User's Manual

Entrust-LCD

Series UPS

Para Systems, Inc.

1455 LeMay Dr.

Carrollton, TX 75007

Phone: 1-972-446-7363

Fax: 1-972-446-9011

Internet: minutemanups.com

UPS Sizing:  sizemyups.com

PN - 34000493 R2x

Summary of Contents for ETR1000LCD

Page 1: ...User s Manual Entrust LCD Series UPS Para Systems Inc 1455 LeMay Dr Carrollton TX 75007 Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000493 R2x...

Page 2: ...rols and Indicators 6 3 Installation 9 4 Operation 12 5 Troubleshooting 15 6 Replacing the Battery 16 7 Obtaining Service 19 8 Specifications 20 9 Limited Product Warranty 22 A1 Declaration of Conform...

Page 3: ...the battery CAUTION To reduce the risk of electrical shock in conditions where the load equipment grounding cannot be verified disconnect the UPS from the AC wall outlet before installing a computer...

Page 4: ...to correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the computer with respect to the receiver Move the computer away from the receiver Plug th...

Page 5: ...UPS will sound a constant alarm to indicate that there is an Overload condi tion Battery Capacity Bar Graph Displays the amount of Battery Ca pacity available in the AC and Battery mode as 20 40 60 80...

Page 6: ...cement and all the cautions before installing the UPS Place the UPS in the final desired location and complete the rest of the installation procedure These UPSs are shipped with the internal batteries...

Page 7: ...the UPS Use only the interface cable that come with these UPSs The USB communications protocol is HID The HID USB driver comes standard in the Windows OS Simply connect the USB cable to the USB commun...

Page 8: ...release TEST BUTTON To perform a ten second user invoked battery test With the UPS in theAC normal mode press and hold the On Off Test Button until the alarm sounds four beeps and then release During...

Page 9: ...yed on the LCD screen the alarm will sound continu ously and the output will be turned off The fault condition in some instances may be cleared by turning the UPS off and then on If the fault conditio...

Page 10: ...re attempting to ser vice the batteries Typical battery life is 3 to 5 years Environmental factors do affect battery life High temperatures poor utility power and frequent short duration discharges ha...

Page 11: ...f the model information about your unit d The serial number of your unit e Any information on the failure including LEDs that may be illuminated or error codes displayed f A description of the protect...

Page 12: ...hutdown Immediately Chapter 8 Specifications BATTERY SYSTEM Typical Recharge Time Typical Battery Life 3 to 5 years Environmental factors do affect battery life High temperatures poor utility power an...

Page 13: ...RANTIES EX PRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITYAND FIT NESS FORAPARTICULAR PURPOSE Some states do not permit limitation of implied warranties therefore the aforesaid limitation s...

Page 14: ...25 24 Notes Notes...