background image

 
 
 

 

 

MS400870M 

 

 
 

 
 

24 Port GBE SFP Switch 19

 1U 

24X10/100/1000T Combo 100/1000X SFP

 

 
 

 
 

  

 

Network Management 

 

 
 
 

User’s Guide 

 

Version 0.96 

 
 
 

Summary of Contents for MS400870M Series

Page 1: ...1 MS400870M 24 Port GBE SFP Switch 19 1U 24X10 100 1000T Combo 100 1000X SFP Network Management User s Guide Version 0 96 ...

Page 2: ...erence to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into a different outlet from that the receiver is connected Consult your loca...

Page 3: ...on Date 0 95 Add CLI and Web interface 1 07 00 2009 06 0 96 Modify quick keys 1 07 00 2009 06 Note This User s Manual is written or revised according to the officially released Firmware version The content of this Manual is subject to change without prior notice ...

Page 4: ...27 2 5 3 Console command mode 28 2 5 4 IP command mode 28 2 5 5 Service command mode 29 2 5 6 Syslog command mode 32 2 5 7 System command mode 32 2 5 8 Time server command mode 32 2 5 9 Upgrade command mode 32 2 5 10 User command mode 33 2 6 Config mode 34 2 6 1 Aggr command mode 35 2 6 2 CFM command mode 36 2 6 3 Dot1x command mode 38 2 6 4 IGMP filter command mode 39 2 6 5 IGMP command mode 40 2...

Page 5: ...onfiguration 83 4 4 5 1 Configure System 83 4 4 5 2 Configure Port Admin State 84 4 4 5 3 Configure Port Reauthenticate 85 4 4 6 MAC Address Management 86 4 4 6 1 MAC Table Learning 87 4 4 6 2 Static MAC Table Configuration 87 4 4 7 VLAN Configuration 89 4 4 7 1 Port Based VLAN 89 4 4 7 2 802 1Q VLAN Concept 91 4 4 7 3 802 1Q VLAN 94 4 4 7 3 1 Configure VLAN 95 4 4 7 3 2 Configure VLAN Aware 96 4 ...

Page 6: ... 143 4 5 1 Switch Port State 144 4 5 2 Port Traffic Statistics 145 4 5 3 Port Packet Error 146 4 5 4 Port Packet Analysis Statistics 147 4 5 5 LACP Monitor 148 4 5 5 1 LACP Port Status 148 4 5 5 2 LACP Statistics 149 4 5 6 RSTP Monitor 150 4 5 6 1 RSTP VLAN Bridge Overview 150 4 5 6 2 RSTP Port Status 151 4 5 6 3 RSTP Statistics 151 4 5 7 802 1X Monitor 152 4 5 7 1 80 2 1X Port Status 152 4 5 7 2 ...

Page 7: ...7 4 6 2 Update 166 4 6 3 Load Factory Settings 167 4 6 4 Load Factory Settings Except Network Configuration 168 4 6 5 Backup Configuration 168 4 7 Save Configuration 169 4 8 Reset System 170 ...

Page 8: ...ual speed combo ports plus 2 Giga combo port managed Switch fixed 1 AC MS400870M 2A 24 dual speed combo ports plus 2 Giga combo port managed Switch fixed 2 Redundant AC MS400870M 1D 24 dual speed combo ports plus 2 Giga combo port managed Switch fixed 1 DC MS400870M 2D 24 dual speed combo ports plus 2 Giga combo port managed Switch fixed 2 Redundant DC These 4 models have the same front panel Figu...

Page 9: ... use Telnet to login and monitor its status remotely SNMP Management SNMP is also done over the network Apart from standard MIB Management Information Bases an additional private MIB is also provided for SNMP based network management system to compile and control Web Management Web Management is done over the network and can be accessed via a standard web browser such as Microsoft Internet Explore...

Page 10: ...d network management system is used to manage the Managed Switch through the network remotely When you use a SNMP based network management system the Managed switch becomes one of the managed devices network elements in that system The Managed switch management module contains an SNMP agent that will respond to the requests from the SNMP based network management system These requests which you can...

Page 11: ... for optical fiber communications to also communicate over unshielded twisted pair networking cable SFP slot for 3 3V mini GBIC module supports hot swappable SFP fiber transceiver Before connect the other switches workstation or Media Converter make sure both side of the SFP transfer are with the same media type for example 1000Base SX to 1000Base SX 1000Bas LX to 1000Base LX And check the fiber o...

Page 12: ...ou consult with the allocation organization where your IP addresses were obtained Remember that none of the two devices on a network can have the same address If you connect to the outside network you must change all the arbitrary IP addresses to comply with those you have been allocated by the allocation organization If you do not do this your outside communications will not be performed A subnet...

Page 13: ... switch cannot be reached by any other means You also need the Local Console Management to setup the Switch network configuration for the first time You can setup the IP address and change the default configuration to desired settings to enable Telnet or SNMP services Follow these steps to begin a management session using Local Console Management Step 1 Attach the serial cable the RS 232 DB 9 port...

Page 14: ...ign the IP address for the first time Follow these steps to manage the Managed Switch through Telnet session Step 1 Use Local Console to assign an IP address of the Managed Switch IP address Subnet Mask Default gateway IP address if required Step 2 Run Telnet Step 3 Log into the Switch CLI mode Limitations When using Telnet keep the following in mind Only two active Telnet sessions can access the ...

Page 15: ...nd enter the required command and password and when you want to enter Config mode you must enter the required command in Enable mode The following table provides an overview of this Managed Switch Command Mode Access Method Switch Prompt Displayed Exit Method User mode Log in Console logout Enable mode From user mode enter the enable command Console exit Config mode From the enable mode enter the ...

Page 16: ...le mode backup While in Enable mode enter the backup command Console backup Backup configuration file via FTP or TFTP cfm While in Enable mode enter the cfm command Console cfm Run loopback linktrace and delay measurement test configure While in Enable mode enter the configure command Console config Enter Config mode Console While in Enable mode enter the Console command Console Console Set up tim...

Page 17: ...able mode enter the syslog command Console syslog Configure the Switch syslog parameters system While in Enable mode enter the system command Console system Configure the Managed Switch s basic information time server While in Enable mode enter the time server command Console time server Synchronize the time of a computer client or server to another server upgrade While in Enable mode enter the up...

Page 18: ... command Console Exit from current mode help When in Config mode enter the help command Console config Show available commands that can be used in Config mode history When in Config mode enter the history command Console config List commands that have been used igmpfilter When in Config mode enter the igmpfilter command Console config igmpfilter Configure IGMP filtering settings igmp When in Confi...

Page 19: ...etc vlan When in Config mode enter the vlan command Console config vlan Set up VLAN mode and VLAN configuration show When in Config mode enter the show command or enter the show command and followed by the command you would like to view its current setting Console config Show a list of commands or show the current setting of each listed command 2 3 2 General commands and quick keys 2 3 2 1 Quick k...

Page 20: ...all commands that are available in the current mode 3 Purpose Description This column lists each command s purpose and description in the current mode 4 Usage This column lists each command s usage in the current mode 2 3 2 3 Show command In each mode users can enter show command to view a list of commands view each command s current setting and view system information The following explains how s...

Page 21: ...odel name Firmware Version This shows the firmware version of this Managed Switch M B Version This shows the motherboard version of this Managed Switch Serial Number This shows the serial number of this Managed Switch Date Code This shows the date code of this Managed Switch Up Time This shows how long this Managed Switch has been turned on since the last reboot Local Time This shows the local tim...

Page 22: ...nsole then the current setting of qos command will be displayed Within QoS the rate limit configurations can be set You can type show qos rate limit in any mode to view its current setting Show Currently Configured Settings When you type a specific command in Enable or Config mode to configure or edit the setting of a certain function you can type show to verify the setting you have just configure...

Page 23: ...n 2 3 2 4 Usage Help When entering a command without the required parameter the system will remind users of the command s syntax and parameter 2 3 2 5 Press Any Key to Continue When a command generates more than one page outputs the prompt Press Ctrl C to exit or any key to continue will be displayed at the bottom of the screen Simply press any key to view next page information or press Ctrl C to ...

Page 24: ...in the angle bracket administrator read_and_write read_only access_denied Several options separated by a vertical bar are available for selection Select one option within the angle bracket etype etype 0x600 FFFF vid vid 1 4094 port udp_tcp_port 0 65535 dscp dscp 0 63 tos tos_list 0 7 tag_prio tag_prio_list 0 7 This is an optional parameter or value and six parameters are available for selection 2 ...

Page 25: ...Description cfm Run OAM 802 1ag CFM loopback linktrace delay measurement test enable Enter the Enable mode exit Leave the User mode help Display a list of available commands in User mode history Display the command history logout Logout from the Managed Switch ping Allow users to ping a specified network device show Show a list of commands or show the current setting of each listed command ...

Page 26: ...tch restore Restore configuration via FTP or TFTP service Three different management services are provided to configure the Managed Switch these are Telnet SNMP and Web syslog Configure the Managed Switch s syslog settings system Configure system information time server Synchronize the time of a computer client or server to another server upgrade Allow users to update firmware and restore configur...

Page 27: ...eply LBR The LBM LBR mechanism is similar to ICMP ping function in the IP network However since the interfaces of an ND in an Ethernet network may not possess their individual IP address the operator can not achieve fault verification by ICMP ping in such a network environment Fault isolation In addition to the LBM LBR mechanism IEEE 802 1ag supports fault isolation through Linktrace Messages LTM ...

Page 28: ...onnect the Managed Switch when the user is inactive secs 0 or 5 9999 seconds For example Console Console time out 300 2 5 4 IP command mode Prompt Command Parameter Description Console ip type manual dhcp If DHCP is selected and a DHCP server is also available on the network the Managed Switch will automatically get the IP address from the DHCP server If Manual mode is selected the user needs to s...

Page 29: ...number that allows telnet access The default port number is set to 23 in telnet mode However you can also identify a port number between 1025 and 65535 For example Console service telnet port 23 Console service snmp mode enable disable In service command mode it provides three modes for users to choose from these are telnet snmp and web If you type snmp you can set up either to enable or disable t...

Page 30: ...y browses the Managed Switch without proper access right the Managed Switch will respond nothing For example if a community only has Read Write privilege then it cannot browse the Managed Switch s user table NOTE 2 If you would like to edit the settings of your new account you can enter the command community community name under the Console service snmp For example If you want to edit settings of ...

Page 31: ... the Managed Switch to send a trap when the Managed Switch warm starts auth fail enable disable To enable or disable the Managed Switch to send authentication failure trap when any unauthorized users attempt to login port link enable disable To enable or disable the Managed Switch to send port Link Up Down trap storm enable disable To enable or disable broadcast storm trap sending from the Managed...

Page 32: ...ocation Enter a brief description of the Managed Switch location up to 55 alphanumeric characters As the name implies the location is for reference only for example 13th Floor 2 5 8 Time server command mode Prompt Command Parameter Description Console time server mode enable disable To enable or disable time server ip addr ip_addr test Enter the NTP time server IP address 2nd addr 2nd_addr test En...

Page 33: ...to upgrade Firmware you do not need to specify password filelocation Enter the file location within the FTP or TFTP server 2 5 10 User command mode Command Parameter Description Console user add username password administrator read_and_write read_only access_denied Add a new user and specify its access privilege administrator read_and_write read_only access_denied Four operation privileges are ava...

Page 34: ...second RADIUS server 2 6 Config mode In order to manage the Managed Switch and set up advanced switching functions enter the configure command from Console directory and then type in Then the screen shows as follows Command Description aggr Configure LACP functions cfm Configure the Managed Switch OAM 802 1ag CFM settings dot1x Configure the Managed Switch to send information when 802 1x client au...

Page 35: ...ure labor costs if networking needs changes Link aggregation can allow the use of these extra cables to increase backbone speeds with little or no extra cost if ports are available This Managed switch supports 2 link aggregation modes static Port Trunk and dynamic Link Aggregation Control Protocol LACP using the IEEE 802 3ad standard These allow several devices to communicate simultaneously at the...

Page 36: ...LACP LACP ports that are designated as passive cannot initially send LACP control frames In order to allow the linked port group to negotiate adjustments and make changes dynamically one end of the connection must have active LACP ports For example Console config aggr lacp role 1 4 10 15 18 19 active 2 6 2 CFM command mode Prompt Command Parameter Description Console config cfm dom add domain_name...

Page 37: ...f you would like to edit the settings of your new domain you can enter the command domain domain name under the Console config cfm For example If you want to edit settings of the account mydomain you can use the following commands to enter the editing mode Console config cfm domain mydomain Console snmp community_mydomain Console config cfm assoc add assoc_name vlan_id ccm_interval mhf This allows...

Page 38: ...mand mode Prompt Command Parameter Description Console config dot1x sys mode enable disable To enable or disable 802 1X for the Managed Switch server ip_addr RADIUS Authentication server address secret shared_secret The identification word or number assigned to each RADIUS authentication server with which the client shares a secret shared_secret up to 30 characters reauth enable disable To enable ...

Page 39: ... Console config segment add 2 myseg 224 0 1 5 235 255 255 253 delete seg_id To delete a registered segment Console config profile add profile_name seg_id seg_id To create a profile profile_name up to 20 characters seg_id 1 400 The field for segment ID is from the entry registered in Segment option For Example Console config profile add myprofile 2 delete profile_name To delete a registered profile...

Page 40: ...uter ports only when disabled vlanstate vid enable disable When enabled the port in VLAN will monitor network traffic and determine which hosts want to receive the multicast traffic vid 1 4094 For example Console config igmp vlanstate 1 enable vlanquerier vid enable disable When enabled the port in VLAN can serve as the Querier which is responsible for asking hosts whether they want to receive mul...

Page 41: ...ble Specify the preferred target port for mirroring target_port 1 26 or 0 disabled For example Console config mirror target port 24 2 6 8 MVR command mode MVR refers to Multicast VLAN Registration that enables a media server to transmit multicast stream in a single multicast VLAN when clients receiving multicast VLAN stream can reside in different VLANs Clients in different VLANs intend to join or...

Page 42: ...l setting add vlan_id rec_port_list sor_port_list To add a MVR VLAN ID and specify its Receive and Source Port vlan_id 1 4094 rec_port_list 1 26 sor_port_list 1 26 For example Console config mvr add 4094 1 4 10 15 18 19 5 9 16 17 delete vlan_id To delete a registered MVR VLAN ID vlan_id 1 4094 For example Console config mvr delete 4094 Console config mvr group add vlan_id ip ip To add a new MVR gr...

Page 43: ... Network traffic is always unpredictable and the only basic assurance that can be offered is the best effort traffic delivery To overcome this challenge Quality of Service QoS is applied throughout the network This ensures that network traffic is prioritized according to specified criteria and receives preferential treatments QoS enables you to assign various grades of network service to different...

Page 44: ..._list high medium normal low To configure default class of each port port_list 1 26 high medium normal low Specify one priority level to classify data packets For example Console config qos class 1 5 10 high tagpriority port_list tag_priority To configure tag priority port_list 1 26 tag_priority 0 7 For example Console config qos tagpriority 1 5 10 7 mode port_list strict weighted To specify stric...

Page 45: ...selected ports port_list 1 26 bit_rate 500 1000000 KBits Sec 0 is disabled For example Console config qos rate limit egress 3 6 15 20 2500 Console config qos storm unicast packet_rate To set up unicast packet rate packet_rate disable 1 2 4 8 16 32 64 128 256 512 1k 2k 4k 8k 16k 32k 64k 128k 256k 512k 1024k For example Console config qos storm unicast disable multicast packet_rate To set up multica...

Page 46: ... 14 57344 15 61440 For example Console config rstp sys sys prio 1 max age max_age Max Age setting of the Managed Switch in a specific VLAN max_age 6 200 Seconds For example Console config rstp sys max age 20 hello time hello_time Hello Time setting of the Managed Switch in a specific VLAN hello_time 1 10 Seconds For example Console config rstp sys hello time 2 delay forward_delay The Managed Switc...

Page 47: ..._false will be forced to turn off Auto will detect the status automatically For example Console config rstp p2p 1 4 10 15 18 19 forced_true Console config rstp aggr state enable disable To enable or disable RSTP state of aggregated ports path cost path_cost To specify aggregated ports path cost path_cost 0 200000000 For example Console config rstp aggr path cost 100000 priority priority To specify...

Page 48: ...authorized IP address Each port s Port Number 1 22 configuration for DHCP Static IP or Unlimited Prompt Command Parameter Description Console config ska opt82 mode enable disable To enable or disable DHCP Opt 82 Relay Agent Global setting port port_list port_list 1 24 For example Console config ska opt82 port 1 4 10 15 18 19 trust port port_list When Trust Port is set to enabled a it will receive ...

Page 49: ...olation enable disable If port isolation is set to enable the customer port port 1 24 can t communicate to each other ipv6 filter enable disable To enable or disable ipv6 filter upnp filter enable disable To enable or disable upnp filter Console config ska static ip add ip mask vlan_ip port Add a static IP vlan_ip 1 4094 port 1 24 delete ip mask vlan_ip port Delete a static IP vlan_ip 1 4094 port ...

Page 50: ... A Virtual Local Area Network VLAN is a network topology configured according to a logical scheme rather than the physical layout VLAN can be used to combine any collections of LAN segments into a group that appears as a single LAN VLAN also logically segments the network into different broadcast domains All broadcast multicast and unknown packets entering the Switch on a particular VLAN will only...

Page 51: ... delete vid To delete a registered VLAN For example Console config vlan dot1q delete 1 Console config vlan aware port_list enable disable To enable or disable VLAN aware port_list 1 26 For example Console config vlan aware 1 4 10 15 18 19 enable filter port_list enable disable To enable or disable ingress filter port_list 1 26 For example Console config vlan filter 1 4 10 15 18 19 enable frame typ...

Page 52: ...ng is 1 port_list 1 26 pvid 1 4094 For example Console config vlan pvid 1 4 10 15 18 19 1 egress port_list normal untag To specify normal or untag to each port port_list 1 26 normal untag The default setting to all ports is Normal For example Console config vlan egress 1 4 10 15 18 19 untag ...

Page 53: ...mory resources required for the complete network management SNMP Manager often composed by desktop computer work station and software program such like HP OpenView Totally 4 types of operations are used between SNMP Agent Manager to change the MIB information These 4 operations all use the UDP IP protocol to exchange packets GET This command is used by an SNMP Manager to monitor managed devices Th...

Page 54: ...e RS 232 DB 9 Console port or any of the 10 100 1000Base TX RJ 45 ports as the temporary RJ 45 Management Console port to set up the assigned IP parameters of the Managed Switch IP address Subnet Mask Default Converter Switch IP address if required Run a Web browser and specify the Managed Switch s IP address to reach it The Managed Switch s default IP can be reached at http 192 168 0 1 before any...

Page 55: ... view the IP address and related information of the Managed Switch required for network management applications 4 Switch Management Set up switch port configuration VLAN configuration and other functions 5 Switch Monitor View the operation status and traffic statistics of the ports 6 System Utility Ping Firmware Upgrade Load Factory Settings etc 7 Save Configuration Save all changes to the system ...

Page 56: ...aged Switch in relation to your network for example Backbone 1 This name is mainly used for reference only System Location Enter a brief description of the Managed Switch location up to 55 alphanumeric characters Like the name the location is for reference only for example 13th Floor Model Name View only field that shows the product s model name Firmware Version View only field that shows the prod...

Page 57: ...y un authorized operations only registered users are allowed to operate the Managed Switch Any users who want to operate the Managed Switch need to register into the user list first To view or change current registered users select User Authentication from the main menu and then the following screen page shows up Up to 10 Users can be registered Click New to add a new user and then the following s...

Page 58: ...scription Enter a unique description for the user up to 35 alphanumeric characters This is mainly for reference only IP Security Enable or disable the IP security function If enabled the user can access the Managed Switch only through the management station which has exact IP address specified in IP address field below If disabled the user can access the Managed Switch through any stations IP Addr...

Page 59: ...ng screen page appears When RADIUS Authentication is enabled User login will be according to those settings on the RADIUS server s Note For advanced RADIUS Server set up please refer to Appendix A or the free RADIUS readme txt file on the disc provided with this product Secret Key The word to encrypt data of being sent to RADIUS server RADIUS Port The RADIUS service port on RADIUS server Retry Tim...

Page 60: ...fic Telnet and Console services 4 Time Server Configuration Set up the time server s configuration 5 Device Community View the registered SNMP community name list Add a new community name or remove an existing community name 6 Trap Destination View the registered SNMP trap destination list Add a new trap destination or remove an existing trap destination 7 Trap Configuration View the Managed Switc...

Page 61: ...work The default factory setting is 192 168 0 1 Subnet Mask Specify the subnet mask The default subnet mask values for the three Internet address classes are as follows Class A 255 0 0 0 Class B 255 255 0 0 Class C 255 255 255 0 Gateway Specify the IP address of a gateway or a router which is responsible for the delivery of the IP packets sent by the Managed Switch This address is required when th...

Page 62: ...Management service 4 3 3 RS232 Telnet Console Configuration Click the option RS232 Telnet Console Configuration from the Network Management menu and then the following screen page appears Baud Rate 9600 bps RS 232 setting view only field Stop Bits 1 RS 232 setting view only field Parity Check None RS 232 setting view only field Word Length 8 RS 232 setting view only field ...

Page 63: ...ddress NTP time server address 2nd Time Server Address When the default time server is down the Managed Switch will automatically connect to the 2nd time server Synchronization Interval The time interval to synchronize from NTP time server Time Zone Select the appropriate time zone from the pull down menu Daylight Saving Time To enable or disable the daylight saving time function It is a way of ge...

Page 64: ... then the following screen page appears Click Edit to view the current community settings Click Delete to remove a registered community Current Total Max Agents View only field Current This shows the number of current registered communities Total This shows the number of total registered community users Max Agents This shows the number of maximum number available for registration The default maxim...

Page 65: ...ed in IP address field below If disabled Community can access the Managed Switch through any management stations IP Address Specify the IP address used for IP Security function SNMP Level Click the pull down menu to select the desired privilege for the SNMP operation NOTE When the community browses the Managed Switch without proper access right the Managed Switch will respond nothing For example i...

Page 66: ...witch to send a trap when the Managed Switch warm starts Authentication Failure Trap Enable or disable the Managed Switch to send authentication failure trap after any unauthorized users attempt to login Port Link Up Down Trap Enable or disable the Managed Switch to send port link up link down trap Broadcast Storm Trap Enable or disable broadcast storm trap sending from the Managed Switch when bro...

Page 67: ...tion message to Log server Log Server Click the Pull down menu to enable or disable Mal attempt log SNTP Status View only field that shows the SNMP status Log Server IP 1 Specify the default Log server IP address Log Server IP 2 Specify the second Log server IP address Log Server IP 3 Specify the third Log server IP address When the default Log Server is down the Managed Switch will automatically ...

Page 68: ...AC address enable or disable MAC security etc 7 VLAN Configuration Set up VLAN mode and VLAN configuration 8 QoS Configuration Set up the priority queuing rate limit and storm control 9 Port Mirroring Set up target port to mirror source port so as to enable traffic monitoring 10 IGMP Snooping Enable or disable IGMP and set up IGMP VLAN ID configuration 11 Static Multicast Configuration To create e...

Page 69: ...ears Maximum Frame Size Specify the maximum frame size between 1518 and 9600 bytes The default maximum frame size is 9600bytes MAC Address Aging Time Specify MAC Address aging time between 0 and 1048575 seconds SFP Safety Temperature Enter the specific temperature for the Managed Switch to detect the SFP DMI safety range Default 0 70C SFP Safety Voltage Enter the specific Voltage for the Managed S...

Page 70: ...onfiguration from the Switch Management menu and then the following screen page appears Port Number Click the pull down menu to select the port number for configuration Port State Enable or disable the current port state Preferred Media Type Select copper or fiber as the preferred media type Port Type Select Auto Negotiation or Manual mode as the port type Port Speed When you select Manual port ty...

Page 71: ...eds changes Link aggregation can allow the use of these extra cables to increase backbone speeds with little or no extra cost if ports are available This Managed switch supports 2 link aggregation modes static Port Trunk and dynamic Link Aggregation Control Protocol LACP using the IEEE 802 3ad standard These allow several devices to communicate simultaneously at their full single port speed while ...

Page 72: ...ink Aggregation menu the following screen page appears There are two fields for you to set up packets according to operations Source MAC Address Enable or disable packets according to source MAC address Destination MAC Address Enable or disable packets according to destination MAC address ...

Page 73: ...age appears The Managed Switch allows users to create 13 trunking groups Each group consists of 2 to 16 links ports Click New to add a new trunking group and then the following screen page appears Click Delete to remove a current registered trunking group setting Click Edit to view and edit a registered trunking group s settings ...

Page 74: ...naged Switch supports dynamic Link Aggregation Control Protocol LACP which is specified in IEEE 802 3ad Static trunks have to be manually configured at both ends of the link In other words LACP configured ports can automatically negotiate a trunked link with LACP configured ports on another devices You can configure any number of ports on the Managed Switch as LACP as long as they are not already ...

Page 75: ... menu of Select Setting Ports in an aggregated link group must have the same LACP port Key In order to allow a port to join an aggregated group the port Key must be set to the same value The range of key value is between 0 and 255 When key value is set to 0 the port Key is automatically set by the Managed Switch Configure Port Role ...

Page 76: ...e Spanning Tree Protocol STP defined in the IEEE Standard 802 1D creates a spanning tree within a mesh network of connected layer 2 bridges typically Ethernet switches and disables the links which are not part of that tree leaving a single active path between any two network nodes Multiple active paths between network nodes cause a bridge loop Bridge loops create several problems First the MAC add...

Page 77: ...an make a rapid transition This is one of the major elements which allows RSTP to achieve faster convergence times than STP Click the folder Rapid Spanning Tree from the Switch Management menu and then three options within this folder will be displayed as follows RSTP Switch Settings Set up system priority max Age hello time etc RSTP Aggregated Port Settings Set up aggregation path cost priority e...

Page 78: ...g tree does not send out a hello packet for a long period of time it is assumed to be disconnected This timeout is set with Hello Time Periodically a hello packet is sent out by the Root Bridge and the Designated Bridges that are used to communicate information about the topology throughout the entire Bridged Local Area Network Forward Delay It is the time spent in each Listening and Learning stat...

Page 79: ...to ensure maximum performance This will tell the switch to immediately start forwarding traffic on the port and not bother trying to establish a RSTP connection Otherwise turn it off Point to Point Forced True parameter indicates a point to point P2P shared link P2P ports are similar to edge ports however they are restricted in that a P2P port must operate in full duplex Similar to edge ports P2P ...

Page 80: ...id Spanning Tree menu and then the following screen page appears Configure Port State Select State from the pull down menu of Select Setting This allows ports to be enabled or disabled When it is On RSTP is enabled Configure Port Path Cost Select Path Cost from the pull down menu of Select Setting ...

Page 81: ...ault value is 0 Configure Port Priority Select Priority from the pull down menu of Select Setting You can choose Port Priority value between 0 and 240 The default value is 0 Configure Port Edge Select Edge from the pull down menu of Select Setting ...

Page 82: ...t to enabled or disabled When it is On Port Edge is enabled Configure Port Point2point Select Point2point from the pull down menu of Select Setting Set up the Point to Point setting The default setting is Forced True ...

Page 83: ... full authorization or local authentication on the Switch Click the folder 802 1X Configuration from the Switch Management menu and then three options will be displayed as follows Configure System Set up 802 1X RADIUS IP RADIUS Secret Reauthentication Timeout Configure Port Admin State Set up aggregation Path Cost Priority Edge etc Configure Port Reauthenticate Set up Physical ability and edge sta...

Page 84: ...enable or disable Reauthentication Reauthentication Period A constant time that defines a nonzero number of seconds between periodic reauthentication of the client EAP Timeout Enter the time in seconds that the Managed Switch will wait for responses from the server host to an authentication request 4 4 5 2 Configure Port Admin State Click the option Configure Port Admin State from the 802 1X Confi...

Page 85: ... deny access to all clients either dot1x aware or otherwise Auto This requires a dot1x aware client to be authorized by the authentication server Accesses from clients that are not dot1x aware will be denied 4 4 5 3 Configure Port Reauthenticate Click the option Configure Port Reauthenticate from the 802 1X Configuration menu and then the following screen page appears ...

Page 86: ...ss Management Click the folder MAC Address Management from the Switch Management menu and then the following screen page appears MAC Table Learning To enable or disable learning MAC address function Static MAC Table Configuration To create edit or delete Static MAC Table setting ...

Page 87: ...u and then the following screen page appears Auto To enable the port learning MAC address Disabled To disable port learning MAC address 4 4 6 2 Static MAC Table Configuration Click the option Static MAC Table Configuration from the MAC Address Table menu and then the following screen page appears ...

Page 88: ...ch can support up to 128 entries of MAC security list Click New to add a new MAC address entity and then the following screen page appears Click Edit to view and edit the selected MAC address entity Click Delete to remove a MAC address entity Current Total Max The number of current total and maximum MAC address entry or entries ...

Page 89: ...d of physical locations End nodes that frequently communicate with each other are assigned to the same VLAN no matter where they are physically located on the network Another benefit of VLAN is that you can change the network topology without physically moving stations or changing cable connections Stations can be moved to another VLAN and thus communicate with its members and share its resources ...

Page 90: ...roadcast multicast packets in every VLAN the traffic between two ports will be two way without restrictions Click New to add a new VLAN entity and then the following screen page appears Use Edit to view and edit the current VLAN setting Click Delete to remove a VLAN entity VLAN Name Use the default name or specify a VLAN name ...

Page 91: ...dth as well as provide a higher level security between segments of internal networks The 802 1Q frame format is shown below PRE Preamble 62 bits Used to synchronize traffic SFD Start Frame Delimiter 2 bits Marks the beginning of the header DA Destination Address 6 bytes The MAC address of the destination SA Source Address 6 bytes The MAC address of the source TCI Tag Control Info 2 bytes set to 81...

Page 92: ... The differences between Ingress and Egress configurations can provide network segmentation Moreover they allow resources to be shared across more than one VLAN Important VLAN Definitions Ingress The point at which a frame is received on a switch and the switching decisions must be made The switch examines the VID if present in the received frames header and decides whether or not and where to for...

Page 93: ... compliant switch can be configured as tagging or un tagging Ports with taggings Enable will put the VID number priority and other VLAN information into the header of all packets that flow into and out of it If a packet has been tagged previously the port will not alter the packet and keep the VLAN information intact The VLAN information in the tag can then be used by other 802 1Q compliant device...

Page 94: ... the port on which they were received Forwarding decisions are based upon this PVID in so far as VLANs are concerned Tagged packets are forwarded according to the VID contained within the tag A PVID is assigned to the tagged packet but the PVID is not used to make packet forwarding decisions the VID is VLAN aware switches must keep a table so as to relate PVIDs within the Switch to VIDs on the net...

Page 95: ...ng To set up VLAN Aware Ingress Filter Frame Type Port VLAN ID Port Egress Mode 4 4 7 3 1 Configure VLAN Click New to add a new VLAN entity an then the following screen page appears Click Edit to view and edit current IEEE 802 1Q Tag VLAN setting Click Delete to remove a VLAN entity ...

Page 96: ... VLAN name VLAN Members If you select V from the pull down menu in each port it denotes that the ports selected belong to VLAN 4 4 7 3 2 Configure VLAN Aware The following screen page appears if you choose Tag VLAN Settings and then select VLAN Aware from the pull down menu of Select Setting ...

Page 97: ... when you choose Tag VLAN Settings and then select Ingress Filter from the pull down menu of Select Setting Click the pull down menu to select Enable or Disable The default setting is enabled to all ports 4 4 7 3 4 Configure Frame Type The following screen page appears if you choose Tag VLAN Settings and then select Frame Type from the pull down menu of Select Setting ...

Page 98: ...set to All they will send and receive both VLAN tagged and untagged packets 4 4 7 3 5 Configure Port VLAN ID The following screen page appears if you choose Tag VLAN Settings and then select Port VLAN ID from the pull down menu of Select Setting Port VLAN ID PVID The range of PVID is between 1 and 4094 VLAN ID will be assigned to untagged frames received on the interface The default setting is 1 ...

Page 99: ... offered is the best effort traffic delivery To overcome this challenge Quality of Service QoS is applied throughout the network This ensures that network traffic is prioritized according to specified criteria and receives preferential treatments QoS enables you to assign various grades of network service to different types of traffic such as multi media video protocol specific time critical and f...

Page 100: ... To create edit or delete QCL settings QoS Rate Limiters To configure each port s Policer and Shaper Rate Storm Control To enable or disable Storm Control 4 4 8 1 QoS Port Configuration Select the option QoS Port configuration from the QoS Configuration menu and then the following screen page appears Configure Default Class ...

Page 101: ...ass level Low Normal Medium or High The default class level of each port is Low Configure QCL A QCL number is assigned to each port based on the information in the QCL table Please refer to QoS Control List for QCL settings Configure User Priority ...

Page 102: ...tions from the pull down menu for CoS Class of Service priority tag values The default value is 0 The default 802 1p settings are shown in the following table Priority Level normal low low normal medium Medium High high 802 1p Value 0 1 2 3 4 5 6 7 Configure Queuing Mode There are two different queuing modes ...

Page 103: ...eues are serviced Weight Weighted Round Robin shares bandwidth at the egress ports by using scheduling weights 1 2 4 8 for queues 1 through 4 respectively Configure Queuing Weighted Click the pull down menu to select values of Queue weighted for each port 4 4 8 2 QoS Control List The following screen page appears if you choose QoS Priority Configuration and then select QoS Control List ...

Page 104: ...pe Value View only field that shows QCL s current type value Traffic Class View only field that shows QCL s Traffic Class Click New to add a new QCL setting and then the following screen page appears Click Edit to view and edit registered QCL settings Click Delete to remove a current QCL setting ...

Page 105: ...ur preferred QCE Type you can further specify TCP UDP Port by selecting Specific or Range from the pull down menu Specific allows you to assign TCP UDP Port No On the other hand Range allows you to assign TCP UDP port range in TCP UDP Port Range field DSCP When you choose DSCP as your preferred QCE Type you can further specify DSCP value Traffic Class When you choose Ethernet Type VLAN ID UDP TCP ...

Page 106: ...ure Shaper Rate This allows users to specify each port s Shaper bandwidth 4 4 8 4 Storm Control Select the option Storm Control from the QoS Priority Configuration menu to set up the broadcast storm control parameters for ports and then the following screen page appears ...

Page 107: ...eding the specified threshold will then be dropped Three options of frame traffic are provided to allow users to enable or disable the storm control Unknown Unicast Rate Set storm control as the Unknown Unicast Rate Multicast Rate Set storm control as the Multicast Rate Broadcast Rate Set storm control as the Broadcast Rate 4 4 9 DSCP Remark To set up DSCP Remark select the option DSCP Remark from...

Page 108: ...ng is disabled Configure 802 1p Remark Select 802 1p Remark from the pull down menu of Select Setting This allows you to enable or disable 802 1p remarking for each port The default setting is disabled Configure Queue Mapping Select Queue Mapping from the pull down menu of Select Setting ...

Page 109: ... Port Mirroring In order to allow Target Port to mirror Source Port and enable traffic monitoring select the option Port Mirroring from the Switch Management menu and then the following screen page appears Source Port Choose Y enable or N disable from the pull down menu to enable or disable Target Port s mirroring on the TX and RX of Source port ...

Page 110: ...ackets between hosts connected to the switch and multicast routers in the network When a switch receives an IGMP report for a given multicast group from a host the switch adds the host s port number to the multicast list for that group When the switch hears an IGMP Leave it removes the host s port from the table entry IGMP snooping can reduce multicast traffic from streaming and other bandwidth in...

Page 111: ...ure each port s IGMP filter 4 4 11 1 IGMP Configuration Select the option IGMP Configuration from the IGMP Snooping menu and then the following screen page appears Snooping When enabled the Managed Switch will monitor network traffic and determine which hosts will receive multicast traffic Unregistered IPMC Flooding Set forwarding mode for unregistered not joined IP multicast traffic The traffic w...

Page 112: ...pecific queries The default setting is Disabled Router Ports When ports are connected to the IGMP administrative routers they should be set to Y Otherwise the default N will be applied 4 4 11 2 IGMP VLANID Configuration Select the option IGMP VLAN Configuration from the IGMP Snooping menu and then the following screen page with the ability information of IGMP Snooping and Querying in VLAN s appear...

Page 113: ...n VLAN can serve as the Querier which is responsible for asking hosts whether they want to receive multicast traffic 4 4 11 3 IPMC Segment Select the option IPMC Segment from the IGMP Snooping menu and then the following screen page with the ability information of IPMC Segment ID Name and IP Range appears ID View only field that shows the current registered ID number ...

Page 114: ...mber of current registered IPMC Segment Total This shows the total number of registered IPMC Segment Max This shows the maximum number available for IPMC Segment The maximum number is 400 Segment ID Specify a number from 1 400 for a new ID Segment Name Enter an identification name This field is limited to 20 characters IP Range Specify the multicast streams IP range for the registered segment The ...

Page 115: ...w to register a new IPMC Profile and then the following screen page appears Click Edit to edit the IPMC Profile settings Click Delete to remove a current IPMC Profile registration Current Total Max Profile Nums View only field Current This shows the number of current registered IPMC Profile Total This shows the number of total IPMC Profiles that are registered ...

Page 116: ... Snooping menu and then the following screen page appears IGMP Filter This option may enable or disable the IGMP filter The default setting is Disabled Channel Limit View only field that shows the maximum limit of each port s multicast streams Enable View only field that shows each port s IGMP filter is turned on or off Move the cursor to the port that you would like to edit click then the entry w...

Page 117: ...the port number that is currently configured IPMC Profile In IGMP filtering it only allows information specified in IPMC Profile fields to pass through The field for IPMC Profile name is from the entry registered in IPMC Profile option 4 4 12 Static Multicast Configuration Select the option Static Multicast Configuration from the Switch Management menu and then the following screen page appears ...

Page 118: ...r current multicast stream Forwarding port View only field that shows the forwarding port for current multicast stream Click New to register a new Static Multicast configuration and then the following screen page appears Click Edit to edit and view static multicast configuration settings Use Delete to remove a current Static Multicast configuration ...

Page 119: ...LANs intend to join or leave the multicast group simply by sending the IGMP Join or Leave message to a receiver port The receiver port that belongs to one of the multicast groups can receive multicast stream from the media server MVR Configuration Guidelines and Limitations Guidelines Enable IGMP global setting Enable MVR global setting Create MVR VLAN and indicate the Source port and Receive port...

Page 120: ...en the following screen page appears MVR Port Settings To enable or disable MRV global settings and create MVR VLAN to indicate the Source and Receive port MVR Group Create MVR Groups whose multicasting stream would belong to MVR VLAN 4 4 13 1 MVR Settings Select the option MVR Settings from the MVR Configuration menu and then the following screen page appears ...

Page 121: ... to register a new MVR VLAN ID and then the following screen page appears Click Edit to edit MVR settings Use Delete to remove a current MVR VLAN ID Current Total Max Multicast Nums View only field Current This shows the number of current registered MVR VLAN configuration Total This shows the total number of registered MVR VLAN configuration ...

Page 122: ...13 2 MVR Group Select the option MVR Group from the MVR Configuration menu and then the following screen page appears VLAN View only field that shows the current MVR VLAN ID Group Range View only field that shows the MVR Group Range Click New to register a new MVR Group and then the following screen page appears Click Edit to edit and view the MVR Group settings Click Delete to remove a current MV...

Page 123: ...customer port Port number 1 22 filtering functions DHCP Option 82 Guidelines The Managed Switch can add information about the source of client DHCP requests that relay to DHCP server by adding Relay Agent Information This helps provide authentication about the source of the requests The DHCP server can then provide an IP address based on this information The feature of DHCP Relay Agent Information...

Page 124: ...how each port s configuration DHCP Port Settings Customer port Port 1 22 DHCP snooping setting Filter Configuration Customer port Port 1 22 filtering setting Static IP Table Configuration To create static IP table for DHCP snooping setting 4 4 14 1 DHCP Option 82 Settings Select the option DHCP Option 82 Settings from the SKA Configuration menu and then the following screen page appears Opt82 Port...

Page 125: ... Opt82 Relay Agent Global setting Opt 82 Port Each port s Agent information When the symbol V is displayed the port is enabled Otherwise it is disabled Enable V Add Agent information Disable Forward Trust Port Setting When Trust Port is set to V enabled ...

Page 126: ...ives packets without Agent information and the Managed Switch will add Agent information 4 4 14 2 DHCP Port settings Select the option DHCP Port Settings from the SKA Configuration menu and then the following screen page appears Unlimited Non Limited Static IP or DHCP assigns IP Fixed IP Only Static IP The Static IP table must be created first DHCP DHCP server assigns IP address 4 4 14 3 Filter Co...

Page 127: ...conds Port Isolation If port isolation is set to Enabled the customer port port 1 22 can not communicate to each other IPv6 auto discovery DHCPv6 Enable to filter IPv6 auto discovery and DHCPv6 UPnP Enable to filter UPnP packets 4 4 14 4 Static IP Table Configuration Select the option Static IP Table Configuration from the SKA Configuration menu and then the following screen page appears ...

Page 128: ...current Mask address VLAN ID View only field that shows the VLAN ID Port View only field that shows the connection port number Click New to register a new Static IP address and then the following screen page appears Click Edit to edit and view Static IP Table settings Use Delete to remove a current Static IP address ...

Page 129: ...lt isolation Fault Detection Fault notification IEEE 802 1ag supports fault detection through Continuity Check Messages CCM CCM is somewhat like the keep alive message By default every 802 1ag capable network device ND sends out heart beat style CCM periodically Hence by configuring a list of expected existent remote 802 1ag capable NDs the local 802 1ag capable ND can detect the health status of ...

Page 130: ... timed out XconCCM The ND has received at least one CCM from either another VLAN or a lower MD Level whose CCM Interval has not yet timed out Select the folder CFM Configuration from the Switch Management menu and then the following screen page appears Maintenance Domain Settings To register or remove CFM Maintenance Domain Maintenance Association Settings To register or remove CFM Maintenance Ass...

Page 131: ... MD Name View only field that shows the current CFM Service Domain of the Managed Switch Format View only field that shows the current Domain type support string only MD Level View only field that shows the Service Level of Domain MHF View only field that shows the MIP Half Function or MEP Half Function Click New to register a new Maintenance Domain and then the following screen page appears Click...

Page 132: ...or a newly registered MD MD Format Currently the only supported MD format is String MD Level Specify a service level MHF Select an option for Maintenance Point Function from the pull down menu Default MHFs can be created for this VID on any Bridge Port through which the VID can pass Explicit MHFs can be created on CFM VLAN member port and only if there is a MEP at the lower active MD level on the ...

Page 133: ...y a MA name Format Currently the only supported format is String VID Specify a registered VLAN ID for MA CCM Interval Specify the time period to send connectivity check message CCM MHF View only field that shows the Defer Default Explicit or None Click New to register a new Maintenance Association and then the following page appears Click Edit to edit and view Maintenance Association settings Clic...

Page 134: ...ecify a registered VLAN ID for MA CCM Interval Configure the CCM Interval time from the pull down menu MHF Select an option for Maintenance Point Function from the pull down menu Defer The control of MHF creation is deferred to the corresponding variable in the enclosing Maintenance Domain Default MHFs can be created for this VID on any Bridge Port through which the VID can pass Explicit MHFs can ...

Page 135: ...D MEP LIST View only field that shows a list of remote MEP IDs MEP ID Specify the remote MEP ID which you want to add or remove Status Idle No actions will be taken Add Insert a specified MEP ID to the MEP List Delete Remove a specified MEP ID from the MEP List 4 4 15 4 Maintenance End Point Settings Select the option Maintenance End Point Settings from the CFM Configuration menu and then the foll...

Page 136: ...ntenance Point direction Port Select a bridge port of the Maintenance Point Admin State To enable or disable Admin State CCM State To enable or disable CCM State CCM LTM Priority To configure the CCM LTM priority from the pull down menu Lowest Priority To configure the lowest priority from the pull down menu Fault Alarm Time Specify the Fault Alarm Time Fault Reset Time Specify the Fault Reset Tim...

Page 137: ...C for loopback test Messages Number Specify the LBM Messages number for loopback test Data Size Specify the Data Size for loopback test VLAN Priority Specify the VLAN priority bit for loopback test Drop Eligible Bit Select True or False from the pull down menu True Frames will be dropped first when the transfer rate is exceeded because they are less important False Frames will not be dropped first...

Page 138: ...ent registered Maintenance Domain Association Select a current registered Maintenance Association Source MEP View only field that shows the current MEP ID Target MAC MEP ID Specify the target MAC or MEP ID for linktrace test Flag Select FDB Only or None from the pull down menu Hop Count Specify the Hop count for linktrace test Send linktrace Start linktrace test ...

Page 139: ...fy the Number from 2 100 VLAN Priority Specify the VLAN priority bit for loopback test Send Message Start Delay Measurement 4 4 16 Access Control List Management ACLM Creating an access control list allows users to define who has the authority to access information or perform tasks on the network In the Managed Switch users can establish rules applied to port numbers to permit or deny actions Sele...

Page 140: ...miter Disable or enable rate limiter Port Copy Send a copy to the desired port Shutdown If enabled the Managed Switch will shutdown interface Counter View only filed that shows how many packets conform to MAC and VLAN parameters ACL Rate Limiter Configuration When Rate Limiter is enabled in ACL Configuration rate of each Rate Limiter can be further specified ...

Page 141: ...e for each Rate Limiter ID ACL Configuration Click New to add a new ACL Configuration The screen page is shown below Click Delete to remove a registered ACL configuration Click Edit to view and edit a registered ACL configuration ...

Page 142: ...ID Specify a VLAN ID Tag Priority Select the tag priority from the pull down mneu When information conforms to MAC and VLAN parameters then actions set in Frame Type Action Rate Limiter Port Copy and Shutdown will be taken into consideration Ingress Port Select Policy 1 8 or the port number from the pull down menu Frame Type Select the desired frame type ...

Page 143: ... folder Switch Monitor from the Console main menu and then the following screen page appears 1 Switch Port State View current port media type port state etc 2 Port Traffic Statistics View each port s frames and bytes received or sent utilization etc 3 Port Packet Error Statistics View each port s traffic condition of error packets e g CRC fragment Jabber etc 4 Port Packet Analysis Statistics View ...

Page 144: ...ew the current port s CFM information e g CFM stack CFM statistics Maintenance End Point Remote Maintenance End Points Linktrace Reply 4 5 1 Switch Port State In order to view the real time port status of the Managed Switch select Switch Port State from the Switch Monitor menu and then the following screen page appears Port Number The number of the port Media Type The media type of the port either...

Page 145: ...ssarily relayed Forwarding A port in this state participates in frame relay Packets can be forwarded only when port state is forwarding Link State The current link status of the port either up or down Speed Mbps The current operation speed of ports which can be 10M 100M or 1000M Duplex The current operation Duplex mode of the port either Full or Half Flow Control The current state of Flow Control ...

Page 146: ...ort of total bandwidth Clear All This will clear all port s counter values and be set back to zero 4 5 3 Port Packet Error Port Packet Error Statistics mode counters allow users to view the port error of the Managed Switch The event mode counter is calculated since the last time that counter was reset or cleared Select Port Packet Error Statistics from the Switch Monitor menu and then the followin...

Page 147: ...ers to view the port analysis history of the Managed Switch Event mode counters are calculated since the last time that counter was reset or cleared Select Port Packet Analysis Statistics from the Switch Monitor menu and then the following screen page appears Select Choose the Packet Error Statistics from the pull down menu Frames 64 Bytes 64 bytes frames received Frames 65 127 Bytes 65 127 bytes ...

Page 148: ... allows users to view a list of all LACP ports information Select LACP Port Status from the LACP monitor menu and then the following screen page appears In this page you can find the following information of a LACP port Port Number The number of the port Partner ID The current operational key for the LACP group In LACP mode link aggregation control protocol data unit LACPDU is used for exchanging ...

Page 149: ...tic LACP aggregation the selected ports share the same operational key Partner Port The corresponding port numbers that connect to the partner switch in LACP mode 4 5 5 2 LACP Statistics In order to view the real time LACP statistics status of the Managed Switch select LACP Statistics from the LACP Monitor menu and then the following screen page appears Port LACP packets LACPDU transmitted or rece...

Page 150: ...then the following screen page appears In this page you can find the following information in a RSTP VLAN bridge Update Update the current status VLAN ID VID of the specific VLAN Bridge ID RSTP Bridge ID of the Managed Switch in a specific VLAN Max Age Max Age setting of the Managed Switch in a specific VLAN Hello Time Hello Time setting of the Managed Switch in a specific VLAN Forward Delay The M...

Page 151: ...lowing information of a RSTP port Port Number The number of the port VLAN ID The VID of the VLAN that this port belongs to Path Cost The Path Cost of the port Edge Port Yes is displayed if the port is the Edge port connecting to an end station and does not receive BPDU P2p Port Yes is displayed if the port link is connected to another STP device Protocol Display RSTP or STP Role Display the Role o...

Page 152: ...n packets from current port RSTP Received The total received RSTP packets from current port STP Received The total received STP packets from current port TCN Received The total received TCN packets from current port Illegal Received The total received illegal packets from current port Unknown Received The total received unknown packets from current port 4 5 7 802 1X Monitor 4 5 7 1 80 2 1X Port St...

Page 153: ...ast Source Display the number of the port s Last Source Last ID Display the number of the port s Last ID 4 5 7 2 802 1X Statistics In order to view the real time 802 1x port statistics status of the Managed Switch select 802 1x Statistics from the 802 1x Monitor menu and then the following screen page shows up Select the port number from the pull down menu to view statistics ...

Page 154: ... to view a list of IGMP queries information in VLAN s such as VLAN ID Querier and Queries Transmitted Received packets Select IGMP Snooping Status from the IGMP Monitor menu and then the following screen page appears Update Click Update to update the table VLAN ID VID of the specific VLAN ...

Page 155: ... the VLAN Queries Transmitted The total IGMP general queries transmitted will be sent to IGMP hosts Queries Received The total received IGMP general queries from IGMP querier v1 Reports IGMP Version 1 reports v2 Reports IGMP Version 2 reports v3 Reports IGMP Version 3 reports v2 Leaves IGMP Version 2 leaves 4 5 8 2 IGMP Group Table In order to view the real time IGMP multicast group status of the ...

Page 156: ... above shows the MAC addresses learned from each port of the Managed Switch Click Update to update the MAC Address Table Click Clear to clear the MAC Address table 4 5 10 SFP Information 4 5 10 1 SFP Port Information SFP Information displays each port s slide in SFP Transceiver information e g Speed Length Vendor Name Vendor PN Vendor SN and detection Temperature Voltage TX Bias etc Select SFP Por...

Page 157: ... of the slide in SFP Transceiver Vendor Name Vendor name of the slide in SFP Transceiver Vendor PN Vendor PN of the slide in SFP Transceiver Vendor SN Vendor SN of the slide in SFP Transceiver 4 5 10 2 SFP Port State Select SFP Port State from the SFP Information menu and then the following screen page appears ...

Page 158: ... voltage TX Bias mA The Slide in SFP module operation current TX Power dbm The Slide in SFP module optical Transmission power RX Power dbm The Slide in SFP module optical Receiver power 4 5 11 DCHP Snooping DHCP Snooping displays the Managed Switch s DHCP Snooping table Select DHCP Snooping from the Switch Monitor menu and then the following screen page appears ...

Page 159: ...nt lease time 4 5 12 CFM Information Ethernet Connectivity Fault Management CFM is an end to end and service to service Ethernet layer operations administration and maintenance OAM 802 1ag protocol It includes practical connectivity monitoring fault verification and fault isolation for large Ethernet metropolitan area networks MANs and WANs As its name implies IEEE 802 1ag focuses on the connectiv...

Page 160: ...ault isolation through Linktrace Messages LTM and Linktrace Reply LTR The LTM LTR mechanism is similar to the trace route function in the IP network However since the interfaces of an ND in an Ethernet network may not possess their individual IP address the operator can not achieve fault isolation by trace route in such a network environment IEEE 802 1ag also defines the following network error st...

Page 161: ...ield that shows the MAC address of this Managed Switch Maintenance Domain View only field that shows the MD of the selected port Maintenance Association View only field that shows the MA of the selected port MD Level View only field that shows the MD level of the selected port MEP ID View only field that shows the MEP ID of the selected port 4 5 12 2 CFM Statistics Select CFM Statistics from the C...

Page 162: ...on Select a current Domain from pull down menu MEP View only shows current MEP ID 4 5 12 3 Maintenance End Point Select Maintenance End Point from the CFM Information menu and then the following screen page appears Domain Select a current Maintenance Domain from pull down menu ...

Page 163: ...e End Points from the CFM Information menu and then the following screen page appears Domain Select a current Maintenance Domain from pull down menu Association Select a current Domain from pull down menu MEP View only shows current MEP ID 4 5 12 5 Linktrace Reply Select Linktrace Reply from the CFM Information menu and then the following screen page appears ...

Page 164: ...on ID Select a transaction ID from the pull down menu Target MAC MEP ID When you select a transaction ID the corresponding target MAC MEP ID that runs a linktrace testing will be shown 4 6 System Utility System Utility allows users to easily operate and maintain the system Select the folder System Utility from the main menu and then the following screen page appears ...

Page 165: ...ged Switch 3 Load Factory Setting Load Factory Setting will set the configuration of the Managed Switch back to the factory default settings The IP and Gateway addresses will be set to the factory default as well 4 Load Factory Setting Except Network Configuration Selecting this function will also restore the configuration of the Managed Switch to its original factory default settings However this...

Page 166: ... FTP clients Users may save or restore their configuration and update their Firmware on line Select Update from the System Utility menu and then the following screen page appears Protocol Select the preferred protocol either FTP or TFTP File Type Select the file to process either Firmware or Configuration ...

Page 167: ...mpleted a process completed message will pop up to remind users Click Stop to abort the current operation Select Update then press Enter to instruct the Managed Switch to update existing firmware configuration to the latest firmware configuration received After a successful update message pops up the Managed Switch will need a reset to make changes effective 4 6 3 Load Factory Settings Load Factor...

Page 168: ...xcept Network Configuration is very useful when network administrators need to re configure the system REMOTELY because conventional Factory Reset will bring network settings back to default and lose all network connections Select Load Factory Setting Except Network Configuration from the System Utility menu the following screen page shows up Click OK to start loading factory settings except netwo...

Page 169: ... Select FTP or TFTP server to backup Server Address This field is for FTP or TFTP server IP address User Name This field is for FTP server only Password This field is for FTP server only File Directory The place where backup files will be saved to File Name The name of backup files which will be saved by date 4 7 Save Configuration In order to save configuration setting permanently users need to s...

Page 170: ... configuration 4 8 Reset System After any configuration changes Reset System can make changes effective Select Reset System from the Console main menu and then the following screen page appears Click OK to perform System Reset ...

Reviews: