Summary of Contents for MA 0950

Page 1: ...Canada CAUTION READ ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLATION SAVE THIS OWNER S MANUAL FOR FUTURE REFERENCE Model No MA 0950 0 MA 0950 Evaporative Console Humidifier Owner s Manual SP6549 Manual 71235 7 12 05 3 17 PM Page 1 ...

Page 2: ...L SAFETY INSTRUCTIONS 2 Limited Warranty All products covered by this Owner s Manual are warranted against defects in work manship and materials for one year from the date of sale except for motors which are warranted for two years This warranty does not apply to damage from accident misuse or alteration nor where the connected voltage is more than 5 above the nameplate voltage nor to the equipmen...

Page 3: ...s Fill Light Yes Auto Humidistat Yes Auto Shut Off Yes Controls Rotary CUL Listed Yes Volts 120 A C Hertz 60 Amps 0 80 Watts 80 Know Your Humidifier 3 Based on an area with average insulation and an 8 foot ceiling height Bottle Handle Speed Control Bottle Base Filter Replacement No MAF 1 Fan Assembly Humidity Control Housing Assembly SP6549 Manual 71235 7 12 05 3 17 PM Page 3 ...

Page 4: ...sed in the form of vapor No water droplets will enter the home All evaporation into the air takes place in the humidifier which means that the residue left by evaporat ing water is not passed into the home but remains in the filter This natural process of evaporation helps eliminate the chance of white dust in the humidified output air CAUTION Use only liquid EPA Registered Bacteriostat available ...

Page 5: ...n affect the effi ciencies of the controls Unit should not be placed where warm air from a hot air register blows directly on unit Step 2 The humidifier should be positioned with the back cord exit side and left side at least 2 inches away from the wall Air needs to enter through all of the louvers in the housing assembly in order for the humidifier to operate at peak efficiency Locate nearest 120...

Page 6: ... whole house humidifier will hold 1 9 gallons of water The water bottle is designed with a Side Fill Cap Remove the Cap on the side of the water bottle by twisting counter clockwise Place the opening of the water bottle under a water faucet and fill If desired add liquid bacteriostat to help control the build up of bacteria and algae Do not use solid water treatments Solid debris could make the lo...

Page 7: ...turned off or unplugged Humidity Control Adjust the amount of humidity depending on your needs The humidifier will turn on and off as required to maintain level of humidity selected A medium setting half way between the controls rotation is recommended but there are times when low or high amount of humidity may be preferred For con stant operation of humidifier rotating the control all the way clo...

Page 8: ...rements for that setting or it is adjusting to the home con ditions The table below shows recom mended indoor humidity levels The figure below shows approximate relative humidi ty percentages which correspond to the various settings of the Humidity Control Using Your Humidifier Operating Tips for Best Performance 1 Position the humidifier next to an inside wall at least 2 inches from the wall and ...

Page 9: ...ilters we recommend moving the humidifier to an area where floor coverings are not susceptible to water damage i e kitchen or bath areas 2 Remove the water bottle and set aside Be sure not to bump or damage the lower spring valve 3 Grasp the housing assembly and lift straight up and away from the base and set aside The filter is now accessible 4 Take note of the filter position Remove the filter a...

Page 10: ...g assembly to the top of the base Return the water bot tle to the right of the housing assem bly and reposition the humidifier to its operating position 7 The humidifier is now ready to be filled for operation Replacement and Care of Filters continued 10 Base Position start and finish of coiled filter at center of base Align housing assembly bottom with top of base and reposition securely Return b...

Page 11: ...able at your local retail store Step 1 To make cleaning easier the humidifier base should be empty and completely dried out To accomplish this use the following method a Allow the humidifier to run until the amber Refill light illuminates and the automatic shutoff has stopped the humidifier fan b Unplug humidifier WARNING If humidifier is not un plugged fan could start after housing is removed Ste...

Page 12: ...to the base Coil the filter and position it between the uprights in the bottom of the base The start and finish of the coil should be captured in the centre of the base see diagram and the filter should be resting on the floor of the base 2 Return the housing assembly to the top of the base Return the water bottle to the right of the housing assembly and reposition the humidifier to its operating ...

Page 13: ... speed control clock wise Raise humidistat setting Turn humidity control counter clockwise until the fan turns off Allow up to 24 hours of run time for unit to adjust Designed to satisfy an area up to 2000 sq ft Free float from obstruction A small amount of water remains in the base after the Refill Light comes on Check Side Fill Cap and lower spring assembly Check for leak in water bottle Ensure ...

Page 14: ...Repair Parts Parts List for MoistAir Humidifier Model No MA 0950 0 14 SP6549 Manual 71235 7 12 05 3 17 PM Page 14 ...

Page 15: ...r is done by a qualified service technician 15 Key No Part No Description 1 830488 Housing Upper 2 830782 1 Assembly Control 3 830494 1 Knob 4 829821 Blade Fan 5 830778 Motor 6 823728 Switch Micro 7 830489 1 Housing Lower 8 MAF 1 Filter 9 829815 Screw Pan Hd Ty AB 6 x 1 2 SS 10 830496 1 Support Float 11 829816 Float 12 830484 1 Base 13 829808 Foot Rubber 14 830537 1 Bottle Includes Key 15 15 82469...

Page 16: ...11 04 FOR TECHNICAL HELP CALL 800 654 3545 FROM USA OR 888 744 4687 FROM CANADA Please have complete model number Emerson Tool Company For more information about MoistAir humidifiers visit our website at www moistair com SP6549 Manual 71235 7 12 05 3 17 PM Page 16 ...