background image

xg0207 - 170223

Installation & Maintenance Manual

•  The installation of this fireplace must be done by a 

qualified and certified gas appliance installer.

•  Check local codes and read all instructions prior to 

installation.

®

C

US

       WARNING:

FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious injury, 

death, or property damage.

— Do not store or use gasoline or other flammable vapors and 

liquids in the vicinity of this or any other appliance.

— WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.
•  Do not touch any electrical switch; do not use any 

phone in your building.

•  Leave the building immediately.
•  Immediately call your gas supplier from a neighbour's 

phone. Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

— Installation and service must be performed by a qualified 

installer, service agency or the gas fitter.

Divine See-Through

  

INDOOR GAS FIREPLAcE

H38FSDN 

Natural Gas

H38FSDL 

Propane Gas

H38FSDNI 

Natural Gas

H38FSDLI 

Propane Gas

Read and understand this manual. Improper installation, adjustment, 

alteration, service or maintenance can cause serious injury, property 

damage or even death. For assistance or additional information 

consult a qualified installer, service agency or the gas supplier.

A barrier designed to reduce the risk of burns from the 

hot viewing glass is provided with this appliance and 

must be installed for the protection of children and 

other at-risk individuals.

HOT GLASS

 wIll  

cAuse buRns.

DO NOT TOUcH

 glAss  

untIl cooled.

NEvER

 Allow chIldRen  

to touch glAss.

Installation and service must be performed by a qualified installer, 

service agency or the gas fitter.

Installer:

 leave this manual with the appliance.

consumer: 

Retain this manual for suture reference.

Notice

cautioN

DaNger

DaNger

H42FSDN 

Natural Gas

H42FSDL 

Propane Gas

H42FSDNI 

Natural Gas

H42FSDLI 

Propane Gas

some materials used in the manufacturing process of this product can 

expose you to benzene which is known in the state of california to 

cause cancer and birth defects or other reproductive harm. For more 

information go to www.P65warnings.ca.gov

WarNiNg

Summary of Contents for Divine See-Through H42FSDL

Page 1: ...L Propane Gas H38FSDNI Natural Gas H38FSDLI Propane Gas Read and understand this manual Improper installation adjustment alteration service or maintenance can cause serious injury property damage or even death For assistance or additional information consult a qualified installer service agency or the gas supplier A barrier designed to reduce the risk of burns from the hot viewing glass is provide...

Page 2: ...allation Information See Appendix B The Montigo warranty will be voided by and Montigo disclaims any responsibility for the following actions Modification of the fireplace and or components including Direct Vent assembly or glass doors Use of any component part not manufactured or approved by Montigo in combination with this Montigo fireplace system Installation other than as instructed in this ma...

Page 3: ...ing 24 Mantels Surrounds 24 Fireplace Facing 24 Finishing around the fireplace 24 Section 7 Screen Installation and Removal 25 Removing the Screen 25 To Install Screens 25 Replacement Screens 25 Section 8 Installing Removing the Door 26 Removing the door 26 Section 9 Installing the Accessories 27 H38ST Installing the Logs and Embers 27 H42ST Installing the Logs and Embers 27 Linear Conv Installing...

Page 4: ...alinstallations mustconformtothelocalcodesor intheabsenceoflocalcodes to the current version of Canadian Electrical Code CSA C22 1 1 Installations in the USA must conform to the local codes or in the absence of local codes to the current version of National Fuel Gas Code ANSI Z223 1 NFPA 54 Electrical installations must conform to the local codes or in the absence of local codes to the current ver...

Page 5: ...ace maintaining proper clearance Firestops installed Exteriorwall roofflashinginstalledandsealedincompliancewithlocalbuildingcode Terminations installed and sealed in compliance with local building code Direct vent termination is highest point in vent assembly Wiring Electrical Section 4 Unswitched power provided to the appliance PPO box Low voltage wire connected to dry contact wall switch non po...

Page 6: ... Sample Figure 1 1 Rating Plate for standing pilot SIT Figure 1 2 Rating Plate for IPI electronic ignition LBL1205 V6 1 Stand Pilot Screen DEC06 2014 Teklynx LabelView Demo LB1223 V5 1 SIT IPI with screen DEC06 2014 Teklynx LabelView Demo ...

Page 7: ... 43 5 16 640 25 3 16 927 36 1 2 1030 40 9 16 175 6 7 8 927 36 1 2 127 5 203 8 959 37 3 4 305 12 610 24 HS38DF ST DIMENSIONS TOLERANCES ARE IN METRIC MM 1 6 MM IMPERIAL FRACTIONAL 1 16 THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CANADIAN HEATING PRODUCTS ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CANADIAN HEATING PRODUCTS IS PROHIBITED PROPRIETARY...

Page 8: ...r shelves over the fireplace Top vent Figure 3 b Combustible Framing for shelves over the fireplace Side vent Figure 3 b Non Combustible Framing with alcove above fireplace Right side Combustible Framing above fireplace Left side see figure 2 Top Vent A b c d e H38DFST 40 42 N A 23 40 H42DFST 45 49 46 24 45 1 Min Non combustible nailing flange supplied Both sides typical Non combustible materials ...

Page 9: ...ons the minimum clearance is 2 from the Side of the fireplace to a wall and 12 clearance from the top of the fireplace to the underside of any combustible shelf materials For Top Vent applications the minimum clearance is 2 from the Side of the fireplace to a wall and 19 to the underside of any combustible shelf materials 1 clearance is maintained on sides and bottom of vent runs and 2 above horiz...

Page 10: ... the termination location has been established refer to the appropriate section below for installation details All fireplaces shipped from the factory are top vent Silicone application is NOT required when joining Montigo vent pipes and components Section 3 1 Converting to Side Vent Use the following instructions to convert a unit for side vent use Remove the Side flue cover and gasket 5 and 8 on ...

Page 11: ...st be a minimum 18 from a parapet wall For a more detailed diagram of allowed termination locations see Appendix A A maximum of two offsets each offset is made up of 2 90 bends may be made for vertical vent runs Firestops must be installed as required by National local codes Ensure all horizontal runs are supported with a minimum of 3 supports per 10 of venting Install all roof flashing and storm ...

Page 12: ...lation xg0207 170223 Figure 6 d Side vent Roof mounted venting 1 90 bend Storm collar Support plate 32 max Roof flashing MVTK1 Termination Support ring PEXT Solid Sections 2 min 12 max Firestop Firestop 90 Elbow ...

Page 13: ... the interior side of the studs concrete or finished wall construction using a minimum of 4 screws 3 Insert the termination into the MOSR frame as shown here from the inside and attach to the MOSR by installing a min quantity of 4 bolts into the threaded nuts on the MOSR Frame Installation of termination frame at time of framing in masonry Terminations with a BSR frame allow the installation of th...

Page 14: ...l flange of the termination Plot on the Venting Graph with an X If the X falls on or above the top boundary of the shaded area the installation is acceptable h38dfST top vent run Example A Acceptable Installation If the vertical dimension from the hearth is 114 and the horizontal run to the wall flange of the vent termination is 168 this would be an acceptable installation Example B Unacceptable I...

Page 15: ...al dimension from the hearth is 48 and the horizontal run to the wall flange of the vent termination is 96 this would not be an acceptable installation Example C Unacceptable Installation If the vertical dimension from the floor of the fireplace is 72 and the horizontal run to the wall flange of the vent termination is 120 this would not be an acceptable installation Side Venting Graph Measure the...

Page 16: ...rmination Plot on the Venting Graph with an X If the X falls on or above the top boundary of the shaded area the installation is acceptable h42dfST top vent run Example A Acceptable Installation If the vertical dimension from the hearth is 120 and the horizontal run to the wall flange of the vent termination is 138 this would be an acceptable installation Example B Unacceptable Installation If the...

Page 17: ...nstallation If the vertical dimension from the hearth is 48 and the horizontal run to the wall flange of the vent termination is 96 this would not be an acceptable installation Example C Unacceptable Installation If the vertical dimension from the floor of the fireplace is 72 and the horizontal run to the wall flange of the vent termination is 120 this would not be an acceptable installation Side ...

Page 18: ...egrity of internal supports For flex venting place the springs supplied with the pipe kit between the outer and inner pipes to keep the pipes separate and avoid any possible hot spots Montigo recommends the use of a flex section for the final pipe connected directly to the fireplace offering greater flexibility of installation and absorption of movement Firestops must be installed as required by N...

Page 19: ...DLT 12 5DLS1 12 5DLT2 20 5DSL2 20 5DAL 3 to 10 5DT AJ12 12 Rigid Telescopic Pipe 58DVA 17TA 58DVA 24TA 5DLA30 Elbows 5 8 Vent PEL 90MM m m 90º PEL 90FF f f 90º PEL 90FM f m 90º PEL 45FM f m 45º 58DVA E30 30 58DVA E45 45 58DVA E60 60 58DVA E90 90 5DE45 45 5DE90 90 5D45L 45 5D90L 90 5DT EL45 45 5DT EL90 90 Support Ring Plate PSPXT 8 58DVA DC 5CS 5DT CS Firestop FS 8 58DVA WFS 58DVA FS 5CS 5DFS 5DT F...

Page 20: ...er section from the outside of the structure To complete the installation fasten the Heat Shield Outer Section Termination frame to the structure Figure 15 e RHS101 Installation Figure 15 c RHS101 Installation Install by sliding Outer Section over vent pipe where it passes through the combustible construction Figure 15 a RHS8 Installation Install by sliding over vent pipe where it passes through t...

Page 21: ...epending on the model of the unit Use only low voltage wire and DO NOT connect any external power to the remote switch Ifanyoftheoriginalwiresuppliedwiththeapplianceisreplaced it must be replaced with the same type or its equivalent NOTE The switch location must not exceed 30 from the fireplace 1 5V AA type 1 5V AA type 1 5V AA type 1 5V AA type BLACK WHITE GREEN To PPO SPARK SENSOR RED BLACK BATT...

Page 22: ... remote operating instructions In order to start your pilot turning the main burner on with the switch remote or thermostat and then turning it off will reactivate the continuous pilot mode and reset the seven day timer A jumper is supplied with this unit that can be plugged into the wire harness connected to the controller This jumper cable gives the Remote Control the ability to operate the POD ...

Page 23: ...NY KIND TO TEST FOR LEAKS Pressure requirements Gas Pressure Natural Gas Propane Minimum inlet pressure 5 5in w c 11in w c Manifold pressure 3 5in w c 10in w c Section 5 Installing the gas line After gas line is connected each appliance connection valve and valve train MUST be checked while under normal operating pressure with either a Liquid Solution or Leak Detection Device to locate any source ...

Page 24: ...alled over the face of the unit as shown below Please be aware that the temperature of the fireplace face will be extremely hot and could be subject to cracking in seams of concrete board or tile installed directly on the face Please refer to the flush face finishing guide for more detailed instructions Figure 21 ddd Flush facing vs Standard vs High style High style Finishing Standard Finishing Fl...

Page 25: ... after the fireplace has been turned off Safety screens are mandatory while glass is hot and can reduce the risks of severe burns Please keep children away from the fireplace at all times CAUTION Notice Screen Bottom Tabs Screen Tab Receptacles Upper Screen Studs Upper Screen Stud Catch Left Side Detail Left Side Detail Removin The Safe To Remove t Simply gra outer corn with your finger and you On...

Page 26: ...oor on either side usually midway and lift upward lift the door carefully up and away from the front of the fireplace Place the door aside in a safe place while maintenance and or cleaning is being performed Removing the door The doors are removed in a few simple steps Follow these below to remove the horizontal access panel unlatch the door buckles and remove the door Replace in reverse order Rei...

Page 27: ...ion Place Logs C on top of Logs A Indentations on top of Logs A Installing the Ember Material The ember material is supplied in two packages Place the material evenly forward of both Log stands under logs A and B also forward from Logs C D Refer to figure 25b Ensure the burner holes are free of ember material after placing the embers Step 4 Completed Installation Figure 22 c Figure 22 c Figure 22 ...

Page 28: ...y pose potential safety hazards damage to the appliance and void manufacturer s warranty Linear Conv Installing the Firestones or optional Fireglass TheHL DF STfireplaceissuppliedwithfirestones RemovetheDoor s as shown on page 24 Follow these instructions to ensure all parts are removed or replaced as required Once the glass door s is removed place the firestones randomly across the pan as describ...

Page 29: ...F unless knob is pushed in slightly Do not force Standing Continuous Pilot Ignition SIT NOVA 820 with American Flame Electronic Ignition For Your Safety READ BEFORE LIGHTING C Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Force or attempt to repair may result in a fi...

Page 30: ... the Troubleshooting section Repeat step 5 9 If the system will not function correctly follow the instructions To Turn Off Gas To Appliance and call your service technician or gas supplier 1 STOP Read the safety information above on this label 2 Remove the lower Horizontal access panel 3 Turn ON manual ON OFF switch located below the horizontal access panel if available 4 Turn Incoming gas valve t...

Page 31: ...oflame 2 Control Module 4 Wiring Harness 5 Variable Speed fans If applicable 7 Proflame 2 remote control 8 Battery Pack 9 Manual override switch NOTE Can not be used with home automation systems SW1 Programing Button LED1 Red Diagnostic Light LED2 Amber Programing Remote Control Light Blue back lit LCD display On Off key Thermostat key Up Down arrow key Mode key Not Used Not Used CPI mode optional...

Page 32: ...ur 4 times to indicate transmitter s command is accepted The System is now initialized Temperature Indication Display With the system in the Off position press the Thermostat Key and the Mode Key at the same time Look at the LCD screen on the Remote Control to verify that a C or F is visible to the right of the Room Temperature display Turn On the Fireplace With the system Off turn the master over...

Page 33: ...o show that the room thermostat is On and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until the desired set temperature is displayed on the LCD screen of the Transmitter Smart Thermostat Remote Control Operation The Smart Thermostat function adjusts the flame height in accordance to the difference between the set point temperature and the actu...

Page 34: ...s to turn on off or adjust the fan speed A single beep will confirm reception of the command Disabling Thermostat Some jurisdictions and bedroom installations require the thermostat to be disabled 1 Partially take out one battery see Figure 27k 2 Insert the battery while holding down the thermostat button The remote screen will display Clr while the button is held down See Figure 27l 3 To enable t...

Page 35: ...uring the initial firing Silicone seals will off gas leaving a visual deposit of a white substance on combustion chamber walls This can easily be removed using normal household products Use a vacuum cleaner or whisk broom to keep the control compartment burner and firebox free from dust and lint Figure 28 Hi Lo Adjustment on the SIT Nova 820 gas valve Figure 28 b Hi Lo Adjustment on the SIT Profla...

Page 36: ...d Pressure are within acceptable limits Pilot lights but Main burner will not Light and igniter continues to spark 1 Check the Pilot Flame Sensor Rod and clean with steel wool or similar 2 Check the Pilot hood and clean with steel wool if dirty 3 Adjust pilot flame using the pilot adjustment screw if the pilot flame is too long or too short Flame should fully engulf the sensor rod and must be stab...

Page 37: ...2 Thermopile RPG001 RPG001 Piezo Ignitor PIEZO PIEZO Pilot Tubing RPTA03 RPTA03 Door RDTH38 RDTH42 Replacement Screen RSCH38 RSCH42 Replacement Parts List SIT IPI Proflame 2 Part H38DFST H42DFST Log Set RLGS47 RLGSH42ST NG Gas Valve hi low RGC3044 Propane Gas Valve hi low RGC3045 NG Gas Valve with stepper motor RGC3033 Propane Gas Valve with stepper motor RGC3034 NG Pilot Assembly RPA035 Propane P...

Page 38: ...ng fireplace penetration of an exterior building envelope Dimension A X 75 min overhang depth The overhang must extend at least 75 of the roof line height A Height is measured from bottom of fireplace opening to the ceiling Follow all product installation instructions including framing clearances to combustibles mantel heights Facing Requirements venting installation etc Use supplied safety screen...

Page 39: ...mbustion air inlet to other appliance for appliance 100 000 BTU H 30 KW 12 inches 12 inches M clearance to forced air supply inlet 6 feet 3 feet above air inlet N clearance above paved sidewalk or paved driveway located on public property 7 feet 7 feet P clearance under veranda porch deck or balcony 22 inches to combustibles 16 inches to non combustibles 22 inches to combustibles 16 inches to non ...

Page 40: ...um LP only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the appliance produce excessive temperatures will result in a fire hazard and void all warranties This warranty is transferable The appliance must remain in its original place of installation to be valid If the components of the appliance covered by this warranty are found to be defective...

Page 41: ...ritten consent of The Companies The Companies shall in no event be responsible for any warranty work done without first obtaining the Companies written consent The Companies employees and dealers have no authority to make any warranties to neither alter this warranty nor authorize any remedies in addition to or inconsistent with those stated within this warranty IF WARRANTY SERVICE IS NEEDED To ma...

Page 42: ...The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS Appendix C Amendment Gas Fireplace Equipment sold in the State of Massachusetts 5 08 Modifications to NFPA 54 Chapter 10 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon ...

Page 43: ...43 Notes xg0207 170223 ...

Page 44: ...xg0207 170223 Installation Maintenance Manual H38FSD H42FSD See Through Gas Fireplace ...

Reviews: