background image

 

MOVING iMAGE TECHNOLOGIES 

INSTRUCTIONS 

FOR 

INSTALLATION, OPERATION, AND MAINTENANCE 

OF 

BP1 Automation 

 

Part numbers A000392 / A000393 

 
 

Manual Version 0.1 

 

 

MOVING iMAGE TECHNOLOGIES, LLC. 

17760 Newhope St. 

Fountain Valley, CA 

Telephone: (714) 751-7998 

Fax: (714) 429-7717  

www.movingimagetech.com

MiT

Summary of Contents for A000392

Page 1: ...R INSTALLATION OPERATION AND MAINTENANCE OF BP1 Automation Part numbers A000392 A000393 Manual Version 0 1 MOVING iMAGE TECHNOLOGIES LLC 17760 Newhope St Fountain Valley CA Telephone 714 751 7998 Fax...

Page 2: ...represent a commitment on the part of Moving Image Technologies hereinafter referred to as MIT MIT does not assume responsibility for errors that may appear in this document MIT or its subsidiaries de...

Page 3: ...he various pieces of equipment in the cinema auditorium such as dimmer and masking control The BP1 system is built on 19 wide 1 RU steel chassis The main circuit board incorporates detection logic tha...

Page 4: ...P P P P P P P P P A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A P P F F F F P P F F F F P P F F F F P P F F F F P P F F F F P P A A A A P P A A A A P P F F F F P P F F F F P...

Page 5: ...cabling may be required Or you may assign different functionality to the connectors than the default functions listed below if desired All connections between the BP1 and projector use 8 pin RJ 45 con...

Page 6: ...J3 7 NC J3 8 Common J4 PROJ GPO5 8 J4 1 Masking Flat J4 2 Common J4 3 Masking Scope J4 4 Common J4 5 XL Mover 2D J4 6 Common J4 7 XL Mover 3D J4 8 Common TB2 Fire Alarm legacy used in retrofit versio...

Page 7: ...tput a voltage to the projector of 9VDC current limited by a resistance of 700 ohms J1 1 Fire Alarm Mode Active J1 2 Fire Alarm Mode Active J1 3 Fire Alarm Cancel Reset J1 4 Fire Alarm Cancel Reset J1...

Page 8: ...ipping damage If damage is found notify the freight company immediately The contents of the carton contains the following items One A000393 BP1 complete system plus interconnect cables standalone One...

Page 9: ...s jumper setting only affects the behavior of the LED on the front panel Install the unit in an available rack space Connect the power supply to an AC receptacle Configure the projector as described i...

Page 10: ...R000226 BP1 Automation 10 v 0 1 03 21 Figure 5 1...

Page 11: ...r Breakout dp B085H8MQ35 ref sr_1_1_sspa The connections should be made as shown in Figure 5 2 DB37 Pin RJ45 Pin RJ45 Color 13 1 32 2 14 3 33 4 15 5 34 6 16 7 35 8 Figure 5 2 Some IMB manufacturers e...

Page 12: ...MP X s web UI Parts and Tools Needed A complete BP1 automation system or an IMC3 J automation retrofitted with the BP1 JNIOR replacement board as described in the Appendix Three cat 5e or cat 6 Ethern...

Page 13: ...igure 6 1 Configuring the ICMP X GPO Cues 3 Configure the GPIO cues that output from the ICMP X and input to the BP1 First create a new cue group for ease of access In this example it has been called...

Page 14: ...e cues click Add You will now create the five GPO cues that the BP1 can accept Dimmer Mid Dimmer Down Dimmer Up Screen Lights On Screen Lights Off Figure 6 3 Adding New Cues 5 Once you have added the...

Page 15: ...Up GPO 4 is not used by the BP1 5 Screen Lights On 6 Screen Lights Off GPO 7 and 8 are not used by the BP1 Figure 6 5 Configuring the ICMP X GPI Cues 6 Next create the two GPI cues that the ICMP X rec...

Page 16: ...of the fire alarm inputs to the BP1 If the fire alarm input to the BP1 mode is set to PULSE then the GPI to the ICMP X should be configured as On Input X Up If the fire alarm input is set to HOLD the...

Page 17: ...8 The next step is to configure what the ICMP X will actually do in response to receiving the GPI cue This is done by adding commands to the cue in the same way that GPO output commands were added to...

Page 18: ...eceived on GPI 1 fire alarm active will cause DCP playback to be paused and then half a second later the projector s dowser to close How you select and configure these commands will depend on how you...

Page 19: ...s preset macros that require their use The four projector GPO functions that the BP1 uses to trigger external devices are shown in Figure 6 13 GPO Output Function GPI 1 through 4 are not used by the B...

Page 20: ...he macro after adding the new command 13 Given that the XL Mover takes about 10 seconds to move the 3D filter into position and we don t want anything to be projected until this is complete we will no...

Page 21: ...r to save when done Using the cues in an ICMP X Show Playlist 14 We can now add the new automation cues that have been created to operate the BP1 into our show playlists SPLs In the ICMP X s web UI We...

Page 22: ...reated in the projector s Barco Communicator app are now available for use in SPLs To add a cue to your playlist drag it and drop it By clicking on the timecode you can also adjust the time delay afte...

Page 23: ...ting If the jumper is placed in the HOLD position the fire alarm input will be latched and will hold that state indefinitely until it s released with the button on the front panel If the jumper is pla...

Page 24: ...mation tray back into place and secure it 13 Plug in the power supply This completes the installation procedure Figure A 1 shows the IMC3 chassis after the installation of the BP1 Control PCB Fig A 1...

Page 25: ...MODELS AND PART NUMBERS A000392 001 BP1 Retrofit version Control PCB and cables only A000393 001 BP1 Standalone version complete REPLACEMENT PARTS LIST B000630 001 BP1 Control PCB only B000631 001 BP1...

Page 26: ...ported in writing to Moving Image Technologies not later than seven 7 days after the expiration of the twelve month warranty period c which are returned to Moving Image Technologies promptly after dis...

Page 27: ...of this document When contacting MiT be prepared to provide Model and serial number Part name and part number as shown in this manual Original Purchase order number The purchase order number is essen...

Reviews: