P E T  F O U N T A I N

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

INSTALLATION INSTRUCTIONS FOR M-PM14 PET FOUNTAIN

Important:  Read  all  instructions  and  refer  to  local 
codes prior to installation.

l

Local  soil  conditions  may  require  more  gravel  for 
drainage.

l

It  is  recommended  to  include  a  supply  stop 
appropriate located on the supply line.

l

An  in-line  PRV  installed  on  the  supply  line  is 
recommended  to  ensure  a  working  water  pressure 
of 40-60 psi

l

A water filter should be installed on the supply line if 
sediment or mineral content is a problem.

l

 Supply line must be flushed of all foreign materials 
such as pipe dope, chips, etc.

l

  Piping  and  valve  must  be  drained  prior  to  being 
subjected to freezing temperatures.

Prepare trench for water supply lines and waste line (if 
required).  At  fountain  location  prepare  hole  to  trench 
depth  and  large  enough  for  a  person  to  work  in.  Lay 
supply  and  waste  into  trench  and  above  ground 
allowing extra line to be trimmed during hook up, refer 
to details for roughs.

Depending  on  code  and  design  requirements,  drain 
may  be  open,  French  or  sanitary  connection.  For 
French  drain,  place  a  minimum  of  three  cubic  feet  of 
gravel  under  drain  opening.  Local  soil  conditions  may 
require more gravel drainage.

Refill trench and hole, compacting back fill as required. 
Leave  sufficient  depth  in  hole  to  accommodate 
concrete pour, 4” minimum recommended.

Prepare slab area surrounding fountain spreading and 
compacting  gravel  as  necessary.  Prepare  form 
approximately 6” diameter to protect supply and waste 
stub outs. Protect exposed valve assembly, tubing and 
tube  openings  to  prevent  damage  to  equipment  or  to 
prevent  tubes  from  becoming  filled  with  soil  or  debris. 
Then pour concrete, ensure concrete is flat and level.

NOTE: FRENCH DRAIN SHOWN.

CONSULT LOCAL CODE

REQUIREMENTS.

4"

17"

REF

4" REC

MIN

ACCESS PANEL

2" PVC DWV DRAIN

PIPE RECOMMENDED,

BY OTHERS

FOR FREEZE RESISTANT
OPTION REFER TO -FRU
MANUAL #9938-340-0M1

VALVE SPECIFICATIONS:

MINIMUM/MAXIMUM PRESSURE:

30/100 PSI

LEVEL

HOSE BIBB w/ VACCUUM
BREAKER

HOSE HANGER

SUPPLY INLET CONNECTION
FOR 3/4" NPTM, BY OTHERS

1/2"-13 UNC MTG

HARDWARE,

PROVIDED

POURED

CONCRETE

GRAVEL

EARTH

MINIMUM 3 CUBIC

FEET OF POROUS

GRAVEL FILL

FROST LINE

WASTE CONNECTION

FOR Ø1-1/4" OD CLOSE

ELBOW, BY OTHERS

Please visit

 www.murdockmfg.com

 

for most current specifications.

 

M-PM14

Page 1 of 3

Revised: 

05/11/17

7020-204-001