Page 1: ...mr steam Feel Good Inc Installation Operation and Maintenance Manual Steambath Generator Systems Residential Models MS90E MS400E and MSSUPER1E 6E ...

Page 2: ...the time of publication Sussman Automatic Corporation reserves the right to make changes at any time without notice When installing and using this electrical equipment basic safety precautions should always be followed including the following IMPORTANT SAFETY INSTRUCTIONS 1 READ AND FOLLOW ALL INSTRUCTIONS 2 DO NOT permit children under the age of 16 to use this steambath 3 Steam is hot and can ca...

Page 3: ...ion 7 Steam Generator Dimensions 8 Electrical Specifications Field Power Wiring 9 Wiring Diagrams 10 11 Optional Tandem Cable Diagram 11 Initial Start Up Checkout 12 Optional Accessary Equipment 12 Troubleshooting 12 System Status Codes 13 Liquid Level Control Board 13 Optional AutoFlush System 14 Optional Drip Pan 15 Optional Express Steam 15 Parts Identification Diagrams 16 Replacement Parts Lis...

Page 4: ... 5 21 10 100 0 67 14 L x 14 H x 6 D 30 MS150E 6 25 8 150 0 80 14 L x 14 H x 6 D 30 MS225E 7 5 32 8 225 1 0 14 L x 14 H x 6 D 30 MS400E 9 38 8 360 1 2 14 L x 14 H x 6 D 30 MS SUPER 1E 10 42 8 475 1 4 17 L x 18 H x 77 8 D 40 MS SUPER 2E 12 50 6 575 1 6 17 L x 18 H x 77 8 D 40 MS SUPER 3E 15 63 4 675 2 0 17 L x 18 H x 77 8 D 40 MS SUPER 4E 20 84 8 875 2 7 17 L x 18 H x 77 8 D x 2 80 MS SUPER 5E 24 10...

Page 5: ...the Steam Generator and packaging for shipping damage In the event of shipping damage please contact the carrier for claim information Our customer service department can assist you with any missing or damaged parts Read these instructions before installation or service Although this MS steambath generator has been fully quali fied for shipment by MrSteam the following must be reviewed for proper ...

Page 6: ... as required for servicing See page 8 10 Provide unions as required to facilitate installation and disconnection of piping 11 MrSteam controls can be located inside the steam room or on the outside of the steam room See the Control Installation Manual for your specific control package for specific details 12 The MS series of steam generators are for residential use only Commercial or other nonresi...

Page 7: ...ge 14 Steam Heads shown with optional acrylic shields Water Feed Line Power Supply NOTE Drawings for illustrative purposes only Consult with qualified designer architect or contractor for steam room construction details Provide unions as required to facilitate installation and disconnect of piping Steam Generator Field installed power supply Field installed steam supply pipe Drain Valve must be cl...

Page 8: ... in accordance with applicable National and local codes 1 Use unions on all pipe connections 2 Use only brass piping or rigid copper tubing as permitted by codes 3 DO NOT use black galvanized PVC pipe or PEX except as noted below WATER SUPPLY 3 8 NPT 1 Connect to cold water line NOTE Water feed line may be flexible copper tubing braided hose PVC or PEX if permissible by local codes 2 Provide a shu...

Page 9: ...ect a brass nipple of that length to finish the installation STEP 5 Wrap teflon tape around the threads of the new nipple and screw the nipple into the steamhead Do not use wrenches or tools which would damage the steamhead s finish Wrap teflon tape around the threads of the nipple and screw the nipple and steamhead assem bly you just made into the drop ear fitting in the wall The steam head shoul...

Page 10: ...es 2 MS Super 2E units 5 MS Super 6E includes 2 MS Super 3E units J Water Inlet Control Accessory Connections Steam Outlet Safety Valve Optional AutoFlush IMPORTANT NOTES Provide a minimum of 12 inches at both ends and top of the steam generator or as required for servicing Alternately provide unions as required to facilitate installation and dis connection of the steam generator The minimum clear...

Page 11: ...e wire is not required ELECTRICAL CHART ________________________________________________________________________________________________________ Vol Max Room Wire Size Wire Size Model No Cu Ft KW Volts Phase Amps AWG for 40 C AWG for 45 C Ambient Ambient ____________________________________________________________ ____________________________________________ 208 1 24 10 8 MS 90E 100 5 0 3 14 12 12...

Page 12: ...ID VALVE FUSES POWER INPUT TRANSFORMER CONTROL BOARD CONTACTOR GROUND HEATING ELEMENT TO PROBE WATER FEED SOLENOID VALVE AutoFlush optional SteamGenie or iGenie optional iSteam AirTempo iTempo Plus or iTempo Control SINGLE PHASE 208 240 VOLT WIRING DIAGRAMS THREE PHASE 208 240 VOLT WIRING DIAGRAM MODELS MS90E MS150E MS225E MS400E MODELS MS SUPER 1E MS SUPER 2E MS SUPER 3E Note Super 1E 240V does n...

Page 13: ...d as shown 5 Connect separate plumbing and power supplies for each unit Wiring Diagram MS Super 4E MS Super 5E MS Super 6E AutoFlush optional iTempo Start optional iSteam AirTempo or iTempo Plus AutoFlush optional Do Not Connect Control FACTORY WIRING FIELD WIRING L E G E N D All Diagrams CONTACTOR PRIMARY UNIT SECONDARY UNIT AutoFlush optional Steam Genie optional iSteam AirTempo or iTempo Plus A...

Page 14: ...egin to appear in approximately 5 minutes unless equipped with factory installed Express Steam option at the steam head Steam will shut off when desired temperature is reached and will automatically resume when room temperature drops below set point 3 Steam will shut off automatically when control counts down to zero To shut steam off manually turn control OFF To clear steam from enclosure area tu...

Page 15: ...ns LIQUID LEVEL CONTROL BOARD Explanation of LED Indicators ______________________________________________________________________________________________________________________________________ GREEN LED is ON when there is 208 240 Volt incoming power connected 24 Volt transformer secondary output and on board 5 Volt DC control power are present ___________________________________________________...

Page 16: ...in connector as shown DO NOT drain into a steam enclosure or any location where accidental contact with drain water may occur In the event of a power failure the AutoFlush System valve will open and may dis charge boiling water causing a scalding hazard SWEAT FITTINGS When using sweat fittings use only tin base solder with a melting point below 600 degrees F DO NOT overheat Ends of water supply tu...

Page 17: ...ip pan is equipped with an integral female 3 4 NPT fitting NOTE Do not plumb the generator drain and drip pan drain together in such a way that will cause drain water to back into drip pan OPTIONAL EXPRESS STEAM only available factory installed Available for all MS Models Express Steam genera tors are equipped with a low power heating element and thermostat to keep the water in the tank warm enoug...

Page 18: ...entification MS SUPER MODELS MS SUPER 1E MS SUPER 6E with AutoFlush shown with cover removed NOTE Super 1E 240 1 models are not supplied with internal fusing NOTE FOR ILLUSTRATIVE PURPOSES ONLY Some components may be omitted or altered for clarity DO NOT use for wiring repair or other purposes not related to component identification Transformer Drain Line Nipple not included Liquid Level Control B...

Page 19: ...2 Probe Assembly All Models 99096MS Heating Element Gasket All Models 103938 Round Acrylic Shield iTempo iTempo Plus All Models 103938 Square Acrylic Shield iTempo iTempo Plus All Models 99314 Power Fuse 60A 250V MS Super 1E 6E Single phase 29051BMS Heating Element 5 KW 208V MS 90E 29051CMS Heating Element 5 KW 240V MS 90E 29061BMS Heating Element 6 KW 208V MS 150E 29061CMS Heating Element 6 KW 24...

Page 20: ...Plus iTempo HomeWizard or iGenie controls without reading and understanding its own manual and the MrSteam steam generator Installation and Operation Manual Failure to read and understand these instructions may result in an inoperative or hazardous installation A peel and stick warning sticker must be read and permanently affixed in a conspicuous location near the steam room Failure to read and af...

Page 21: ...DO NOT permit children under the age of 16 to use this steambath 3 Steam is hot and can cause injury or death if improperly used Steam rooms contain steam and elevated tempera tures Please read and observe all warnings in this manual before installing or using a steam room 4 To reduce the risk of injury A The wet surfaces of steam enclosures may be slippery Use care when entering or leaving B The ...

Page 22: ...l preference however it is highly rec ommended to begin steam bathing at a low temperature setting to gauge comfort and safety levels Set duration to a maximum of 10 minutes to gauge comfort and safety levels This will allow the steam generator to heat up and begin producing steam SAFETY AND OPERATING INFORMATION DO NOT install or use any iSteam AirTempo iTempo Plus iTempo HomeWizard or iGenie con...

Page 23: ...ritants Use essential oils with caution 2 Place the drops into the MrSteam AromaSteam steamhead recess prior to turning on the steambath DO NOT place drops in a hot steam head as serous injury can result if you do not follow this warning 3 Start with one drop to gauge strength and suitability Limit to a maximum of a few drops for a steambathing session 4 The bather should exit the steambath IMMEDI...

Page 24: ...Spa HomeWizard iButler iGenie iSizing iSteam iTempo iTempo Plus Making Wellness a Way of Life Music Therapy Spa Package Steam Genie Steam on Demand Steam Home SmartSizing SteamStart SteamStop SteamTherapy Sussman Tala The Intelligent Steambath Valet Package Virtual Spa System Voice Genie and Voice Wizard are registered trademarks of Sussman Automatic Corporation PUR 100472A 1 17 Products informati...