Section 1 

General Description 

The  216  Series  "touchless"  switches  are  active  infrared 

devices  designed  for  hands-free  activation  of  automatic 

door operators or other access control products.  The 216 

switch  assembly  will  fit  in  a  variety  of  locations  from  a     

1  3/4"  door  frame  to  a  single  or  2-gang  or  junction  

electrical box.  Various size surface mounting boxes are 

also available from the factory.  Three standard face plate 

sizes are available: 

  216: 

4 1/2" x 4 1/2" stainless steel (fits single, 2- 

   

gang, junction electrical boxes) 

  216-L:  2 3/4" x 4 1/2" stainless steel (fits single gang  

   

electrical boxes) 

  216-N:  1 11/16" x 4 1/2" stainless steel (fits 1 3/4"  

   

door frames)  

 

 

Section 2 

Basic Installation 

SINGLE GANG ELECTRICAL BOX:  216 & 216-L 

1)  Install the electrical box (purchased separately) in its  

  intended location. 

2)  Set the unit for its intended operating mode via the  

  jumpers on the side of the switch assembly:  Fail  

  Close (factory setting), Fail Open or Toggle (Figure 1). 

3)  Make the appropriate electrical connections to the  

  switch assembly--4 wires are required (Figure 2). 

4)  Attach the switch assembly to the electrical box with  

  the two (2) 6-32 x 1/2" screws provided. 

5)  Adjust for range and time delay via the potentiometers  

  on the front of the switch assembly (Figure 3). 

6)  Attach face plate with the 6-32 x 3/8" screws provided  

  ensuring that the backside of the face plate lens and  

  the foam gasket on the front of the switch assembly  

  are less than 1/4" apart (Figure 4). 

 

2-GANG ELECTRICAL BOX OR JUNCTION BOX:  216  

1)  Install the electrical box (purchased separately) in its  

  intended location. 

2)  Attach the adaptor ring provided (see below) to the  

  electrical box. 

 

 

  

 

 

 

 

 

 

3)  Set the unit for its intended operating mode via the  

  jumpers on the side of the switch assembly:  Fail  

  Close (factory setting), Fail Open or Toggle (Figure 1). 

4)  Make the appropriate electrical connections to the  

  switch assembly--4 wires are required (Figure 2). 

5)  Attach the switch assembly to the adaptor ring  

  (mounted to the electrical box in step 2) with the 6-32  

  x 1/2" screws provided. 

6)  Adjust for range and time delay via the potentiometers  

  on the front of the switch assembly (Figure 3). 

7)  Attach face plate with the 6-32 x 3/8" screws provided  

  ensuring that the backside of the face plate lens and  

  the foam gasket on the front of the switch assembly  

  are less than 1/4" apart (Figure 4). 

 

DOOR FRAME:  216-N 

1)  Make a cutout in the door frame at the intended  

  location.  Drill and tap 2 mounting holes (see below). 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2)  Set the unit for its intended operating mode via the  

  jumpers on the side of the switch assembly:  Fail  

  Close (factory setting), Fail Open or Toggle (Figure 1). 

3)  Make the appropriate electrical connections to the  

  switch assembly--4 wires are required (Figure 2). 

4)  Mount the switch assembly in the cutout and attach  

  with the 6-32 x 1/2" screws provided. 

5)  Adjust for range and time delay via the potentiometers  

  on the front of the switch assembly (Figure 3). 

6)  Attach face plate with the 6-32 x 3/8" screws provided  

  ensuring that the backside of the face plate lens and  

  the foam gasket on the front of the switch assembly  

  are less than 1/4" apart (Figure 4). 

 

1 3/8" 

3 1/4" 

2 7/8" 

11/16" 

DRILL & TAP 

6-32 (2 Holes) 

Summary of Contents for 216

Page 1: ... and the foam gasket on the front of the switch assembly are less than 1 4 apart Figure 4 2 GANG ELECTRICAL BOX OR JUNCTION BOX 216 1 Install the electrical box purchased separately in its intended location 2 Attach the adaptor ring provided see below to the electrical box 3 Set the unit for its intended operating mode via the jumpers on the side of the switch assembly Fail Close factory setting F...

Page 2: ...on Unless MS SEDCO is notified of the date of installation the warranty will be in effect for 1 year from the date of shipment from our factory If during the first year our motion detector or support device fails to operate and has not been tampered with our abused the unit can be returned prepaid to factory and it will be repaired free of charge After 1 year the unit will be repaired for a nomina...

Page 3: ...ctivated again returning the relay to its de energized state For example a 216 series switch could be located at the entrance of a room When a person enters the 216 series switch turns on the light As they exit the 216 series switch turns off the light In order to program this mode cut Jumper 2 Wire connections are COM and N O Input Connections Output Connections 12 24V AC or DC Green Common COM R...

Page 4: ...e lens and foam gasket should be touching WARNING When attaching the face plate to the switch assembly only use 6 32 x 3 8 screws provided Use of longer screws may cause damage to the unit Range Adjustment Clockwise to increase 6 to 30 NOTE When attaching the face plate the range may increase Reaction Time Adjustment Clockwise to increase 0 05 to 1 second SIDE VIEW REACTION TIME 0 05 1 Sec INC RAN...

Reviews: