background image

MT6250 User’s Manual V1.3

 

 
 
 
 
 
 

MT6250 

2D Fixed Mount Scanner 

User’s Manual 

 
 
 
 
 
 
 
 
 
 
 
 

Version 1.3 

 

 

 

 

 

 

 

 

 

 

 

     DATE: 2022/09/08 

 

 

Summary of Contents for MT6250

Page 1: ...MT6250 User s Manual V1 3 MT6250 2D Fixed Mount Scanner User s Manual Version 1 3 DATE 2022 09 08...

Page 2: ...GOOD READ INDICATOR 11 Beep Tone 11 Indicator LED 11 DATA FORMAT 11 UTF 8 to Unicode Conversion 11 HT CR ESC Converts to TAB ENTER ESCAPE 12 Function Code Conversion 12 Control Code Output Method 13 N...

Page 3: ...TERMINATOR 29 CHAPTER 6 SYMBOLOGIES 30 GENERAL SETTINGS 30 UPC A 31 Enable Disable UPC A 31 Check Digit 31 UPC A to EAN 13 31 UPC E0 32 Enable Disable UPC E0 32 Check Digit 32 UPC E0 to UPC A 32 EAN 8...

Page 4: ...erleaved 2 of 5 45 Verification 45 Interleaved 2 of 5 Min Max Length 46 MATRIX 2 OF 5 47 Enable Disable Matrix 2 of 5 47 Matrix2 of 5 Min Max Length 47 INDUSTRIAL 2 OF 5 48 Enable Disable Industrial 2...

Page 5: ...3 MAXICODE 54 Enable Disable MaxiCode 54 CHAPTER 7 APPENDIX 55 APPENDIX NUMBERS 55 APPENDIX UPPER CASE ALPHABETS 56 APPENDIX LOWER CASE ALPHABETS 58 APPENDIX CONTROL CODES 60 APPENDIX SYMBOLS 62 APPEN...

Page 6: ...ggedized housing and has RS232 or USB interface available to fulfill both industrial and commercial connectivity requirements Product Requirement Model Interface Version MT6250U USB HID USB VCP HM3 r...

Page 7: ...U USB Type A MT6250R D sub 9 Cable 90cm Fixed Cable Trigger Auto sensing Software Trigger Indicator LED Buzzer Electrical Operation Voltage 5 VDC 5 Working Current 370mA Standby Current 200mA Connecti...

Page 8: ...TBA Safety Approval EN IEC62471 Exempt Group Environmental WEEE RoHS 2 0 Beeper Indication Beeper Status Single long beep Power up Single short beep Good read Two beeps Successful setup Three short b...

Page 9: ...pe A Male Pin Signal 1 5VCC 2 Data 3 Data 4 GND RS232 Connection MT6250R RS232 D Sub 9 Female Pin Signal 2 TXD Out 3 RXD In 5 GND 7 CTS In 8 RTS Out 9 5VCC Note Power can be supplied either directly t...

Page 10: ...s by scanning configuration barcodes in this manual Enable Barcode Configurability Disable Barcode Configurability Factory Default Scanning below configuration barcode will reset all parameters to fac...

Page 11: ...MT6250 User s Manual V1 3 11 Good Read Indicator Beep Tone Off Beep Low 2 0KHz Beep Medium 2 7KHz Beep High 4 0KHz Indicator LED Off On Data Format UTF 8 to Unicode Conversion Off On...

Page 12: ...is transmitted as 0x09 0x0D and 0x1B respectively 2 When enabled HT I CR M and ESC A is transmitted as TAB ENTER and ESCAPE on keyboard respectively Function Code Conversion Off On Note Once disabled...

Page 13: ...ess I key and release Ctrl key and I key c Enter F Press F key Since Ctrl I is shortcut for italicizing text in some software applications the result of above output sequence can be a regular A plus a...

Page 14: ...m Alt 1 3 SO 0E 14 Ctrl n Alt 1 4 SI 0F 15 Ctrl o Alt 1 5 DLE 10 16 Ctrl p Alt 1 6 DC1 11 17 Ctrl q Alt 1 7 DC2 12 18 Ctrl r Alt 1 8 DC3 13 19 Ctrl s Alt 1 9 DC4 14 20 Ctrl t Alt 2 0 NAK 15 21 Ctrl u...

Page 15: ...can NUMERIC KEY if you want to use the keys on the numeric keypad 2 If you select NUMERIC KEY the Num Lock status of the physical keyboard should be ON OPOS Off On Note To function properly with OPOS...

Page 16: ...D indicator is ON or OFF output will be always the same as the Original barcode In other words what you see is what output is Imaging Settings Inverse Barcode Disable Inverse Barcode Enable Inverse Ba...

Page 17: ...rcode will set MT6250U USB cable to USB HID interface in which the scanner becomes an HID keyboard device Do not scan below configuration barcode with MT6250R RS232 cable USB HID Keyboard Layout Engli...

Page 18: ...MT6250 User s Manual V1 3 18 Italian French German Swiss German Swiss French Swedish Czech QWERTZ Czech QWERTY Norwegian Belgian Portuguese Slovak Brazilian QWERTY Canadian Traditional...

Page 19: ...character Delay Default 0ms Example Set Intercharacter Delay to 8ms Step1 Scan Set Intercharacter Delay Step2 Scan 0 0 8 in Appendix Numbers Step3 Scan Set Intercharacter Delay Interblock Delay The co...

Page 20: ...e with the host via USB Virtual COM Normally virtual COM port can be recognized by the host If it is not recognizable by the host please download VCP driver from our website Do not scan below configur...

Page 21: ...MT6250 User s Manual V1 3 21 4800 9600 19200 38400 57600 115200 Data Bits Parity 8 Bits Even 8 Bits Odd 8 Bits Space 8 Bits Mark 8 Bits None 7 Bits Even...

Page 22: ...MT6250 User s Manual V1 3 22 7 Bits Odd 7 Bits Space 7 Bits Mark Stop Bits 1 Stop Bit 2 Stop Bits Handshaking None RTS enable at Power On RTS enable with Communication...

Page 23: ...trol Timeout Default 1 sec Step1 Scan Flow Control Timeout Step2 Scan 3 digits 000 255 from in Appendix Numbers 000 unlimited 001 1 Sec 002 2 Sec 003 3 Sec 004 4 Sec 254 254 Sec 255 255 Sec Default 00...

Page 24: ...de In Infrared Auto sensing Mode the scanner starts scanning whene an object is detected within the Infrared Auto sensing Range The scanner will scan again only after the object barcode scanned previo...

Page 25: ...r approx 13cm auto sensing range 2 Middle approx 20cm auto sensing range Default 3 Far approx 27cm auto sensing range 4 Auto sensing range may vary depending on the surface reflectiveness of the objec...

Page 26: ...ID When Factory ID is enabled a Factory ID see Appendix Factory ID will be added to the beginning of each barcode data When Set ID is enabled a user defined ID see Set ID will be added to the beginni...

Page 27: ...D Code128 Set ID EAN 13 Set ID EAN 8 Set ID UPC A Set ID UPC E0 Set ID Interleaved 2 of 5 Set ID Matrix 2 of 5 Set ID Industrial 2 of 5 Set ID Code93 Set ID Code11 Set ID MSI Plessey Set ID GS1 Databa...

Page 28: ...ple Set Code39 Set ID as XY Step1 Scan Set ID Code39 Step2 Scan X Y in Appendix Upper Case Alphabets Step3 Scan Set ID Code39 Data Length Send Data Length Off Send Data Length On Preamble Preamble can...

Page 29: ...Scan Set Preamble Postamble Postamble can be up to 16 bytes of data Set Postamble Example Set XYZ123 as Postamble Step 1 Scan Set Postamble Step 2 Scan X Y Z 1 2 3 in Appendix Upper Case Alphabets Nu...

Page 30: ...1 3 30 CR CR LF TAB Space ESC Chapter 6 Symbologies General Settings Enable All Symbologies Disable All Symbologies Enable All 1D Symbologies Disable All 1D Symbologies Enable All 2D Symbologies Disab...

Page 31: ...all symbologies are disabled configuration barcodes are still readable UPC A Enable Disable UPC A Enable UPC A Disable UPC A Check Digit Send Check Digit Not Send Check Digit UPC A to EAN 13 Enable U...

Page 32: ...MT6250 User s Manual V1 3 32 UPC E0 Enable Disable UPC E0 Enable UPC E0 Disable UPC E0 Check Digit Send Check Digit Not Send Check Digit UPC E0 to UPC A Enable UPC E0 to UPC A Disable UPC E0 to UPC A...

Page 33: ...MT6250 User s Manual V1 3 33 EAN 8 Enable Disable EAN 8 Enable EAN 8 Disable EAN 8 Check Digit Not Send Check Digit Send Check Digit...

Page 34: ...MT6250 User s Manual V1 3 34 EAN 13 Enable Disable EAN 13 Enable EAN 13 Disable EAN 13 Check Digit Not Send Check Digit Send Check Digit ISBN On Off ISSN On Off...

Page 35: ...MT6250 User s Manual V1 3 35 UPC EAN Supplement Enable 2 5 digit Supplement Disable 2 5 digit Supplement Auto 2 5 digit Supplement...

Page 36: ...MT6250 User s Manual V1 3 36 Code 128 Enable Disable Code 128 Enable Code 128 Disable Code 128 GS1 128 UCC EAN 128 Enable Disable GS1 128 Enable GS1 128 Disable GS1 128...

Page 37: ...Default 50 Example Set Min Length as 8 Max Length as 12 for Code128 GS1 128 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan...

Page 38: ...MT6250 User s Manual V1 3 38 Code 39 Enable Disable Code 39 Enable Code 39 Disable Code 39 Verification Disable CDV CDV Send CD CDV Not Send CD Start Stop Not Send Start Stop Send Start Stop...

Page 39: ...Length Default 01 Set Max Length Default 50 Example Set Min Length as 8 Max Length as 12 for Code39 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan S...

Page 40: ...able Disable Code 32 Enable Code 32 Disable Code 32 Notw Please make sure Code39 is enabled with verification disabled before enabling Code32 Leading Tailing Not Send Leading Tailing Send Leading Only...

Page 41: ...ngth Default 04 Set Max Length Default 50 Example Set Min Length as 8 Max Length as 12 for Code93 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set...

Page 42: ...MT6250 User s Manual V1 3 42 Code 11 Enable Disable Code 11 Enable Code 11 Disable Code 11 Verification Disable CDV Single Digit Double Digits Check Digit Send Check Digit Not Send Check Digit...

Page 43: ...Default 50 Example Set Min Length as 8 Max Length as 12 for Code11 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2 in Ap...

Page 44: ...Min Max Length Set Min Length Default 04 Set Max Length Default 50 Example Set Min Length as 8 Max Length as 12 for Codabar Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set...

Page 45: ...MT6250 User s Manual V1 3 45 Interleaved 2 of 5 Enable Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Verification Disable CDV CDV Send CD CDV Not Send CD...

Page 46: ...Default 50 Example Set Min Length as 8 Max Length as 12 for Interleaved 2 of 5 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Sc...

Page 47: ...Set Min Length Default 04 Set Max Length Default 24 Example Set Min Length as 8 Max Length as 12 for Matrix 2 of 5 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Leng...

Page 48: ...ax Length Set Min Length Default 04 Set Max Length Default 24 Example Set Min Length as 8 Max Length as 12 for Industrial 2 of 5 Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan...

Page 49: ...V1 3 49 MSI Plessey Enable Disable MSI Plessey Enable MSI Plessey Disable MSI Plessey Verification Send Check Digit Not Send Check Digit Single Check Digit MOD10 Double Check Digits MOD10 Double Chec...

Page 50: ...Default 50 Example Set Min Length as 8 Max Length as 12 for MSI Plessey Step1 Scan Set Min Length Step2 Scan 0 8 in Appendix Numbers Step3 Scan Set Min Length Step4 Scan Set Max Length Step5 Scan 1 2...

Page 51: ...GS1 DataBar Disable GS1 DataBar GS1 DataBar Limited RSS Limited Enable Disable GS1 DataBar Limited Enable GS1 DataBar Limited Disable GS1 DataBar Limited GS1 DataBar Expanded RSS Expanded Enable Disa...

Page 52: ...2 QR Code Enable Disable QR Code Enable QR Code Disable QR Code Micro QR Code Enable Disable Micro QR Code Enable Micro QR Code Disable Micro QR Code Data Matrix Enable Disable Data Matrix Enable Data...

Page 53: ...er s Manual V1 3 53 PDF417 Enable Disable PDF417 Enable PDF417 Disable PDF417 MicroPDF417 Enable Disable MicroPDF417 Enable MicroPDF417 Disable MicroPDF417 Aztec Enable Disable Aztec Enable Aztec Disa...

Page 54: ...MT6250 User s Manual V1 3 54 MaxiCode Enable Disable MaxiCode Enable MaxiCode Disable MaxiCode...

Page 55: ...MT6250 User s Manual V1 3 55 Chapter 7 Appendix Appendix Numbers 0 1 2 3 4 5 6 7 8 9...

Page 56: ...MT6250 User s Manual V1 3 56 Appendix Upper Case Alphabets A B C D E F G H I J K L M N O P...

Page 57: ...MT6250 User s Manual V1 3 57 Q R S T U V W X Y Z...

Page 58: ...MT6250 User s Manual V1 3 58 Appendix Lower Case Alphabets a b c d e f g h i j k l m n o p...

Page 59: ...MT6250 User s Manual V1 3 59 q r s t u v w x y z...

Page 60: ...MT6250 User s Manual V1 3 60 Appendix Control Codes NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI...

Page 61: ...MT6250 User s Manual V1 3 61 DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US...

Page 62: ...MT6250 User s Manual V1 3 62 Appendix Symbols _...

Page 63: ...MT6250 User s Manual V1 3 63...

Page 64: ...MT6250 User s Manual V1 3 64 SP DEL...

Page 65: ...MT6250 User s Manual V1 3 65 Appendix Function Keys F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 Home End Enter Numeric Key App...

Page 66: ...MT6250 User s Manual V1 3 66 Appendix Navigation Keys Cursor Left Cursor Right Cursor Up Cursor Down Page Up Page Down Tab Back Tab Esc Enter BS Ins Del...

Page 67: ...1 3 67 Appendix Modifier Keys Alt Left make 1 Alt Left break Alt Right make Alt Right break Shift Left make 2 Shift Left break Shift Right make Shift Right break Win Left make Win Left break Win Right...

Page 68: ...sume barcode setting 2 When Shift Left make is programmed please scan Shift Left break to resume barcode setting 3 When Ctrl Left make is programmed please scan Ctrl Left break to resume barcode setti...

Page 69: ...d Ctrl Mode Numeric Key OFF OPOS OFF Capital Lock Mode OFF Image Settings Inverse Barcode OFF Centering OFF Interface USB HID N A Keyboard Layout English US Intercharacter Delay 0ms Interblock Delay 0...

Page 70: ...Digit Send UPC E0 to UPC A OFF EAN 8 Enable Disable ON Check Digit Send EAN 13 Enable Disable ON Check Digit Send ISBN OFF ISSN OFF UPC EAN Supplement OFF Code 128 Enable Disable ON GS1 128 Enable Di...

Page 71: ...h 50 Interleaved 2 of 5 Enable Disable ON Verification Disable CDV Min Length 05 Max Length 50 Matrix 2 of 5 Enable Disable ON Min Length 04 Max Length 24 Industrial 2 of 5 Enable Disable ON Min Lengt...

Page 72: ...V1 3 72 Enable Disable ON QR Code Enable Disable ON Micro QR Code Enable Disable ON Data Matrix Enable Disable ON PDF417 Enable Disable ON MicroPDF417 Enable Disable ON Aztec Enable Disable ON MaxiCod...

Page 73: ...Code 128 GS1 128 ISBT 128 K 4B 5 Code 39 Code32 M 4D 6 Code 93 L 4C 7 Code 11 J 4A 8 Codabar N 4E 9 Interleaved 2 of 5 I 49 10 Matrix 2 of 5 Y 59 11 Industrial 2 of 5 V 56 12 GS1 DataBar G 47 13 MSI P...

Page 74: ...Line Feed 0B 11 VT Vertical Tab 0C 12 FF Form Feed 0D 13 CR Carriage Return 0E 14 SO Shift Out 0F 15 SI Shift In 10 16 DLE Data Link Escape 11 17 DC1 XON Device Control 1 12 18 DC2 Device Control 2 13...

Page 75: ...nthesis 2A 42 Asterisk 2B 43 Plus 2C 44 Comma 2D 45 Minus Dash 2E 46 Dot 2F 47 Forward Slash 30 48 0 31 49 1 32 50 2 33 51 3 34 52 4 35 53 5 36 54 6 37 55 7 38 56 8 39 57 9 3A 58 Colon 3B 59 Semi colo...

Page 76: ...57 87 W 58 88 X 59 89 Y 5A 90 Z 5B 91 Left Opening Bracket 5C 92 Back Slash 5D 93 Right Closing Bracket 5E 94 Caret Circumflex 5F 95 _ Underscore 60 96 Grave Accent 61 97 a 62 98 b 63 99 c 64 100 d 6...

Page 77: ...6250 User s Manual V1 3 77 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7A 122 z 7B 123 Left Opening Brace 7C 124 Vertical Bar 7D 125 Right Closing Brace 7E 126 Tilde 7F 127 DEL Dele...

Page 78: ...History Rev Date Description Issued 1 0 2021 12 15 Initial Release Shaw 1 1 2022 02 22 Updated Standby Current Typical D O F Shaw 1 2 2022 07 05 Added Control Code Output Method Added MaxiCode Shaw 1...

Reviews: