background image

ECX

Ethernet Cable Extender 

INSTALLATION INSTRUCTIONS

7898 Zionsville Road 

 Indianapolis, Indiana 46268

Telephone: (317) 842-2545 

 www.mssedco.com 

 [email protected]

Page 1

(/MANU) ECXv0218

Section 1

General Description

The ECX Ethernet Cable Extender enables cable runs for 

the Intersector of up to 600 feet, doubling the allowable 

distance.

Section 2

Installation

LOCATION

For maximum protection against water and temperature 

extremes, locate the unit so that it is horizontal, shaded 

from direct sunlight, and sheltered from rainfall/direct 

immersion in water.  

MOUNTING PLATE

The optional mounting plate is attached to the unit using 

the two supplied tapping screws (spares included). It may 

be fitted in two orientations, for 4-bolt mounting or offset 

2-bold mounting, according to the space available. 

Mounting hardware is not included, as this is specific to 

each installation.  Both mounting options are shown 

below with a dimensioned template of the mounting 

plate:

FIGURE 1

CONNECTOR ASSEMBLY

IMPORTANT: 

Please follow the procedure below 

 

carefully to ensure the best seal:

 

1.  Fit a standard RJ45 plug to the network cable.

 

2.  Thread the cable through the outer cap A.

 

3.  Fit the split rubber grommet B over the cable.

 

4.  Thread the cable through the inner cap C.

FIGURE 2

ASSEMBLING THE CONNECTOR

 

5.  Fit the rubber washer D to the OUTREACH 

 

 

connector, with the flat side facing inwards

 

6.   Plug the RJ45 connector on the cable into 

 

 

the OUTREACH

 

7.   Holding the OUTREACH, screw the inner 

 

 

cap C onto the OUTREACH connector and 

 

 

tighten firmly.  Tightening the inner cap C 

 

 

before fitting the outer cap A prevents the 

 

 

cable from twisting

 

8.   Push in the grommet B and screw the outer 

 

 

cap A tight.  the cable is sealed when 

 

 

the grommet B bulges to the edge of the 

 

 

outer cap A

If the connector has to be removed:

 

1.   Holding the inner cap C, fully unscrew the 

 

 

outer cap A

 

2.   Unscrew the inner cap C. Try to prevent the nut 

 

 

on the connector from unscrewing with it

 

3.   Check the connector nut and re-tighten if 

  necessary

 

4.   Check that the rubber washer D has not 

 

 

become stretched due to overtightening

 

5.   Ensure all parts are dry before reassembly

Connect the ECX to the TCIB and Intersector as show in 

Figure 3 (on page 2).

Section 3

Technical Data

Model............................................... ECX

Temperature Rating........................ -40°F to 140°F 

 

(-40°C to 60°C)

Environmental Rating..................... IP66

Mounting plate thickness: 2mm

Reviews: