Summary of Contents for CS

Page 1: ...ard it will contact the index wheel driver releasing the index wheel The index wheel return spring will rotate the index wheel in a counterclockwise direction It will continue rotating until the switch actuator arm catches a movable return stop This stops the rotation of the index wheel for the first slide actuation INDEX NOTE Some coin slides may require breaking and removing the tab on the actua...

Page 2: ... used to set the mechanism to accumulate two time settings totaling 53 minutes of dry time accumulative setting 1 Remove the movable return stops from the coin box 3 Install the movable return stop in position D Remove the time adjustment peg from position C as set in manufacturing and install in position B See charts for additional information MOVABLE RETURN STOP IN POSITION D TIME ADJUSTMENT PEG...

Page 3: ... be placed in adjacent positions because the lower ears will interfere Actual time may very depending on local voltage and Hz LOCKS AND KEYS On CS PS models the control service door and lock are NOT provided with the dryer Keys and locks should be ordered from your commercial distributor INSTALLING COIN BOX LOCK Assemble the spring washer over the threaded portion of the lock and insert into the c...

Page 4: ... the display Accumulator Pricing If the price is set to one coin 1 then accumulator mode is in effect stacked PD models also require Fixed Cycle with Top Off option to be selected Cycle time can be purchased one coin at a time PD and PS models up to the maximum time of 99 minutes Stacked PD machines will credit all money to a cycle with a single button press while in accumulator pricing Fixed Cycl...

Page 5: ... 3 06 3 SPECIAL CYCLE PRICE 06 Represents the number of quarters coin 1 may adjust from 0 39 See VALUE OF COIN 1 b 05 Advance from 0 39 by pressing WHITES COLORS Presently set for 6 quarters 1 50 PR PN MODELS Presently set for 0 quarters Press PERMANENT PRESS key pad once to advance to next code 4 05 5 00 6 00 7 00 8 00 4 05 5 00 6 00 7 00 8 00 9 10 9 10 SPECIAL DRY TIME Represents the number of m...

Page 6: ...isabled while blockage persists Voltage detected below 90vac for 8 seconds Lower dryer motor sense circuit error on control board or due to power line interference lower dryer cycles and lower dryer display disabled until diagnostic code is manually cleared Blocked coin 2 or coin drop control circuit failure coin recognition and price display disabled while blockage persists Upper dryer motor sens...