NPort 4511

 

Hardware Installation Guide 

Third Edition, June 2008 

www.moxa.com/product

   

 

 

©

 2008 Moxa Inc., all rights reserved. 

Reproduction without permission is prohibited. 

Summary of Contents for NPort 4511

Page 1: ...NPort 4511 Hardware Installation Guide Third Edition June 2008 www moxa com product 2008 Moxa Inc all rights reserved Reproduction without permission is prohibited ...

Page 2: ...t on the part of Moxa Moxa provides this document as is without warranty of any kind either expressed or implied including but not limited to its particular purpose Moxa reserves the right to make improvements and or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However ...

Page 3: ...as Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 10 6872 3958 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 ...

Page 4: ...Status Check 2 1 3 Ethernet Installation 3 1 Connecting to a Hub or Switch 3 1 Connecting to a PC 3 2 4 Serial Port Installation 4 1 RS 232 Pinouts and Loopback Tester 4 1 RS 422 485 Pinouts and RS 422 Loopback Tester 4 2 Loopback Header 4 3 Mini Adapter 4 3 Terminal Block 4 4 5 Operation Mode Settings 5 1 DIP Switch Settings 5 1 Operation Mode Introduction 5 2 Developing Mode 5 2 Running Mode 5 2...

Page 5: ...ble second stage platform for System Integrators SI or large scale customers to develop their own communication gateway functions and user interface The typical Communication Gateway CG is a special purpose server used to transform between the serial and Ethernet interfaces Communication Gateways have one or more Ethernet port and one or more serial port and are commonly referred to as serial to E...

Page 6: ...rface Convenient cigarette pack size for easy integration SDK Utility convenient configuration debug download utility Supports easy development platforms Turbo C 2 x Borland C 3 x SDK Library that supports more than 100 function calls 64 KB of memory for program and data space 32 KB Flash ROM for data storage Product Specifications Hardware Processor 16 bit CPU Memory 512 KB DRAM 512K Flash Connec...

Page 7: ...ing Platforms Supported Windows XP 2000 NT Windows 95 98 Me Operation Modes Developing Mode Running Mode Power and Environment Power requirements 9 to 30 VDC 300 mA max at 9V 100 to 240 VAC switching power adapter included 12 VDC 400 mA Operating temp 0 55 C Operating humidity 5 95 RH Dimensions W D H including ears 90 100 4 22 mm 3 54 3 95 0 87 in without ears 67 100 4 22 mm 2 64 3 95 08 7 in Gro...

Page 8: ...Guide NPort PCG Programmer s Guide NPort PCG API Reference Optional Accessories Power Adapter 100 240 VAC to 12 VDC 400 mA switching power adapter Cable 150 cm DB9 Male to DB9 Female serial cable 100 cm Ethernet cross over cable Connector RS 232 Loopback testing header DB9 Male to Terminal Block connector DB9 Male mini adapter DIN Rail mounting kit For 35 mm DIN Rail includes 4 screws Miscellaneou...

Page 9: ...ress continuously for a 3 sec to erase the password After 3 sec the ready LED will flash on off every half second Release the reset button at this time to erase password b 10 sec to load factory defaults After 10 sec the ready LED will flash on off every fifth of a second Release the reset button at this time to load factory defaults 1 5 ...

Page 10: ...ED Name LED Color LED Function red Power is on PWR off Power is off or power error condition exists orange 10 Mbps Ethernet connection green 100 Mbps Ethernet connection Link off Ethernet cable is disconnected or has a short green NPort 4511 system is ready Ready off NPort 4511 has malfunctioned if PWR LED is on 1 6 ...

Page 11: ...DIN Rail mount STEP 3 Push the bottom of NPort 4511 so that the bottom of the DIN Rail snaps into the bottom slot of the DIN Rail mount NOTE The DIN Rail mounting kit is an optional accessory To remove NPort 4511 from the DIN Rail simply reverse Steps 2 and 3 above by grasping the bottom of the NPort 4511 unit with both hands and then using your fingers to pull down slightly on the bottom DIN Rail...

Page 12: ...he shafts should be no greater than 3 mm in diameter Do not screw the screws in all the way leave a space of about 2 mm to allow room for sliding the NPort 4511 unit s ears between the wall and the screws STEP 2 Insert the two screw heads through the large parts of the keyhole shaped apertures and then slide NPort 4511 downwards as indicated STEP 3 For added stability simply tighten the two screws...

Page 13: ...there is no on off switch The server turns on as soon as the connected power adapter is plugged into a live outlet The red PWR light on NPort 4511 s top panel will glow to indicate that it is receiving power Power Status Check Use the PWR LED on NPort 4511 s top panel to see if it is receiving power A red light indicates that power is being received The absence of a light indicates that power is n...

Page 14: ...ill simply plug one end of your Ethernet cable into NPort 4511 s 10 100BaseTX port and the other end into a Hub or Switch that is connected to your network In this case you should use a standard straight through Ethernet cable which is readily available from many commercial vendors However if necessary you can make your own cable by referring to the following cable wiring diagram ...

Page 15: ...re you may find it convenient to connect NPort 4511 directly to your computer s Ethernet card To do this you will need to use a cross over Ethernet cable This type of Ethernet cable is harder to find although you can make your own cable by referring to the following cable wiring diagram 3 2 ...

Page 16: ...ation In this chapter we give the DB9 Female Connector Pinouts The following topics are discussed RS 232 Pinouts and Loopback Tester RS 422 485 Pinouts and RS 422 Loopback Tester Mini Adapter RS 232 Pinouts and Loopback Tester ...

Page 17: ...RS 422 485 Pinouts and RS 422 Loopback Tester 4 2 ...

Page 18: ...ack Tester section above for the wiring diagram Mini Adapter NPort 4511 was designed with a built in D shell female serial connector which most serial devices also have In order to make it easier for our customers to attach NPort 4511 to any serial device a DB9 male to DB9 male mini null modem adapter is included as a standard accessory with NPort 4511 Null Modem Adapter Null Modem Adapter and NPo...

Page 19: ...nal block has a Male DB9 connector that can be used in conjunction with the mini adapter to connect directly to NPort 4511 note that the terminal block is wired pin to pin Another alternative is to use the Male DB9 to Female DB9 cable included as a standard accessory to easily connect NPort 4511 to the terminal block as shown below 4 4 ...

Page 20: ...le Communication Gateway Programmer s Guide and NPort PCG API Reference for information on how to develop your NPort 4511 program In this chapter we discuss the following topics related to NPort 4511 s operation DIP Switch Settings Operation Mode Introduction Developing Mode Running Mode DIP Switch Settings The top panel of NPort 4511 contains the following table which shows how DIP switch 1 SW1 i...

Page 21: ...NPort 4511 is in Developing Mode Run Stop NPort 4511 s program manually for testing and debugging Configure NPort 4511 Download a program Monitor program behavior Upgrade firmware Running Mode Running Mode is used during NPort 4511 s normal operation The following functions are available when NPort 4511 is in Running Mode Activate a program automatically after NPort 4511 is powered on Configure NP...

Page 22: ...me Programmable Communication Gateway Model Number NPort 4511 EMC FCC Class B EN55022 1998 class B EN61000 3 2 1995 class B EN61000 3 3 1995 EN55082 1 1997EN61000 4 2 1995 Contact Discharge 4 KV Air Discharge 8 KV EN61000 4 3 1995 EN61000 4 4 1995 AC DC Power supply 1 KV Data Signal lines 5 KV EN61000 4 5 1995 AC DC Line to Line 1 KV AC DC Line to Earth 2 KV EN61000 4 6 1995 EN61000 4 8 1993 3 A m...

Page 23: ...ative or dealer Fill out the Problem Report Form PRF Include as much detail as possible for a shorter product repair time Carefully pack the product in an anti static package and send it pre paid to the dealer The PRA should be visible on the outside of the package and include a description of the problem along with the return address and telephone number of a technical contact ...

Page 24: ...85 ADDC 3 Serial Number __________________________ 4 NPort Firmware Version __________________ 5 NPort Manager Version ___________________ 6 PC Host Make ______________________ Model ______________________ 7 Problem Description Please describe the symptoms as clearly as possible including all error messages Be complete since we may need to follow your description to reproduce the symptoms ...