Table of Contents

Model Parts-------------------------------------------------------------2

Natural Gas Conversion ---------------------------------------------3

Natural Gas Conversion For Model 41847NG --- -----------4-7

Natural Gas Conversion For Model 77352NG --------------8-11

Gas Leak Checking---------------------------------------------------12

Product Registration Card-------------------------------------------13

C043100-A2

Warranty

One-Year Full Warranty on Part

If this part fails due to defective material or workmanship within 

one year from the date of purchase, call 1-888-980-4933 to 

arrange for a free repair (or replacement if repair proves 

impossible) 

Summary of Contents for 98523

Page 1: ...For Model 41847NG 4 7 Natural Gas Conversion For Model 77352NG 8 11 Gas Leak Checking 12 Product Registration Card 13 C043100 A2 Warranty One Year Full Warranty on Part If this part fails due to defective material or workmanship within one year from the date of purchase call 1 888 980 4933 to arrange for a free repair or replacement if repair proves impossible ...

Page 2: ...or A02120848 Model 98523 Parts 6mm Orifice Sockets A02120844 Slot Screwdriver A02120843 2 Reminder Please keep the main burner brass LP orifices Side Burner Orifice and original LP regulator just in case you wish to change back from NG to Propane ...

Page 3: ...cause serious bodily injury death or property damage Leaks due to improper conversion could occur immediately or slowly over time If you hear any unusual noises or leaks smell gas or unusual odors or notice anything unusual with the operation of your gas appliance after the installation immediately shut off the gas supply and discontinue use until the appliance is repaired by a QUALIFIED GAS TECHN...

Page 4: ... LP regulator from the manifold GAS CONVERSION FOR MODEL 41847NG Reminder Please keep the original LP regulator Just in case you want to change back from NG to Propane 6 Use an adjustable wrench to install the Natural gas regulator hose to the manifold and secure 4 Label position 7 After LP is converted to NG you need to put a label on the location shown below Just in case you want to change back ...

Page 5: ...exible gas supply hose to the Natural gas pressure regulator Make Gas Connection FOR MODEL 41847NG PS IG G LO B A L Q C LO W PS IG G LO BA L Q C L O W 3 Connect the quick connector on the other end of the 10 ft 3 0 m PVC flexible gas supply hose to the rigid Natural gas supply pipe 4 Please do leak test after conversion 5 ...

Page 6: ...he burner in place the clamp spring will drop off to grease tray or grill cart 3 Remove the burner from the grill by lifting the burner out 6 Reinsert the burner and reattach using the Clamp Spring previously removed Repeat the procedure for each main burner 6 5 The NG orifice is pre installed in grill That is NG origfice after your remove the LP orifice Reminder Please keep the LP orifices Just i...

Page 7: ...vidual bag marked for NG gas conversion only Reminder Please keep the LP Side Burner Orifice Just in case you want to change back from NG to Propane 2 Use a flat blade screwdriver to turn the high flame setscrew clockwise approximate 90º 4 Replace the control knob and turn off the burner 3 Check that burner operates at the new high flame setting It may be necessary to adjust the screw setting slig...

Page 8: ...egulator from the manifold GAS CONVERSIONS FOR MODEL 77352NG Reminder Please keep the original LP regulator Just in case you want to change back from NG to Propane 6 Use an adjustable wrench to install the Natural gas regulator hose to the manifold and secure 8 Label position 7 After LP is converted to NG you need to put a NG spec label on the location shown above Just in case you want to change b...

Page 9: ...xible gas supply hose to the Natural gas pressure regulator Make Gas Connection FOR MODEL 77352NG 3 Connect the quick connector on the other end of the 10 ft 3 0 m PVC flexible gas supply hose to the rigid Natural gas supply pipe 4 Please do leak test after conversion 9 PS I G G LO B A L Q C L O W PS IG G LO B AL Q C LO W ...

Page 10: ...he burner in place the clamp spring will drop off to grease tray or grill cart 3 Remove the burner from the grill by lifting the burner out 6 Reinsert the burner and reattach using the Clamp Spring previously removed Repeat the procedure for each main burner 10 5 The NG orifice is pre installed in grill That is NG origfice after your remove the LP orifice Reminder Please keep the LP orifices Just ...

Page 11: ...dual bag marked for NG gas conversion only Reminder Please keep the LP Side Burner Orifice Just in case you want to change back from NG to Propane 2 Use a flat blade screwdriver to turn the high flame setscrew clockwise approximate 90º 4 Replace the control knob and turn off the burner 3 Check that burner operates at the new high flame setting It may be necessary to adjust the screw setting slight...

Page 12: ...1 2 3 50 50 4 A soap Procedures for gas leaks checking 4 B 12 ...

Page 13: ...ast name ______________ First Name _______________ Address _______________City _________ State _______ 13 Zip ____________ Phone __________ Email ______________ Place of purchase ___________ Model Number ___________ Serial Number _____ Date of Purchase ___________ Please return your Product Registration Card today to validate the warranty service ...