background image

1

27” Domestic Dryer-Technical Information 

NED7200TW, NGD7200TW

• Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or

repair of this unit. 

•  Refer to Service Manual 16025911 for detailed installation, operating, testing, troubleshooting, and disassembly

instructions. 

CAUTION

All safety information must be followed as provided in Service Manual 16025911.

WARNING

To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless
testing requires power. 

FEATURES

Capacity (cu.ft.)
Cycles
Controls
Dryness Control
Intellidry Sensor

Outboarded Adj. Degree of Dryness

Less Dry
Normal Dry
More Dry
Temperature Settings, not inc. Air Fluff

Fabric Selections

Regular Cycle
Wrinkle Control Cycle w/Cool Down
Delicates Gabric Selection
Sound-Silencing Package
Time Dry
Air Fluff
Wrinkle Release
Wrinkle Prevent
Tumbler
End of Cycle Chime
Drum Light
Extra Large Reversible Door Opening
4 Point Suspension System

MDG/E6700

7.0

10

LED

IntelliDry

3 LEDs

*
*
*

L, M, R

*
*
*
*

99 min

*
*
*

Powdercoat

on/off

*

15 ” Glass

*

Heating Element
Electronic lgnition w/ Safety Shun-OFF
Valvee (Gas Only)
Venting
CFM
Color A vailability

DIMENSIONS

Pedestal/Riser (MAL 1800AX*)
Dryer Width
Dryer Depth
Dryer Height

5300w

22,000 btu

3 way E/G

180

W

13 ”
27 ”

30.375 ”

38 ”

DC68-02029F

W10162408

Summary of Contents for NED7200TW

Page 1: ...pacity cu ft Cycles Controls Dryness Control Intellidry Sensor Outboarded Adj Degree of Dryness Less Dry Normal Dry More Dry Temperature Settings not inc Air Fluff Fabric Selections Regular Cycle Wrinkle Control Cycle w Cool Down Delicates Gabric Selection Sound Silencing Package Time Dry Air Fluff Wrinkle Release Wrinkle Prevent Tumbler End of Cycle Chime Drum Light Extra Large Reversible Door Op...

Page 2: ...en Regulating thermostat trips easily or is open Membrane switch open Check Thermistor Will Not Dry Gas Models Poor Gas lgnition When the dryer is operated on a heat setting the igniter should be energized and burner shall fire within 45 seconds at 120 VAC The failure of a component in this system will usually be indicated by one of three symptoms The igniter does not glow If the igniter does not ...

Page 3: ...ice Mode or repeat the Chime and Temperature sequence Diagnostic Tests The following table lists the various tests available while in the Service Mode Before advancing to the temperature in next test the current test running must be terminated Press the following keys to access System Check Mode While in Service Mode pressing the Time and Wrinkle Prevent keys for 3 seconds will put the dryer into ...

Page 4: ...rvice Mode and pressing Wrinkle Prevent A d will be displayed Rotate the Cycle Selector Knob in either direction to step through the list of codes one code at a time Once an initial direction is selected by the user either Clockwise or Counterclockwise subsequent movements of the knob in the same direction will show older codes If the user changes direction and turns the knob in the opposite direc...

Page 5: ...tuck Run membrane pad check and replace console w membrane pad if necessary Display Description Trigger Action Taken tS Dryer Thermistor Short Sensed The Thermistor resistance is very low Check for Clogged lint screen Restricted vent system Check Thermistor resistance Check for diagnostic code 1 do Door Open Running the dryer with door open Check for Close the door and run the dryer Loose or open ...

Page 6: ...Door switch button out Terminal COM NC 1 3 1Ω Terminal COM NO 1 2 Ω 2 Door switch button in Terminal COM NC 1 3 Ω Terminal COM NO 1 2 1Ω Belt Cut off S W Lever open Resistance value 1Ω Lever push Resistance value Ω Lamp resistance 80 100 Ω Violet gray Motor Electronic GAS Contacts WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless t...

Page 7: ...ance across terminal indicates a closed switch Less than 1 ohm Centrifugal Switch Motor TH2 Hi Limit Gas Check across terminals 1 and 3 Booster Coil 550 ohms Check across terminals 1 and 2 Holding Coil 1350 ohms Check across terminals 2 and 3 Both coils in series 1900 ohmsCheck across terminals 4 and 5 Secondary Coil 1300 ohms Gas Valve Radiant Sensor Gas 230 180 F 110 82 C 25A HI limit ...

Page 8: ...Input Blue Black wire on Heater Relay Sensor Bars Disconnect harness and test Pink wire Pin 4 to Orange wire Pin 5 Approx Ω without laundry Approx 190 Ω 10 with wet clothes Cycling Thermostat Disconnect harness and test Blue wire Pin 2 to Red wire Pin 6 Approx 10 K Ω at 25 C 77 F 120VAC Motor input Brown 1P on Motor relay White wire Sensor Bars temperature sensor check 6 1 CN3 CN6 MOTOR HEATER ...

Page 9: ...W10162408 9 Wiring Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires power ...

Page 10: ...W10162408 10 Wiring Schematic WARNING To avoid risk of electrical shock personal injury or death disconnect power to dryer before servicing unless testing requires power ...

Page 11: ...ne du degré de séchage Less Dry séchage faible Normal Dry séchage normal More Dry séchage élevé Réglages de température sans Air Fluff air froid Sélections qualités des tissus Cycle Regular cycle normal Cycle Wrinkle Control sans froissage avec refroidissement Cycle Delicates délicats Ensemble de réduction du bruit Temps de séchage Air Fluff air froid Wrinkle Release désactiver sans froissage Prév...

Page 12: ...stat de régulation se déclenche facilement ou est ouvert Le commutateur à membrane est ouvert Contrôler la thermistance Ne sèche pas modèles à gaz L allumage du gaz est faible Lorsque la sécheuse fonctionne en mode chaleur l allumeur doit être alimenté et le brûleur se met en marche dans les 45 secondes à une tension de 120 V c a Lorsqu un des composants du système est défectueux cela se manifeste...

Page 13: ...service les données de la barre de contact du détecteur s affichent Désactivation du mode de service Pour quitter le mode de service appuyez sur la touche OFF ou répétez la séquence Chime et Temperature Essais de diagnostic Le tableau suivant présente les différents essais disponibles en mode de service Avant de passer à l essai suivant celui qui est en cours doit être terminé Appuyez sur les touc...

Page 14: ... codes de diagnostic en activant le mode de service et en appuyant sur la touche Wrinkle Prevent La lettre d s affiche La rotation du sélecteur de cycle dans un sens ou l autre permet de parcourir la liste des codes un à la fois sans boucle Lorsque l utilisateur choisit un sens soit horaire ou antihoraire les déplacements subséquents du sélecteur dans le même sens permettent d afficher les anciens...

Page 15: ...éant Code Description Déclencheur Mesure à prendre tS Court circuit de la thermistance de la sécheuse La résistance de la thermistance est très faible Vérifiez si le filtre à charpie est bouché si le système de ventilation est obstrué la résistance de la thermistance la présence du code de diagnostic 1 do La porte est ouverte Fonctionneme nt de la sécheuse avec la porte ouverte Vérifiez en fermant...

Page 16: ...inférieure à 1 Ω Borne COM NO 1 2 Ω 2 Interrupteur de porte enclenché Marche Borne COM NC 1 3 Ω Borne COM NO 1 2 inférieure à 1 Ω Interrupteur d arrêt de la courroie levier ouvert Valeur de résistance inférieure à 1 Ω Levier enclenché Valeur de résistance Ω Résistance de la lampe de 80 100 Ω violet et gris Moteur électronique et gaz Éléments de contact AVERTISSEMENT Pour éviter tout risque d élect...

Page 17: ... interrupteur est fermé Moins de 1 ohm Interrupteur centrifuge moteur Limite sugérieure TH2 gaz Vérifier aux bornes 1 et 3 bobine de démarrage 550 ohms Vérifier aux bornes 1 et 2 bobine de maintien 1 350 ohms Vérifier aux bornes 2 et 3 deux bobines en série 1 900 ohms Vérifier aux bornes 4 et 5 bobine secondaire 1 300 ohms Soupape de gaz Capteur d énergie radiante gaz INTERRUPTEUR ILLUSTRÉ EN POSI...

Page 18: ...Débrancher le faisceau et effectuer une vérification entre la broche 4 du fil rose et la broche 5 du fil orange Approx Ω sans charge de vêtements Approx 190 Ω 10 avec des vêtements humides Thermostat à fonctionnement cyclique Débrancher le faisceau et effectuer une vérification entre la broche 2 du fil bleu et la broche 6 du fil rouge Approx 10 kilohms à 25 C 77 F 120 V c a Entrée de moteur Brun 1...

Page 19: ...08 19 Schéma de câblage AVERTISSEMENT Pour éviter tout risque d électrocution de blessure ou de mort débranchez la sécheuse avant de la réparer à moins que l alimentation ne soit nécessaire à des fins d essai ...

Page 20: ...08 20 Schéma de câblage AVERTISSEMENT Pour éviter tout risque d électrocution de blessure ou de mort débranchez la sécheuse avant de la réparer à moins que l alimentation ne soit nécessaire à des fins d essai ...