 0x54 received Status 12 7 8 True when Message Command 0x55 recei...

Page 23: ...lt Output 5A Status 5 1 2 Status of Output 5A 00 off 01 on 10 fault Output 5B Status 3 4 Status of Output 5B 00 off 01 on 10 fault Output 6A Status 5 6 Status of Output 6A 00 off 01 on 10 fault Output...

Page 24: ...A 4A All other outputs Outputs Port 1 Pin 4 Output 1A Port 1 Pin 2 Output 1B Port 2 Pin 4 Output 2A Port 2 Pin 2 Output 2B Port 3 Pin 4 Output 3A Port 3 Pin 2 Output 3B Port 4 Pin 4 Output 4A Port 4 P...

Page 25: ...18SA K004 CAN I O Port DT06 4S Wedgelock DT Series 4 pin Socket W4S Size 16 Solid Socket 16 20 AWG 0462 201 16141 Size 16 Solid Socket 14 AWG 0462 209 16141 Size 16 Locking Sealing Plug 114017 Art No...

Page 26: ...cle occurs set to 1 to write configuration to module 5 6 7 8 4 1 2 3 4 5 6 7 8 FREQ1 Word 5 Low Byte Sets the configuration of the frequency for all channels 30 1140 Hz value 0x 01 FE 6 High Byte MODE...

Page 27: ...tput7B 3 4 Output8A 5 6 Output8B 7 8 Byte 6 7 8 J1939 Output Control Control Message 1 Output Control J1939 Output Configuration 2 Command Value 81 0x51 Command Value 83 0x53 Name Data Type Byte Bits...

Page 28: ...8 Byte 3 4 5 6 7 8 J1939 Output Configuration 3 Transmit rate 50 ms Msg timeout 200 ms Priority 6 DP 0 PGN 61408 0xEFE0 Source Address 0x CSA PDU Format 239 0xEF PDU Specific 224 0xE0 Built Message 0...

Page 29: ...st 4 bits of the 2nd byte 8 1 2 3 4 Control Message 2 PWM1 Transmit rate 50 ms Msg timeout 200 ms Priority 3 DP 0 PGN 65309 0xFF1D Node offset of 0 Source Address 0x CSA PDU Format 255 0xFF PDU Specif...

Page 30: ...and the first 4 bits of the 2nd byte 8 1 2 3 4 PGN 65311 0xFF1F Node offset of 0 Source Address 0x CSA PDU Format 255 0xFF PDU Specific 31 0x1F Built Message 0x12FF1F Control Message 5 PWM4 Name Data...

Page 31: ...n Received Status 4 7 8 Node Alive Status 5 4 1 2 Node Fault Present Status 6 3 4 Fault Count not Zero Status 7 5 6 Status 8 7 8 Fault Code Byte 5 Active fault code User ID 6 The User ID of the module...

Page 32: ...t Output 4A Status 5 6 Status of Output 4A 00 off 01 on 10 fault Output 4B Status 7 8 Status of Output 4B 00 off 01 on 10 fault Output 5A Status 5 1 2 Status of Output 5A 00 off 01 on 10 fault Output...

Page 33: ...P FEEDBACK 3 Current reading on Port 2A 1mA per bit OUT 2B AMP FEEDBACK 4 Current reading on Port 2B 1mA per bit OUT 3A AMP FEEDBACK 5 Current reading on Port 3A 1mA per bit OUT 3B AMP FEEDBACK 6 Curr...

Page 34: ...0 4 000 0 4 000A OUT 6A AMP FEEDBACK 3 Current reading on Port 6A 0 4 000 0 4 000A OUT 6B AMP FEEDBACK 4 Current reading on Port 6B 0 4 000 0 4 000A OUT 7A AMP FEEDBACK 5 Current reading on Port 7A 0...

Page 35: ...40 FF41 EF CSA SA E7 FFFB SA E7 FFFC SA E7 FFF3 SA E7 FFF4 SA E7 FFE6 SA E7 8 EFE8 FF3C FF3D FF3E FF3F EF CSA SA E8 FFFB SA E8 FFFC SA E8 FFF3 SA E8 FFF4 SA E8 FFE6 SA E8 9 EFE9 FF40 FF41 FF42 FF43 EF...

Page 36: ...ield firmware updates with the use of the xtreme DB Programming Kit DP 34005 12 DP Loader is the software used to download the firmware to the xtreme DB blocks Please reference the DP Loader User Manu...

Page 37: ...A Murrelektronik Company 37 A Murrelektronik Company 1327 Northbrook Parkway Suite 460 Suwanee GA 30024 P 770 497 9292 F 770 497 9391 murrinc com DP34044 4 8 16 US xtremedb34044 4 2016...